Encoder and resolver technical library
KEBA / LTi LST-158-5 / G6.1S SRS50 Feedback | Technical Guide | Service Visit for Installation, Repair, Alignment
KEBA / LTi LST-158-5 / G6.1S uses the documented SRS50 singleturn classic HIPERFACE option. This guide helps identify the fitted feedback, distinguish an encoder fault from a cable or setup issue, and prepare a scoped UAE site visit or send-in evaluation for installation, repair and alignment.
Identification · Testing scope · Fault checks · Drawings and manuals · Service enquiry
Identify the fitted configuration
| Item | Documented scope |
|---|---|
| Manufacturer / motor base | KEBA / LTi LST-158-5 |
| Selected OEM feedback option | G6.1S — SRS50, singleturn classic HIPERFACE |
| Identifier scope | Motor base plus feedback selection; not a complete motor order. Confirm every fitted suffix. |
| Braked representative | B — 24 V holding-brake option |
| Service reference | TCG1461 — SpareFaber reference, not an OEM part number |
Confirm the complete motor order, encoder suffix/serial, drive model and connector revision. The catalogue connects this base and option to the named feedback family; an exact Mitchell entry for this motor was not found in the reviewed material. That does not prevent scoped testing of the positively identified feedback.
Specialist feedback testing
TI-5000JX: identified SRS50 / SRM50 classic HIPERFACE feedback. Evaluate serial position and analogue signals; retain incoming alignment/memory.
Starting connection: TI-5069 direct to verified SRS/SRM 8-pin encoder plug; TI-5104 after label/supply check. Motor-bulkhead adapter is not established by this proposal.
Match the actual encoder selection and lead in the installed Athena software. Check identity/status and serial position, then evaluate the analogue path separately. A clean position count alone does not prove correct analogue amplitude or installed commutation alignment. Record the equipment, cable, software version and fitted encoder label with the result; no minimum firmware version is asserted for this exact assembly.
TI-3000JX motor-run scope: Unestablished for this exact motor. Confirm motor parameters, fixture, phase order, brake, alignment and installed TI-3000JX profile before run testing.
The MOOG reference is used only because it documents the identified encoder families and their direct connectors. It does not authorize a MOOG motor profile, machine cable or alignment value for this application.
Signals and specifications
| Parameter | Documented value / boundary |
|---|---|
| Interface | Classic HIPERFACE: serial RS-485 position plus analogue sine/cosine paths |
| Serial position per revolution | 32,768 positions (15 bits) |
| Analogue periods per revolution | 1,024 sine/cosine periods; not drive-scaled counts |
| Multi-revolution information | Singleturn; no retained multi-revolution count |
| Feedback supply | 7–12 V DC in the scoped OEM table; verify the fitted encoder label |
| Brake selection | B — 24 V holding-brake option |
| Catalogue stall torque | 35 Nm; winding/speed suffix remains unspecified |
| G6.1x motor length with brake | 451 mm, catalogue p.97; shaft and connection options still need matching |
| Holding brake | 24 V DC option B; 36 Nm catalogue braking torque, ±10%; p.97 |
| Motor power / speed order | Not assigned by this guide; read the complete nameplate |
Analogue periods, serial positions, multi-revolution range and drive-scaled counts are different quantities. Do not multiply a catalogue period count into an assumed controller resolution. Feedback supply, motor DC-link/drive supply and brake supply are also separate circuits.
Mechanical fit and retention
35 Nm catalogue stall torque. G6.1x length with brake: 451 mm (p.97); verify full ordered connection and shaft options.
The G6.1x braked length is a motor-housing dimension, not an encoder body length or shaft dimension. The p.97 drawing contains the flange, pilot and shaft arrangement; compare the exact shaft/connection selection before installation. Use the frame-specific drawing; do not borrow flange or shaft dimensions from a different LST size.
Record the encoder locating seat, coupling, anti-rotation support and installed cable route before loosening any retention. Exact internal fastener torques, encoder air gap and fitted loom number are not established for every special build. Obtain the applicable assembly information before replacement.
Wiring and connector boundaries
KEBA catalogue p.115 distinguishes the 17-pin M23 optical-encoder socket from the 12-pin resolver socket. Use the G6.x column below and the original connector drawing to establish view and keying.
| OEM motor feedback contact | Signal / scope |
|---|---|
| 1 / 2 | A+ / A− |
| 3 / 4 | B+ / B− |
| 7 | GND / 0 V |
| 9 | VCC 7–12 V / 100 mA |
| 10 / 11 | DATA+ / DATA− |
| 8, 12, 13, 16, 17 | Not used for G6.x in this table |
| 5, 6, 14, 15 | Not connected |
In the adjacent SSI/EnDat column, pin 8 is +5 V and separate clock/sense contacts are present. Those assignments do not belong to G6.1S/G6.1M. Do not bridge pins 8 and 9 or substitute the neighbouring table. Match the complete S/K connection option and motor power/brake drawing independently.
Use the original drawing to confirm contact view, keying and revision before wiring. No pin assignment here is a terminal-block map for the Mitchell tester.
Internal, machine and test cables
TI-5069 direct to verified SRS/SRM 8-pin encoder plug; TI-5104 after label/supply check. Motor-bulkhead adapter is not established by this proposal.
The direct-to-encoder lead is an internal bench connection. The motor bulkhead connector, machine extension and drive-end connector form separate interfaces. No verified internal loom or complete machine-cable part number is established for this exact full order. Record both-end connector photos, cable markings, routing and required length before selecting a replacement harness.
Check the manufacturer drawing and current Mitchell lead sheet together before adapting a connection. A compatible communication protocol does not make a physical plug or pinout interchangeable.
Practical fault checks
Before physical checks, secure the driven load, isolate and lock out relevant energy sources, observe the specified discharge time and have a qualified technician verify isolation. Disconnect both cable ends before continuity or short checks and account for intentional shield bonds. Powered measurement, rotation, brake release and alignment require the applicable specialist procedure.
| Symptom | Useful next check |
|---|---|
| No serial position or incorrect encoder identity | Verify the fitted model and software choice, approved supply and serial pair, then inspect connector seating and cable condition. Separate cable and encoder tests before replacing the sensor. |
| Serial position reads but analogue path is weak or noisy | Confirm the correct sine/cosine pairs and source amplitude using the approved signal test. Inspect shielding, contamination and cable damage; an incrementing serial count does not clear the analogue channels. |
| Position or direction changes after refitting | Compare full feedback option, drive scaling/direction, preserved offset and mechanical reference. Do not copy an offset from a similar motor. |
| Fault follows cable movement | With the installation isolated, inspect strain relief, pin retention, moisture and both-end cable continuity against the actual wiring drawing. |
| Motor will not turn or reports a run fault | Check load/brake condition and the separately approved motor-run setup. A feedback pass does not prove correct brake release, winding connection or phase order. |
Incoming alignment, offsets and memory
Before loosening, removing, resetting or programming the feedback, record the incoming mechanical reference, supported commutation/alignment reading, motor pole count, direction and phase convention. Preserve drive offsets and parameters with readable encoder identity, memory/status and offset data. Tie the record to the motor and encoder serials and the test setup.
Retain or reproduce a valid incoming alignment under the applicable specialist method, then verify it after refitting. Memory retention alone does not prove physical alignment. Where motor-specific memory decoding is unavailable, keep readable data without labelling a raw backup as a verified alignment value.
If the feedback was already disturbed, the reference is invalid, or memory is absent/corrupt/unreadable, record that limitation and obtain the motor-specific recovery method. No universal angle, automatic recovery, or default transfer from another motor is established here. Confirm hardware, data format and the complete motor order before any memory write.
For this singleturn SRS50 branch, the encoder identifies position within one revolution; machine-level multi-revolution referencing is a separate control function.
Production and replacement status
The readable primary catalogue is KEBA document 0814.25B.8-00, 11/2022, hosted by its distributor Parkem. The KEBA motor page still links an LSN/LST catalogue, but the current official PDF endpoint could not be read in this review. Exact-order availability and the latest revision remain unconfirmed; verify the full motor and feedback labels before ordering.
Motor applications and related guides
G6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names.
Related pages below provide additional identification context. A related guide is not a replacement or compatibility approval for this complete motor order.
Drawings and primary documents
- KEBA LSN/LST Servomotors Order Catalogue, 11/2022 — OEM-authored, distributor-hosted copy. K1 p.14 Table 1.3 (device/fit); pp.66–67 (codes/brake); p.71 Table 3.15 (base); p.97 (G6.1x braked dimensions); p.115 (G6.x connector).
- KEBA synchronous servo motor page — Current manufacturer page and LSN/LST catalogue download entry
- Mitchell: SICK Stegmann HIPERFACE Serial Encoders — Connection, Testing, Commutation, Memory Status and Memory Test
- Mitchell: MOOG Motors — Stegmann Absolute Encoders: SRS/SRM device-level direct-lead evidence
Exact application evidence: K1 p.14 Table 1.3 (device/fit); pp.66–67 (codes/brake); p.71 Table 3.15 (base); p.97 (G6.1x braked dimensions); p.115 (G6.x connector).
Source scope reviewed 22 November 2026. Use the document revision and complete fitted labels together; retain any mismatch for investigation instead of choosing a pinout or replacement by appearance.
FAQ and service enquiry
Can this feedback be evaluated without an exact Mitchell motor entry?
Yes, once the fitted device, supply and connection are positively identified within the documented feedback scope. Evaluate serial position and analogue signals and preserve valid incoming alignment/memory. Motor-run approval remains a separate setup decision.
Can I replace this option with the paired singleturn/multiturn version?
G6.1S identifies SRS50 singleturn; G6.1M identifies SRM50 multiturn. The separate G6.2 family uses SKS36/SKM36 with 128 analogue periods, while G7 options are HIPERFACE DSL. A generic “HIPERFACE” description is not enough to substitute those branches. LST and LSN are distinct motor families even where encoder options have the same names. Verify drive support, mounting, wiring, exact suffix and motor data before considering substitution.
What information should accompany a service enquiry?
Send the complete motor and feedback labels, drive model, connector photos, alarm text, fault timing and service history. Include the cable labels and any saved incoming alignment/data record. SpareFaber can then scope a UAE site investigation or send-in evaluation.
Request a UAE site visit or send-in evaluation. Scope, parts and turnaround are confirmed after reviewing the fitted configuration and fault.
Enquire about this encoder or resolver
Tell us what needs checking. We’ll review the details and confirm the scope and quotation before booking chargeable work.