Site visit or send-in evaluation
Share the full motor order code and serial number, encoder ID, drive model and alarm, and photos of the encoder label and motor connectors. Tell us whether the fault started after a bearing change, encoder swap or cable repair. Leave the original encoder in place when practical so the technician can capture the incoming alignment and memory before removal. Use the enquiry form to arrange a visit or get send-in instructions.
What specialist testing can show
With the correct EnDat setup, matched cable and Athena profile, a Mitchell TI-5000JX can check serial position and direction and read supported encoder status or memory. On a matching Festo motor, a specialist can record the electrical angle at the prescribed phase references and save the incoming memory. Confirm the exact profile and software version before interpreting or writing OEM data. For the 728563-xx mounting clearance, HEIDENHAIN lists its PWM 21 with ATS and the ExI mounting wizard. Mitchell’s Festo guidance explains that its analog Line Levels test cannot establish the gap on the serial-only feedback version. Mitchell HEIDENHAIN encoder testing · Mitchell Festo EMMS support · HEIDENHAIN mounting wizard and ID list (PDF)
Mitchell lists a TI-3000JX run test for supported Festo EMMS motors using Gen Endat Run Ser, commonly with feedback lead TI-5662 and power lead TI-3027. Match the connectors and setup to the motor. Run testing belongs on a secured, guarded fixture after feedback direction and commutation have been verified. Mitchell Festo run-test setup
HEIDENHAIN ECI 1118 technical reference
Find your ECI 1118 by full manufacturer ID
Read the ID on the encoder label, including the two digits after the hyphen. A shared model name or 15-pin plug leaves several possibilities. The exact ID selects the electrical order code, mechanical variant and connector. On an OEM motor, record the motor code, serial number and feedback option before ordering a replacement.
| HEIDENHAIN ID | Interface | Flange and shaft | Encoder connector |
|---|---|---|---|
| 728563-01 | EnDat22, digital only. 3.6–14 V DC. | 70E / 82C. Ø36.83 mm synchro flange. Ø6 mm blind bore, 2.8 mm deep. | Bent 15-pin plug, radial cable entry. D740561. Mounting sheet code 5ZS15-RL. |
| 728563-02 | EnDat22, digital only. | 70E / 82C per mounting sheet 1148241-90. | 5ZS15-RL and same six assigned pins as 728563-01. Confirm the suffix-specific difference with HEIDENHAIN. |
| 1149206-01 | EnDat22, digital only. | 70E / 82C per mounting sheet 1148241-90. | 5PS15-RL and same six assigned pins. Check the header direction and cable clearance on this unit. |
| 1164814-02 | EnDat01 plus 16 periods/rev of 1 Vpp. 4.75–10 V DC. | 70F / 82A. Ø36.83 mm synchro flange. Ø6 mm blind bore, 4 mm deep. | Straight 15-pin plug, axial cable entry. D533387. |
HEIDENHAIN lists both 728563-01 and 1164814-02 at 262,144 positions per turn. Match bore depth, mounting surfaces, plug direction, supply and drive feedback configuration before choosing a spare. HEIDENHAIN 728563-01 exact record · HEIDENHAIN 1164814-02 exact record · HEIDENHAIN 1148241-90 mounting and ID sheet (PDF)
Production and end-of-life status
As of 7 November 2026, HEIDENHAIN had catalogue records for 728563-01 and 1164814-02. Current production, last-time-buy or end-of-life status for either exact ID remains unconfirmed. Confirm orderability and an approved successor for the full ID and motor order code when planning a replacement. 728563-01 catalogue record · 1164814-02 catalogue record
Specifications
| Parameter | 728563-01 | 1164814-02 |
|---|---|---|
| Measuring method | Inductive, absolute singleturn, without an integral bearing | Inductive, absolute singleturn, without an integral bearing |
| Position output | 262,144 binary values per revolution (18 bits), EnDat22 | 262,144 binary values per revolution (18 bits), EnDat01 with 16 periods/rev of 1 Vpp |
| Supply at the encoder | 3.6–14 V DC. Typical 80 mA at 5 V, without load. | 4.75–10 V DC. Typical 85 mA at 5 V, without load. |
| Maximum normal-operation power | 0.52 W at 3.6 V, 0.60 W at 14 V | 0.60 W at 4.75 V, 0.65 W at 10 V |
| Encoder calculation time and maximum clock | ≤6 µs and ≤8 MHz | ≤8 µs and ≤2 MHz |
| System accuracy | ±120 arcseconds | ±280 arcseconds |
| Mechanical shaft speed | ≤15,000 rpm | ≤15,000 rpm |
| Flange and centering collar | Ø36.83 mm. Catalogue overall flange length 9.9 mm, collar length 2.45 mm. | Ø36.83 mm. Catalogue overall flange length 20.3 mm, collar length 2.30 mm. |
| Blind bore | Ø6 mm × 2.8 mm deep | Ø6 mm × 4 mm deep |
| Operating temperature and ingress protection | −20 to +115 °C, IP00 | −40 to +115 °C, IP00 when mounted |
Use the motor and drive limits for the assembled system. The encoder speed rating is a component limit. The motor enclosure provides the environmental protection. HEIDENHAIN 728563-xx specifications (PDF) · HEIDENHAIN 70F EnDat01 specifications (PDF)
Mounting, shaft fit and scanning gap
The ECI 1118 uses the motor bearings to hold its rotor and stator in alignment. The encoder’s blind bore sits on the motor shaft and the central screw retains the rotor. The encoder stator centers on the motor’s flange register and clamps to the mounting face. Dirt under either seating face, a loose central screw, uneven flange clamping or motor bearing play can change the scanning gap and give intermittent feedback.
- 70E / 82C, 728563-01. HEIDENHAIN sheet 1148241-90 shows the M3 × 16 A2 central screw tightened to 1.2 ±0.1 N·m for the documented assembly. Match the specified screw and locking feature, and obtain the motor maker’s final assembly instructions for the flange clamp. The mating drawing gives ±0.3 mm for the permitted shaft-to-flange seating surface deviation.
- 70F / 82A, 1164814-02. Use the EnDat01 70F drawing and the motor maker’s assembly procedure. Its Ø6 mm bore is deeper and the cable exits axially. Check the flange register, shaft shoulder, available cable space, fastener specification and clamping method for that exact motor.
Check the mounting gap separately from the serial link. A valid EnDat position reply confirms communication at the test condition. After bearing work or an encoder change, check the mating surfaces and shaft play and use the supported gap procedure before commissioning. 70E / 82C mounting sheet (PDF) · 70F mating drawing (PDF)
Interface and measuring method
The inductive scanning system senses shaft angle and produces an absolute position within one turn. With feedback power and a compatible drive, position is available at standstill. A singleturn reading repeats every revolution. Any count of completed revolutions belongs to the machine’s separate positioning strategy.
EnDat22 on 728563-01, 728563-02 and 1149206-01. The drive sends timing on the differential CLOCK pair. The bidirectional DATA pair carries commands and replies containing binary position and protocol check information. Inspect the serial communication and the position trend with a compatible drive or tester. The encoder supplies serial position only.
EnDat01 on 1164814-02. The same serial signal roles carry absolute position. This variant also supplies two quadrature 1 Vpp differential analog channels with 16 periods per turn. A drive configured for this version can interpolate the analog signals for motion feedback. It needs the correct input type, termination and EnDat setup. HEIDENHAIN EnDat and 1 Vpp interface handbook (PDF) · EnDat01 pin and signal table (PDF)
Verified wiring at the encoder and motor
Use the connector view in the matching drawing. A cable socket and its mating plug can look mirrored. Identify the housing reference marks before probing. The second pin listed for each DATA or CLOCK pair is its complement.
| PCB pin | 728563-01, 728563-02, 1149206-01 (EnDat22) | 1164814-02 (EnDat01) |
|---|---|---|
| 13 | UP, DC supply | UP, DC supply |
| 14 | 0 V return | 0 V return |
| 7 / 8 | DATA / complementary DATA | DATA / complementary DATA |
| 9 / 10 | CLOCK / complementary CLOCK | CLOCK / complementary CLOCK |
| 11 / 12 | Vacant | UP sense / 0 V sense |
| 1 / 2 | Vacant | A+ / A− |
| 3 / 4 | Vacant | B+ / B− |
| 5, 6, 15 | Vacant | Vacant |
Leave unused pins open. Keep the shield bonded as shown in the matching harness and motor drawing. 70E EnDat22 connector drawing (PDF) · HEIDENHAIN EnDat22 pin table and ECI 1118 exceptions (PDF) · 70F EnDat01 connector drawing (PDF)
| M12 pin | Function at the motor bulkhead |
|---|---|
| 8 / 5 | UP / 0 V |
| 3 / 4 | DATA / complementary DATA |
| 7 / 6 | CLOCK / complementary CLOCK |
| 2 / 1 | +SENS / −SENS |
Festo’s external M12 map labels sense pins at the motor socket. The EnDat22 ECI 1118 PCB map leaves pins 11 and 12 vacant. Use the exact motor loom drawing to confirm how Festo handles sense. For a custom loom, obtain that drawing before terminating sense or shield. Festo motor-side connector drawings (PDF)
Cables inside the motor
| Part number | Endpoints and application |
|---|---|
| HEIDENHAIN 640030-xx | In-motor output lead for the 70F EnDat01 family covered by PDF 1270494, including 1164814-02. 15-pin PCB connector to 12 open TPE wires with heat shrink. The supplied internal lead has no shield. Confirm length suffix and OEM bulkhead termination. |
| Festo 550318 NEBM-M12W8-E-5-N-S1G15 |
External 5 m encoder cable for the catalogued EMMS-AS 70/100/140/190 encoder option to CMMP-AS. |
| Festo 5213423 NEBM-M12W8-E-5-N-R3G8 |
External 5 m encoder cable for the catalogued EMMS-AS 70/100/140/190 encoder option to CMMT-AS. |
| HEIDENHAIN 621742-01 15-pin adapter 528694-02 |
Bench test lead for modular encoders to PWM 21. Confirm the adapter and interface before connecting. |
The complete internal PCB-to-bulkhead loom for a 728563-01 Festo build remains unverified. For a replacement loom, give Festo the exact motor order code, serial number and connector photos, including the lead labels and keying. Match both ends and the OEM shield termination before repair. The Festo numbers above are motor-to-drive cables. HEIDENHAIN 70F leads (PDF) · Festo cable ordering table (PDF) · HEIDENHAIN bench leads (PDF)
Fault checks you can make
Before opening or unplugging anything. Follow your site’s isolation procedure. Secure the load against movement and isolate and lock out motor power, drive mains and any separately fed control or feedback supply. Observe the drive discharge interval and verify absence of voltage, including the DC bus, using the drive manual and your site’s test procedure. A stop command or drive inhibit alone leaves electrical energy present. A qualified technician should carry out internal inspection and electrical tests.
- Connector and cable. With power verified off, check that the motor plug is fully seated and secured. Look for a backed-out pin, bent contact, cracked key, fretting, oil or debris between contacts, damaged shielding and pinched wires. Grip the plug body. Use an approved cleaning method for the connector and follow the OEM’s ESD precautions.
- Mounting. If internal inspection is authorized, look for a loose central screw or uneven stator clamping, a disturbed flange register, rubbing marks and excessive motor bearing play. Preserve the original alignment and memory before removal. Check the exact mating drawing after bearing work.
- Continuity and shorts. With the harness disconnected from the drive and encoder, use a multimeter in resistance mode. Touch the probes together to establish lead resistance. Check each conductor end-to-end using the two verified connector maps and flex the cable gently near strain reliefs while watching for an unstable reading. Then check between unrelated conductors and from signals to shield or shell. Expect an open reading where the harness drawing shows isolation. Compare intentional links, such as any sense connection and specified shield bond, with the OEM diagram. Keep insulation testers away from encoder and drive electronics.
- Supply under load. For a qualified person under an approved test procedure only. Fit a documented breakout with power off. Secure the motor and inhibit torque as the procedure requires before energizing feedback. In DC-voltage mode, place black on 0 V and red on UP. On the PCB of the IDs listed above those are pins 14 and 13. At the documented Festo M12 bulkhead they are pins 5 and 8. Use the drive’s specified feedback supply and the exact encoder’s allowable window. If the voltage is correct at the drive but falls at the encoder under load, investigate connector resistance, supply/return continuity and the sense wiring. Remove the breakout with power off.
A multimeter is useful for power and cable checks. Read position and communication errors with the drive or a compatible tester. Use an approved differential measurement setup for the EnDat pairs or the 1164814-02 analog channels.
| Symptom | Next check |
|---|---|
| No feedback after power-up | Match the encoder ID to the configured feedback type. Check the supply and return at the encoder, then verify CLOCK and DATA pair continuity and polarity. |
| Communication errors with cable motion or drive enable | Check connector retention, routing, shield termination and supply drop. Compare the fault with a known-good, exact-match lead where safe. |
| Dropout once per turn, after bearing work, or after warm-up | Check axial play, seating faces, clamping and scanning gap. Verify position over a turn using the approved test setup. |
| Stable position but poor torque or an enable trip after replacement | Check feedback direction, motor phase order, commutation offset and the OEM profile before attempting a run test. |
| Errors persist on a known-good cable and compatible tester | Verify the supply and mounting under the same conditions. If the fault follows the encoder, arrange a bench evaluation. |
Motor applications
Festo EMMS-AS-70-S-LS-RS, order number 550114. Festo specifies inductive EnDat 2.2 singleturn feedback with 18-bit resolution for this motor. Mitchell separately identifies an ECI 1118 example in EMMS-AS-70-S-RS support material. Confirm the installed HEIDENHAIN ID from the original encoder label before using the component specification or replacing it. The motor code, motor connector and drive setup are separate checks. Festo 550114 motor data sheet (PDF) · Mitchell ECI 1118 motor example
Angle of alignment and motor memory
Use the motor’s own commutation reference. Mitchell documents motor-specific alignment and nameplate data in the encoder memory of supported Festo EMMS motors. A working EnDat position reply can coexist with an incorrect offset. Record the motor and encoder IDs, drive configuration and incoming alignment before removing the original encoder. On a suitable guarded bench, Mitchell calls for recording the +U/−V and +U/−W lockup readings, with their test convention and electrical angle units.
Where supported, save an unedited original memory file and identify the sections approved for restore. For the same motor, use a compatible replacement and an OEM-approved procedure to restore the correct motor data, then read it back. Verify physical mounting, feedback direction and commutation separately before returning the motor to service. If the original memory is unreadable, use the motor serial number to obtain the approved setup or commissioning method. The encoder model name alone cannot give the motor’s angle. Mitchell Festo alignment and memory notes
Drawings, pin maps and manuals
- HEIDENHAIN mounting sheet 1148241-90 (PDF). 70E / 82C mating dimensions, central screw, connector and supported IDs. If the download redirects, request the document by number or use the product catalogue’s Downloads section.
- HEIDENHAIN Encoders for Servo Drives, 208922 (PDF). See the ECI/EBI 1100 series for 728563-xx and Mounting Diagnostics for the ExI wizard. Pin layouts include the ECI 1118 EnDat22 exceptions.
- HEIDENHAIN ECI/EQI 70F product information, 1270494 (PDF). Select the EnDat01 rows for 1164814-02. See the mating drawing, open-end lead and encoder pin layout.
- HEIDENHAIN Interfaces of Encoders, 1078628 (PDF). EnDat communication and 1 Vpp signal details.
- Festo EMMS-AS catalogue (PDF). Page 13 for motor-side pin allocation and page 40 for external encoder cables.
- Mitchell TI-5000JX training index and Festo EMMS setup notes. Motor testing, alignment and cable setup.