Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified technician can check amplitude, phase and reference quality on an approved 1 Vpp receiver and fixture. Confirm compatibility with any Lenord+Bauer service instrument and the configured option. Exact Mitchell fixture and any motor-run support need separate confirmation.
Lenord+Bauer GEL 2444KZMT3K150 1 Vpp MiniCODER technical reference
Find your part number
Use the full label and suffix. The main reference is GEL 2444KZMT3K150. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| GEL 2444KZMT3K150 | Tangential right exit, module 0.3 target and 1.5 m flying lead per maker type key. | K analog 1 Vpp, Z tooth-on-tooth reference, M internal amplitude regulation. |
| GEL 2444 T signal option | Confirm the matching wheel and mounting details. | Separate TTL/RS-422 signal configuration in the manufacturer order table. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measurement | Bearingless magnetic sensor scans a matching precision gear wheel. |
| Signal pattern K | Differential 1 Vpp sin/cos per GEL 2444 type code. |
| Reference and outlet | Z tooth-on-tooth reference, M non-configurable internal amplitude regulation, T tangential outlet right. |
| Wheel module | 3 denotes module 0.3. Published assembly gap for that module is 0.15 mm ±0.02 mm in D-02T-2444. |
| Cable | K flying lead and 150 = 1.5 m. Match the actual lead and documented terminations. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Match the sensor to the wheel module, reference tooth, width and installed tooth count. Use the manufacturer's gauge for the applicable air gap. Check wheel runout and spindle movement across a full revolution with the machine isolated. A uniform gap at one point alone gives limited information about high-speed feedback quality.
Interface and measuring method
The rotating target changes the magnetic field at the sensor. The receiver interpolates the 1 Vpp sine and cosine signals, while the marked tooth supplies the separate reference. Determine counts per revolution from the installed wheel and receiver settings. The sensor order by itself does not identify the wheel tooth count.
Verified wiring
Use the D-02T-2444 connection table for signal K and the flying-lead option. Identify supply and return, both differential track pairs, the reference pair and shield from the exact table and spindle drawing. Wire colors and connector contacts vary with the connection option.
Cables inside the motor and at the machine
The reference order uses a 1.5 m flying lead. Obtain the spindle maker's bulkhead or drive lead drawing to map the termination. Compare cable exit, shield and any temperature wiring against the assembly before substituting a connector-equipped GEL 2444.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Signal weakens once per turn | Measure target runout and gap, then compare the two track amplitudes under the specified receiver load. |
| Stable A/B and missing spindle reference | Verify the reference-tooth arrangement and dedicated reference conductors. |
| Good signals and wrong position scaling | Check actual tooth count and interpolation or drive configuration. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Lenord+Bauer identifies GEL 2444 applications in spindle and other shaft measurement. Match the complete spindle order, wheel and receiver to the actual MiniCODER configuration.
For another MiniCODER, compare its documented wheel and fitting. GEL 2449 technical guide.
Angle of alignment and commissioning
Align the sensor to the target wheel and verify air gap throughout rotation under the OEM procedure. Confirm reference repeatability and signal quality before checking the machine's spindle orientation or datum. Use the actual spindle procedure for any required angular setting.
Drawings, pin maps and manuals
- Main technical PDF. Lenord+Bauer D-02T-2444. See the mounting, module/air gap, connection and type-code tables.
- Manufacturer reference. Match the exact order code or the identified motor option.
- Supplier full-order reference. Lists GEL 2444KZMT3K150. The manufacturer type key governs the option meanings.