Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use read diagnostics and PLC status to compare position validity and the configured process word. A qualified technician can verify supply at the approved breakout and test a disconnected network cable with an appropriate cable tester.
Leuze BPS 348i SM 100 PROFINET Barcode Positioning Sensor technical reference
Find your part number
Use the full label and suffix. The main reference is 50124983. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 50124983 · BPS 348i SM 100 | Optical head, 100 × 108.7 × 48.3 mm in the exact datasheet. | PROFINET RT. Identify the separate hood before choosing cables. |
| 50116471 · MS 348 | M12 connection hood with Mini-B USB service access. | A-coded supply and D-coded network connectors. Check the hood pin assignment. |
| 50116467 · MK 348 | Alternate hood for terminal connection. | Use the terminal assignment and grounding details for MK 348. |
| 50131256 · ME 348 103 | Connection unit with short M12 connector leads. | Match its wiring and cable routing to the manual. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measurement | Barcode positioning on the matching Leuze tape, published system range up to 10 km. Maximum traverse rate 10 m/s under specified conditions. |
| Output | PROFINET RT, integrated switch, up to 100 Mbit/s. Published measurement value update 2 ms. |
| Power | 18–30 V DC, up to 3.7 W according to the exact head datasheet. |
| Resolution | 0.001–10 mm configurable. Published reproducibility 0.05 mm at one standard deviation. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Install the head so its reading beam crosses the barcode tape within the reading-field plot for the SM 100. Check stand-off, angle and lateral tracking across the full travel. Inspect the window and tape for residue, damage, loose sections and discontinuities at joins.
Interface and measuring method
The optical reader finds absolute position from the tape and supplies process data over PROFINET. Check the device name and GSDML module mapping against the PLC project. Link LEDs can be healthy while the optical position is invalid. Use the process status and reader diagnostics to distinguish the two.
Verified wiring
| Connector or pin | Function |
|---|---|
| A-coded M12 PWR pins 1 and 3 | +18–30 V DC and 0 V |
| A-coded M12 pins 2 / 4 / 5 | Configurable SWIO1 / SWIO2 / functional earth |
| D-coded HOST/BUS IN pins 1 / 2 / 3 / 4 | Transmit + / receive + / transmit − / receive − |
Use the manual's separate BUS OUT drawing for that port and the complete hood diagram for shielding. Connect power and network to their designated ports. The MK 348 and ME 348 103 have their own connection drawings.
Cables inside the motor and at the machine
For an MS 348 hood, the exact sheet lists 50132079 as an A-coded power cord and 50135080 as a D-coded M12-to-RJ45 network cable. Check the length, mating ends and required cable environment. Use the drawing for the hood actually fitted.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Valid network with invalid position | Inspect window, tape, stand-off and line of sight. Review reader status while stationary. |
| PLC cannot establish cyclic I/O | Check link, device name, cable, GSDML and the PLC network project. |
| Failure repeats at one location | Inspect the matching tape section and reading angle before replacing the head. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on a travel axis with Leuze tape and the matching PROFINET controller. The hood can carry device-name/parameter data as described in the manual. Record configuration before swapping the head or the hood.
Angle of alignment and commissioning
Check stand-off and sightline against the optical field plot. Restore the tape and reader geometry and machine position offset using the equipment procedure. Verify known reference positions before returning to operation.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- BPS 348i operating instructions. Use the hood drawings and sections on electrical connection, installation and PROFINET diagnostics.
- Exact 50124983 datasheet. Contains head dimensions, operating data and compatible cable and hood references.