Site visit or send-in evaluation
Provide both label IDs, shaft size, drive details, the alarm and photos of the assembled key, flange and connector. Note if the fault repeats at a specific angle or started after installation. Use the enquiry form to share the details.
What specialist testing can show
A qualified technician can read serial position and diagnostics with a suitable EnDat system, and measure the mating geometry independently. HEIDENHAIN publishes mounting instructions and PWM 21 test accessories. Mitchell documents generic EnDat serial tests and a generic serial run method for supported motors. Confirm the exact ECI 4010 profile, assembly, lead and motor compatibility before using either tester or running the motor. HEIDENHAIN mounting and test equipment (PDF) · Mitchell EnDat testing · Mitchell RunSer guidance
HEIDENHAIN ECI 4010 Inductive Ring Encoder technical reference
Find your part number
The ECI 4010 has two orderable measuring parts. Record the AE scanning-unit ID and the TTR scale-drum ID. The 180 mm and 90 mm builds share the ECI 4010 name and 20-bit position resolution.
| AE scanning-unit ID | Model and fit | TTR scale-drum ID |
|---|---|---|
| 1087526-02 | ECI 4010 singleturn, 180 mm through shaft, drum outside Ø203.80 mm | 1113606-02 |
| 1130167-02 | ECI 4010 singleturn, 90 mm through shaft, drum outside Ø112.80 mm | 1130175-02 |
| 1097530-02 | EBI 4010 battery-backed multiturn, 180 mm through shaft | 1113606-02. Uses the EBI battery pin map. |
| 1130173-02 | EBI 4010 battery-backed multiturn, 90 mm through shaft | 1130175-02. Uses the EBI battery pin map. |
Use the document for the actual shaft and both labels. The ECI and EBI variants use different supply-contact functions. HEIDENHAIN 180 mm ID table (PDF) · HEIDENHAIN 90 mm ID table (PDF)
Production and end-of-life status
HEIDENHAIN provides an exact record for 1087526-02 and lists the ECI/EBI 4000 family. Confirm production and orderability for the separate scanning unit and drum IDs. Reviewed 7 November 2026. 1087526-02 exact record · HEIDENHAIN ECI/EBI 4000 family
Specifications
| Parameter | Value |
|---|---|
| Measurement and output | Inductive absolute singleturn, no integral bearing. EnDat22. 1,048,576 binary positions per turn (20 bits). |
| Accuracy and serial timing | ±40 arcseconds system accuracy. Calculation time ≤5 µs and encoder clock ceiling 16 MHz. |
| Supply | 3.6–14 V DC. Typical 95 mA at 5 V without load. Maximum 630 mW at 3.6 V and 700 mW at 14 V. |
| Fit | 180 mm keyed through shaft. Scanning unit ring inside Ø205.2 mm, outside Ø229 mm, Ø220 mm hole circle. Scale drum outside Ø203.80 mm. |
| Speed and temperature | ≤6000 rpm encoder limit for the 180 mm configuration. −40 to +115 °C, IP40 at scanning unit. |
| Connector | Straight 15-pin PCB, right outlet, D608296. |
Mounting and fit
The drum rotates on the motor’s centering collar. The 180 mm safety drawing shows a keyed shaft interface and the stationary scanning unit located by its external centering diameter. Confirm the shaft and stator bearing faces, coaxiality and axial relationship before assembly. Compare a repeatable dropout at the same angle with measured drum eccentricity or a contact mark.
Use the exact drawing for the press fit, key, bolt circle and tightening sequence. The 180 mm drawing specifies 2.2 ±0.13 N·m for its ISO 4762 M4×25–8.8 fastening screws with the required anti-rotation feature. HEIDENHAIN lists 202264-88 as a matching locking screw option. Confirm the motor’s material and mounting conditions, and restore the specified guard before operation. A safety-axis mounting change requires the applicable revalidation. 180 mm mating and assembly requirements (PDF)
Interface and measuring method
The scanning unit senses the angle of the rotating drum inductively. The controller sends differential CLOCK and receives binary position and status through the bidirectional DATA pair. This ECI EnDat22 build reports one turn. The EBI version uses a separate battery circuit for the multi-turn function. A serial count at standstill checks link operation and leaves the mounting geometry and full-turn behavior to be verified.
Verified wiring
Use the ECI table in the exact 180 mm PDF. The M23 and M12 assignments below apply to the documented HEIDENHAIN external connections. Use the drawing’s connector face and housing marks.
| Function | 15-pin PCB | M23 9-pin | M12 8-pin |
|---|---|---|---|
| Uₚ / 0 V | 13 / 14 | 3 / 4 | 8 / 5 |
| Supply sense / return sense | 11 / 12 | 7 / 8 | 2 / 1 |
| DATA / complement | 7 / 8 | 5 / 6 | 3 / 4 |
| CLOCK / complement | 9 / 10 | 1 / 2 | 7 / 6 |
| External temperature sensor T+ / T− | 5 / 6 | Separate sensor routing | Separate sensor routing |
Keep unused pins vacant. The EBI table assigns battery and battery return to contacts 11 and 12 instead of sense. Confirm the OEM bulkhead and shield before connecting either version. HEIDENHAIN ECI and EBI pin layouts (PDF)
Cables inside the motor and at the machine
| ID | Endpoints |
|---|---|
| 1120940-30 | 0.3 m, 15-pin PCB to 9-pin M23 SpeedTEC angled male flange, with separate sensor wires |
| 1121041-03 | 0.3 m, 15-pin PCB to 9-pin M23 SpeedTEC angled male flange. Check the assembly and temperature specification. |
| 1287818-01 | 1 m, 15-pin PCB to 8-pin M12 male coupling |
| 745796-xx | External M23-to-M12 connecting cable option in the same document |
These are catalogue cable assemblies. Confirm the motor’s actual harness, length and temperature range. Use the approved assembled lead in a safety-related system. HEIDENHAIN cables, connectors and temperature notes (PDF)
Fault checks
Lock out the drive and secure the axis before removing the cover. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect mechanical fit. Check ring and unit IDs, key, bearing faces, concentricity, rubbing marks, loose fasteners and cable clearance. A shifted drum or carrier can give a fault only in part of the revolution.
- Inspect the connector and isolate the lead. Check pin condition, retention, debris and shield. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics.
- Check supply and serial pairs. With an approved breakout fitted while off, a qualified person can measure supply at pins 13 and 14 of the ECI PCB. Compare drive and encoder ends under load. Check DATA/CLOCK with a suitable diagnostic instrument after confirming the correct EnDat profile.
- Read the failure pattern. No serial response points first to supply or wiring. A dropout in the same angular region calls for an installed geometry check. Stable count with a new torque or safety fault calls for checking direction, offset and the commissioned device combination.
Motor and drive applications
The 180 mm and 90 mm ECI 4010 assemblies are intended for compatible large-through-shaft installations. An exact OEM motor code and replacement assembly require the equipment builder’s drawing. The encoder document supplies the device-side geometry and connection for the identified parts. HEIDENHAIN 180 mm assembly (PDF) · HEIDENHAIN 90 mm assembly (PDF)
Angle of alignment and commissioning
Center the ring and scanning unit using the exact assembly drawing, then verify position through a full turn. Preserve the existing machine zero and drive settings before removal. On a motor-controlled axis, check the OEM electrical-angle reference separately and restore any approved settings only to the documented motor. A functional-safety installation also needs the manufacturer’s validation after mechanical or feedback changes.
Drawings, pin maps and manuals
- HEIDENHAIN 1214288 ECI/EBI 4010 180 mm (PDF). Matched IDs, fit, safety assembly, cables and ECI/EBI pin layouts.
- HEIDENHAIN 1140717 ECI/EBI 4010 90 mm (PDF). Separate parts and dimensions for the 90 mm build.
- 1087526-02 exact HEIDENHAIN record. Mounting and pin drawing numbers in the Downloads section.
- HEIDENHAIN Encoders for Servo Drives (PDF). Mounting principles for the ECI/EBI 4000 series and test accessories.