Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
An EnDat-capable bench can read identification and stable position and evaluate the analog tracks where the fixture supports them. Mitchell documents the ECN 1113 family on TI-5000JX with TI-5668 for direct connection. A powered TI-3000JX run needs a separately verified motor setup.
HEIDENHAIN ECN 1113 803427-01 EnDat01 Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 803427-01. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| ECN 1113 · 803427-01 | 1KA 6 mm blind hollow shaft and 75A recessed face coupling. | Singleturn EnDat01 and 512 analog periods per turn. Double-row R8 PCB plug. |
| EQN 1125 · 803428-01 | Related ECN/EQN 1100 mounting family. Check the exact drawing. | Adds multiturn position. A similar plug and signal class do not establish replacement compatibility. |
| ECN 1123 · 803429-01 | Related 1100 family. Verify the motor mating drawing. | EnDat22 without the ECN 1113 analog track output. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute positions | 8,192 per revolution, singleturn, binary. |
| Incremental output | 512 sin/cos periods per revolution, nominal 1 Vpp. −3 dB cutoff 190 kHz. |
| Supply | 3.6–14 V DC at the encoder, exact ID product record. |
| Coupling and bore | 75A, M3 on Ø43 mm pitch circle. 1KA Ø6 mm axial-fastened blind hollow shaft with a 2 mm drive lug protruding 2.6 mm. |
| Connector and environment | Straight double-row 15-contact R8, map D533387. IP40. Operating −40 to +115 °C. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Inspect the motor pilot, drive lug, shaft end and coupling face for burrs, fretting and signs of slip. The lug locates the rotor and the flexible stator coupling restrains the housing while accommodating the specified movement.
Use the mating drawing for the 1KA and 75A combination and the motor service instructions for the fastener, preload and tightening sequence. Avoid using the stator screws to pull a reluctant rotor into place.
Interface and measuring method
The receiver reads absolute position over the EnDat clock and data lines. The paired analog tracks also let compatible electronics interpolate motion between the 512 periods.
If the drive can read position but reports loss of speed feedback, check whether it uses the analog tracks. If the analog tracks look plausible but absolute position cannot be read, trace the clock and data path separately.
Verified wiring
At the 15-contact R8 device header use HEIDENHAIN map D533387 as indexed by 803427-01. Match the drawing view and key before identifying supply and return, clock pair, data pair and the two analog pairs.
The published product page identifies the map but its direct download currently redirects. Obtain the map or the motor builder’s verified connector drawing before probing individual contacts. The motor bulkhead has its own map.
Cables inside the motor and at the machine
HEIDENHAIN lists 606079-01 and 605090-xx in the ECN 1113 / EQN 1125 JAE output-cable catalogue. These are catalogue assemblies for the documented topology. Match the R8 termination, length and motor bulkhead to the machine drawing.
Mitchell lists TI-5668 at the encoder for the ECN 1113 and EQN 1125 in its MOOG coverage. Identify the connector on the motor before selecting the separate motor-side lead.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Position is present but unstable while moving | Check both analog pairs using the approved receiver or differential measurement. Inspect the lead restraint and shaft seating. |
| No serial response with clean analog tracks | Check the receiver’s EnDat mode, the clock/data path and supply at the correct ends. |
| Feedback changes after remounting | Check lug seating, stator coupling and the original motor commutation reference before enabling motion. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Mitchell identifies ECN 1113 on some MOOG servo motors. Record the full MOOG motor order and drive feedback option before using that example. The HEIDENHAIN ID alone does not establish which motor is fitted.
Angle of alignment and commissioning
Record the original rotor-to-encoder relationship and capture supported OEM position data before removal. Re-establish the motor-specific commutation reference by the manufacturer’s procedure. There is no universal ECN 1113 angle.
Drawings, pin maps and manuals
- Main technical PDF. ECN 1100 series comparison and mating geometry. Use the exact ID page for the 803427-01 configuration.
- Manufacturer reference. Match the exact order code or the identified motor option.
- Mitchell MOOG motor guide. Documents ECN 1113 and the direct TI-5668 lead.
- HEIDENHAIN cable catalogue. See the EnDat01 output-cable table for ECN 1113 (JAE).
- EQN 1125 803428-01. Check the multiturn comparison.
- ECN 1123 803429-01. Check the distinct EnDat22 version.