Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Read the CNC encoder diagnostics first. A bench evaluation needs an EnDat22 reader with the documented 14-pin cable and a suitable fixture for relative travel. Verify reported position, communication errors and consistency across travel. Confirm exact Mitchell profile and cable support before using the Mitchell equipment on this scale.
HEIDENHAIN LC 415 EnDat Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 689676-17. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 689676-17 | 920 mm measuring length, 1,058 mm overall by the catalogue formula. 12A end block and mounting spar. | EnDat22, male 14-pin flange socket, 3.6–14 V DC. |
| 689676-18 | 870 mm measuring length, 1,008 mm overall. Same end-block family. | Same interface designation. Shorter usable measuring length. |
| 689676-02 | 120 mm measuring length, 258 mm overall. Same end-block family. | Same interface designation. Verify actual machine stroke before sourcing. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring length / housing length | 920 mm / 920 + 138 = 1,058 mm. Allow separate clearance for the connector and cable bend. |
| Accuracy grade / measuring step | ±5 µm / 10 nm. Resolution describes the reported step and accuracy describes the stated position error. |
| Grating / speed | 20 µm / up to 3 m/s for this ID. |
| Connection | 3.6–14 V DC at the scale, male 14-pin flange socket. EnDat 2.2 absolute binary position. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Start with drawing 1185025-01 for the LC 4x5/4x6 mounting family, then select the 12A arrangement in the assembly instructions. Fix the spar and scale to the specified stationary surface and the scanning unit to the translating member. Compare the machine's full travel with the usable measuring length and the permissible position of the scanning unit at both ends.
Check mounting straightness, clearance for the cable and the condition of the sealing lips on an isolated axis. Use the assembly instruction to set scanning unit position and tightening. Keep the transport or setup fixture until the instructions call for removing it.
Interface and measuring method
The CNC requests an absolute position over EnDat 2.2 using a synchronous clock and bidirectional data. The device reports position along its glass scale. This EnDat22 build omits incremental analog channels. A data fault and an implausible position are different observations and lead to different checks.
Verified wiring
The exact-ID record confirms a male 14-pin flange socket and 3.6–14 V DC. Obtain the HEIDENHAIN connection drawing for the actual scale-to-control cable and verify the mating face and numbered contacts at each end. The mating-dimensions PDF is a mechanical drawing. Connector contact numbering and supply/sense connections require the corresponding electrical drawing.
For a loaded voltage check, the qualified technician uses the approved breakout and the documented supply and return at the encoder. Record the voltage during the alarm if the machine's safe diagnostic mode permits it.
Cables inside the motor and at the machine
This is an external CNC axis scale. Match the 14-pin encoder socket, control connector, cable length, motion rating and shielding. The OEM machine cable or HEIDENHAIN cable order code is needed before specifying a replacement. A mechanically fitting plug can carry a different electrical assignment.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No EnDat device detected | Check the CNC's configured interface, the exact cable, supply at the scale and documented data and clock paths. |
| Fault repeats at one axis location | Under safe access inspect scale mounting, contamination at the seals and cable flex at that position. Separate a fixed-position optical fault from a cable carrier bend. |
| Position changes smoothly but is offset | Check axis preset, direction and the machine datum using a certified reference before adjusting compensation. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on a CNC or other linear axis with a compatible EnDat receiver. Verify axis input type, interpolation or scaling configuration and controller diagnostic support in the machine manual.
Angle of alignment and commissioning
Align the scale and scanning unit mechanically, then restore the machine datum and any verified axis compensation. LC 415 reports linear position. Motor commutation belongs to the motor's own feedback system. Save the control's axis settings before replacement and validate reference and limits under the OEM commissioning procedure.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Alternate length 689676-18. Exact manufacturer record.
- Alternate length 689676-02. Exact manufacturer record.
- Mounting instructions via Downloads / CAD / Mounting. Select LC 415 / 485 / 495, end block 12A, document 1469030. The checked direct link redirected to a maintenance notice.