Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A correctly loaded 1 Vpp receiver or approved HEIDENHAIN diagnostics can compare signal amplitude, phase and reference across travel. Confirm the adapter, supply and exact profile before any Mitchell setup. Treat the machine's reference run as a separate qualified commissioning operation.
HEIDENHAIN LB 383C 1313984-22 Sealed 1 Vpp Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 1313984-22. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 1313984-22 | LB 383C one-piece, mirrored fastening, 1,840 mm measuring length. | 40 µm grating, 1 Vpp and distance-coded reference marks. |
| 1313984-01 | LB 383C one-piece, 440 mm measuring length. Confirm the housing drawing for the ID. | 1 Vpp and distance-coded marks. The short unit has different travel. |
| 1313982-13 | LB 383 one-piece, standard fastening, 2,840 mm measuring length. | 1 Vpp with a reference mark in the middle instead of the C distance-coded scheme. |
Production and end-of-life status
HEIDENHAIN lists exact ID 1313984-22 on the product site. Confirm production and orderability with HEIDENHAIN. The exact mating and mounting downloads redirected to its maintenance notice during review.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring length | 1,840 mm for 1313984-22. Overall housing length and mounting dimensions are separate. |
| Fit | One-piece sealed scale housing, mirrored fastening. Use the exact mating drawing and measuring-start mark. |
| Grating and signal | 40 µm grating and sinusoidal 1 Vpp. Accuracy grade ±5 µm. |
| Supply | 5 V DC +5%/−10%, 4.50–5.25 V from the exact product data. Verify at the designated measurement point. |
| Reference | Distance-coded reference marks, nominal spacing convention 2,000 grating periods for this record. |
| Electrical connection | Separate adapter cable, not specified by the main encoder ID. Identify its code and both ends. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Check measuring length, housing length, mirrored fastening and scale start against the axis drawing. Install the housing on the machine's specified mating surfaces. Align the scanning unit bracket using the prescribed mounting aid and verify travel and cable clearance. Mounting aid ID 824039-01 is listed in the family brochure for LB 383. Confirm its use for the installation.
Read the exact seal and purge-air instructions if used. Inspect the housing, scanning-head bracket and cable clamps after isolation. Use the OEM procedure for any scale-tape work or adjustment.
Interface and measuring method
The controller interpolates two 1 Vpp analogue incremental signals to track movement relative to the grating. The separate reference track lets a compatible control determine the machine reference from consecutive distance-coded marks. A clean incremental signal can coexist with reference failure if the control expects a single mark or the reference channel is damaged.
Verified wiring
The exact product record identifies a separate adapter cable. Use its label and the matching HEIDENHAIN cable drawing to establish the connector view and map. The 1 Vpp interface brochure identifies A, B, reference, supply and sense as applicable. Compare these functional paths with the actual adapter and control drawing before measuring or moving wires.
| Path | What to verify on the exact adapter drawing |
|---|---|
| Power | UP, 0 V and any supply or return sense conductors. |
| Incremental | Separate A and B differential pairs. |
| Reference | R differential pair and distance-coded capture in the control. |
| Shield | Documented housing and connector termination. |
Cables inside the motor and at the machine
Read the scanning-head adapter label, connector type and cable length. The scale ID does not select the control-side connector. Source the exact adapter from the HEIDENHAIN cable catalog or machine BOM. Check any extension and sense treatment on the complete drawing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No position feedback | Check the adapter, supply at the approved point and both 1 Vpp incremental pairs under the specified input load. |
| Incremental count present, homing fails | Check the reference track and distance-coded setup. Confirm the installed LB 383C ID. |
| Intermittent position at one travel point | Inspect bracket position, housing and cable movement in that area. Compare the signal envelope through travel. |
| Error begins after scale swap | Compare measuring length, mirrored fastening, grating and reference configuration with the original label. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the exact 1313984-22 guide on compatible machine-tool axes. Compare the measured axis geometry and controller reference method before exchanging with the standard-fastening LB 383. The encoder's measuring length is the useful position span.
Angle of alignment and commissioning
Set scale and scanning-head geometry to the installation drawing. After service, carry out the specified reference run and verify position, direction and repeatability within the OEM acceptance criteria. No motor commutation angle is required for this scale itself.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- HEIDENHAIN interface brochure. Use the 1 Vpp signal and loading section.
- Exact mating-dimension reference 1329868-02. HEIDENHAIN linked this download from 1313984-22. It redirected to a maintenance notice during review.
- Single-section mounting reference 1338769. Linked by the exact product record. Download redirected during review.
- LB 383C 440 mm exact record. Compare measuring length and fastening.
- LB 383 2840 mm exact record. Compare the standard fastening and centre reference mark.