Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A fixture with documented input loading can verify each output and the complete Gray sequence over one turn. Check mechanical repeatability separately. Verify any tester adapter before claiming Mitchell support.
JTEKT Koyo TRD-NA1024NWD Parallel Gray-Code Absolute Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TRD-NA1024NWD. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TRD-NA1024NWD | 8 mm solid shaft and 2 m pigtail cable. | 1,024 singleturn positions, parallel Gray, NPN open collector. |
| TRD-NA family | Other position counts and output configurations appear in the documentation. | Match number of bits, NPN/PNP circuitry, shaft and cable before considering a replacement. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Positions | 1,024 within one revolution. Ten output bits. |
| Output | Parallel Gray code. NPN open-collector output for the exact NWD item. |
| Supply | 10–26 V DC on exact model cut sheet. |
| Mount and cable | 8 mm solid shaft, 2 m pigtail and IP65 per the exact model sheet. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Check the shaft fit and mounting pattern from the exact cut sheet. Use the correctly aligned coupling and prevent the encoder bearing from carrying side load. Secure the pigtail where it enters the stationary housing.
Interface and measuring method
Each output wire carries one bit of the singleturn Gray word. Adjacent positions change one bit at a time. The PLC must use the correct bit order and electrical polarity and convert Gray to the desired numeric value. Log the raw word before changing PLC scaling.
Verified wiring
The TRD-NA manual’s 1024-position wiring column maps the pigtail. Follow the NPN output circuit and PLC input common in the machine drawing.
| Contact or group | Function |
|---|---|
| Brown / blue | Encoder supply / 0 V. |
| Black, red, orange, yellow, green | Gray bits 0 through 4 in order. |
| Purple, gray, white, black/white, red/white | Gray bits 5 through 9 in order. |
| Orange/white | Unused for the 1024-position column. Confirm insulation and harness drawing. |
| Shield | Apply the documented shielding scheme at the machine. |
Cables inside the motor and at the machine
The encoder has a fixed pigtail. Record the junction terminals and PLC input channel order. A 10-bit Gray word needs all ten conductors and the correct supply, reference and input circuit.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| One part of the revolution gives repeated numbers | Log raw bits and check the input with the highest suspect weight. Confirm the isolated wire and input circuit. |
| Count runs backward or jumps | Check bit order, polarity and PLC Gray decoding against several known positions. |
| All bits appear high or low | Check supply, 0 V/common, PLC input type and loads before diagnosing the device. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on machine position axes with a compatible NPN discrete input bank or encoder interface. Record the PLC card and logical mapping. No servo commutation interface is implied.
Angle of alignment and commissioning
Mark shaft and machine datum before removal. Recheck direction, position word and the machine’s zero logic after installing it. Confirm the one-turn wrap behavior during commissioning.
Drawings, pin maps and manuals
- Main technical PDF. JTEKT/Koyo TRD-NA operation manual, AutomationDirect mirror. Read the 1024/720 column and connection circuit.
- Manufacturer reference. AutomationDirect exact JTEKT item record. Use the JTEKT-authored manual for wiring.
- Exact TRD-NA1024NWD cut sheet. Supply, shaft, cable and output option.