Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified technician can compare unloaded and connected waveform quality with compatible HTL instrumentation. Check both channel pairs and the reference. Treat the exact supply range and load as bench setup inputs.
Leine Linde XHI 861 729798-02 High-Current HTL Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 729798-02. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 729798-02 · 861900220 | 16 mm blind bore, insulated insert, 86-flange, 120° bracket. | 2048 ppr, 9–30 V DC, high-current HTL. |
| 729798-01 | The older sheet also shows code key 861900220. Compare the label suffix and mating drawing. | 1024 ppr on the older datasheet. Verify receiver scaling before changing units. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Mounting | Ø16 mm blind hollow shaft with insulating insert. M20 gland fits cable diameters of 8–11 mm. |
| Supply and driver | 9–30 V DC, high-current HTL, six incremental outputs. Maximum output load ±40 mA per manufacturer specification. |
| Resolution and output frequency | 2048 ppr, maximum output frequency 200 kHz. At this resolution 200 kHz is about 5860 rpm, before cable and receiver limits. |
| Mechanical rating | 6000 rpm maximum mechanical speed, subject to electrical frequency and machine limits. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Seat the insulated bore on the intended shaft. The bracket resists housing rotation while allowing for the machine's specified shaft motion. Check bore, available shaft engagement, bracket orientation and clearance against the exact drawing. Inspect the insert and clamp before using the manufacturer tightening procedure.
Interface and measuring method
The receiver counts the two incremental tracks, S00 and S90, to measure travel and direction. Sref marks the reference. Complementary outputs support the documented receiver arrangement. The high-current HTL driver needs a receiver designed for its signal level. Compare cable length and input frequency against the expected pulse rate.
Verified wiring
| Terminal | Function |
|---|---|
| 1 / 2 | Supply +E / 0 V |
| 3 / 4 | Sref / inverse Sref |
| 5 / 6 | Inverse S90 / S90 |
| 7 / 8 | Inverse S00 / S00 |
| Shield | Chassis per the encoder drawing |
Read the numbers on the terminal block and use the connection view in the exact drawing. Note the reversed ordering of the S90 terminals. Check shield bonds against the complete machine diagram.
Cables inside the motor and at the machine
This build terminates a field cable through the M20 gland. Match the diameter, pair layout, receiver and cable routing. Verify a disconnected loom against the terminal assignment and the receiver schematic before fitting a replacement.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Speed differs by a factor of two | Check the ID suffix and the receiver's ppr and edge-count settings. |
| Dropouts under load | Check bracket motion and clamp, then cable support, supply and both sides of each used signal pair. |
| Works at low speed only | Compare expected pulse frequency, cable length and receiver threshold or filtering. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The insulated hollow shaft and torque bracket fit industrial applications built around this exact mount. Establish the drive's input rating and count convention from its commissioning record.
Angle of alignment and commissioning
Set the bore and bracket to the manufacturer's fitting drawing. Record the count direction and reference behaviour before removal. If the machine relies on Sref, re-establish its datum through the machine procedure.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Exact 729798-02 manufacturer sheet. See the mechanical view, electrical specifications and numbered terminal table.
- Manufacturer 729798-01 sheet, archived copy. Compare the older 1024 ppr data and code key with the exact 729798-02 sheet.