What specialist testing can show
TI-5000JX bench. Check the scoped serial frame and position. Test sine/cosine where the fitted order includes those outputs.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. Match the exact AD35 connector, supply and approved BiSS fixture.
Hengstler ACURO AD35 BiSS Singleturn Absolute Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AD35 BiSS | Singleturn absolute feedback. Confirm the precise serial mode and word width from the label and drawing. |
| AD350022AF0RBIB | Hengstler order example. Use its own product record to cross-check the complete label. |
| AD35 SSI | Separate interface in the same envelope. Match data format and controller before replacing. |
Production and end-of-life status
Hengstler maintains AD35 product records and technical downloads. Check availability for the full order and output option.
Specifications
| Parameter | Verified scope |
|---|---|
| Envelope | 8 mm hub shaft and 23.65 mm mounting depth in the family catalogue. |
| Position | Up to 22 bits per turn, depending on the full order. |
| Outputs | BiSS or SSI, with 1 Vpp tracks where the option includes them. |
Interface and measuring method
The controller reads a serial frame containing angular position. Confirm the selected BiSS mode and the expected frame width. Use the analogue tracks only where the fitted order has them.
Mounting and fit
Compare the hub, shaft shoulder, locating face and cable clearance to the AD35 drawing. Record the original rotor and housing orientation before removing the encoder.
Wiring and connector scope
Use the AD35 data-sheet pin view for the actual connection. Identify supply and return, differential clock/data and optional analogue pairs. Check the drive connector separately.
Internal motor and machine cables
Record any encoder pigtail and the machine harness as separate assemblies. Confirm orientation and cable strain relief at the compact PCB connection.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| No position reply | Check supply and the BiSS setting and clock/data polarity. |
| Position jumps at a repeated value | Compare frame width and controller decode with the fitted order. |
| Dropout after refitting | Inspect hub seating and cable clearance. |
Angle of alignment and commissioning
Save the original direction and mechanical reference. After fitting, verify a known position and the expected travel before re-establishing the machine datum.
Motor and drive applications
Compact motor feedback with the documented AD35 BiSS order
Match the compact 8 mm hub and BiSS order before substituting a related ACURO encoder.
Drawings, pin maps and manuals
- Hengstler Encoders. Absolute Encoders table, AD35 and Hengstler BiSS example order table
- Hengstler ACURO AD35 and datasheet downloads. Supplementary reference for the stated model or setup.
- BiSS Serial Protocol and Hengstler option examples. Reference for the fitted feedback or motor option.
- Hengstler AD35 data sheet. Mechanical, interface option and PCB pin tables. Confirm the revision for the actual order.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation