Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell names AX65 SSI at family level. Exact setup open.
TI-3000JX motor run. Standalone encoder. Motor run test not applicable.
Hengstler AX65/1612EL.72SG1 0569024 SSI Multiturn Encoder technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| AX65/1612EL.72SG1 | Exact SSI Gray model. |
| 0569024 | Manufacturer item. The manufacturer record marks this item obsolete. |
| AX65 CANopen | Different feedback option from the same family. Use its own wiring and service record. |
Production and end-of-life status
Hengstler marks item 0569024 obsolete. Obtain a manufacturer-approved equivalent and check the exact certification, mounting and SSI data format before ordering.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | SSI Gray with RS-422 clock/data on item 0569024. |
| Resolution | 12-bit singleturn and 16-bit multiturn on the exact item. |
| Supply | 10–30 V DC on the exact item. |
| Shaft and entry | 10 mm solid shaft, clamping flange and radial M20 × 1.5 cable entry. |
Mounting and fit
Verify the 10 mm solid shaft, coupling, clamping flange and cable entry against the exact AX65 drawing. Record the full certification plate before selecting a replacement. For hazardous-area work, use qualified personnel and the manufacturer’s certified installation and repair instructions.
Interface and measuring method
The controller sends an SSI clock and reads a Gray-coded position word. A stable response can still produce the wrong position if the receiver uses the wrong code, bit length or count direction.
Wiring and connector scope
Use the AX65 SSI terminal drawing for 0569024. Confirm supply, clock and data polarity separately. Hazardous-area gland, shield and bonding requirements come from the applicable installation and approval documents.
Cables inside the motor and at the machine
The installed cable and gland are part of the certified assembly. Mitchell names AX65 SSI as a family. Confirm the exact bench fixture and permitted service location before energizing the encoder.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| Stable but incorrect position word | Check Gray decoding, singleturn/multiturn widths and preset against the exact label. |
| Readout stops with cable movement | Arrange approved inspection of the isolated terminal and cable assembly. |
| Replacement unit uses a different suffix | Check interface and approval markings before treating the replacement as equivalent. |
Motor and drive applications
Standalone encoder. Application-specific mounting. Check the exact ID, drive and connector before applying an installation or test procedure.
Match the SSI suffix and verify the hazardous-area approval and exact documentation. Hengstler lists 0569024 as obsolete.
Angle of alignment and commissioning
Record the controller’s preset, direction and travel limits. After replacement, confirm indicated position at known safe references using the machine’s procedure. Preserve the exact approval configuration.
Drawings, pin maps and manuals
- Hengstler family guide. Absolute Encoders. AX65 SSI entry and separate unsupported CANopen entry.
- Hengstler item 0569024. Exact SSI Gray configuration, ratings and obsolete status.
- Hengstler AX65 family. Compare mechanical and certification references for the chosen version.