Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell documents C/D and incremental checks for this setup.
TI-3000JX motor run. Mitchell lists compatible Siemens builds in Generic Incremental mode. Use the run-specific setup.
HEIDENHAIN RON 3350 1 Vpp Encoder technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| RON 3350 | 1 Vpp incremental tracks with sin/cos commutation in Mitchell’s Siemens example. |
| RON 350 | Related Siemens feedback in the training manual. The RON 350 comparison lacks the C/D tracks. |
| ERN 1387 | Another documented 1 Vpp commutation encoder. Confirm mechanical fit and ID separately. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Position | 2,048 periods per revolution from Mitchell’s 8,192 quadrature count reference. |
| Commutation | C and D sin/cos channels, one electrical signal period per encoder revolution in the documented setup. |
| Reference | Separate Z reference pulse used in the Siemens alignment workflow. |
| Exact build | Check the full HEIDENHAIN ID before choosing a mounting or supply specification. |
Mounting and fit
Inspect the installed shaft engagement, housing restraint and cable exit with the motor isolated. Match the shaft and stator mounting drawing to the full HEIDENHAIN ID. An ERN 1387 signal match alone does not establish mechanical interchangeability.
Interface and measuring method
A and B report fine angular motion. C and D provide the once-per-turn commutation signal and Z marks the reference. A smooth C/D angle can coexist with a weak incremental pair or a missing reference pulse.
Wiring and connector scope
Treat the encoder’s internal connector and the Siemens bulkhead as separate connections. Use the RON 3350 drawing for the fitted ID and the Siemens connector drawing for the actual motor. Identify A/B differential pairs, the reference and C/D before connecting a breakout.
Cables inside the motor and at the machine
TI-5010 is a Mitchell test lead for the documented Siemens connection. The internal loom part number depends on the motor build. Record the motor order and connector key before sourcing it.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| C/D angle is smooth but position counts jump | Compare A and B at the approved receiver and inspect the external feedback harness. |
| Count tracks are healthy but the reference never appears | Check the Z path and documented test adapter before changing alignment. |
| Feedback fault follows a cable swap | Check the connector view and key. Compare the motor drawing against the fitted loom. |
Motor and drive applications
Siemens 1FT6 Check the exact ID, drive and connector before applying an installation or test procedure.
Separate the incremental signals from the once-per-turn commutation signals. Confirm the full encoder ID and motor connector.
Angle of alignment and commissioning
Record the existing reference and commutation before removing the encoder. Mitchell uses Normal Commutation mode for the Siemens reference check and a separate C/D measurement. Obtain the motor-specific reference and securing procedure before adjustment.
Drawings, pin maps and manuals
- HEIDENHAIN training chapter. Overview. RON3350 on Siemens 1FT6 and TI-5010.
- Mitchell Siemens run tests. Additional application or test reference.
- Mitchell incremental encoder training. Sin/cos commutation section covers RON 3350 and bench scope.
- HEIDENHAIN PWM 8 manual. Adapter overview identifies RON 3350 and the 1 Vpp / Z1 arrangement.