What specialist testing can show
TI-5000JX bench. On the documented connection, check movement, index where fitted and commutation separately.
TI-3000JX motor run. Confirm the full motor order, power lead, phase reference and supported TI-3000JX setup.
Starting lead. TI-5682 on the documented 17-contact M23.
Kollmorgen GOLDLINE XT Incremental ABZ/UVW Servo Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| GOLDLINE XT · ABZ/UVW | Match the exact fitted motor and TI-5682 connection. |
| XT 50-frame example | Use the manufacturer publication for that frame’s envelope and encoder specification. |
| GOLDLINE resolver | Separate connection and test method. Confirm the fitted feedback option by order. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Incremental A/B/Z plus UVW commutation on the documented test branch. |
| Resolution example | 8,192 pulses per revolution on the cited XT 50-frame publication. Confirm scaling and actual encoder. |
| Starting fixture | TI-5682, 17-contact M23. |
Interface and measuring method
The receiver uses incremental channels for position and the separate commutation information for rotor sectors. The displayed count can depend on how the receiver decodes the edges.
Mounting and fit
Compare the actual XT frame dimensions and rear assembly to the technical drawing. Preserve the incoming index and commutation relationship before disturbing the encoder.
Wiring and connector scope
Use the matching Kollmorgen feedback table for the fitted plug. Verify supply, differential paths, UVW and shield before a powered check.
Internal motor and machine cables
Identify the motor connector and extension part numbers independently. Use the TI-5682 lead only on the indexed test connection.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Position changes but motor enable fails | Check the separate commutation channels and phase setup. |
| Count scale differs from machine travel | Confirm frame-specific pulse count and receiver decode. |
| Feedback fails on movement | Trace the isolated M23 harness and inspect retention. |
Angle of alignment and commissioning
Record encoder direction, mechanical reference and motor phase convention. Use the approved motor and drive procedure for a new reference or run.
Motor and drive applications
Kollmorgen GOLDLINE XT on the 17-contact M23 encoder branch
Use the XT frame and connector to distinguish the encoder branch from the GOLDLINE resolver branch.
Drawings, pin maps and manuals
- Mitchell Test Cable Index by Manufacturer Support. Kollmorgen Support Part Numbers, TI-5682
- Kollmorgen GOLDLINE XT 50-frame servo motor technical publication. Supplementary reference for the stated model or setup.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.