Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A suitable Ethernet bench can check connection, live read-only position and behavior across a revolution. Check the installed controller’s scaling and preset separately. Confirm any specialist fixture before assigning a named tester.
Lika AM58S-1314-MTP9-M12 Modbus TCP Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is AM58S-1314-MTP9-M12. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| AM58S-1314-MTP9-M12 | 3/8-inch solid shaft. Use the exact mechanical drawing and M12 port layout. | Multiturn absolute Modbus TCP. Confirm configured resolution and register format. |
| AM59H-1314-MT15-M12 | Separate hollow-shaft order in the Modbus TCP documentation. | Shared protocol manual. Verify shaft, mounting and hardware variant. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Resolution | Up to 13 bits (8,192 positions) within a turn and up to 14 bits of turns per exact item record. |
| Supply | 5–30 V DC on exact item cut sheet. |
| Output | Modbus TCP over Ethernet. |
| Mount and environment | 3/8-inch solid shaft, IP65 in the cut sheet. Use the dimensioned drawing. |
| Connection | Match the M12 supply and network views in the product drawings and manual. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Measure the shaft and match the coupling, pilot and axial clearance. Verify bracket rigidity and cable bend clearance. Protect the encoder from shaft loads outside the documented cut sheet.
Interface and measuring method
The controller reads position registers over Modbus TCP. A valid TCP link does not establish correct data interpretation. Compare the register address convention, access function, word order, scaling and preset to the manual and existing PLC program.
Verified wiring
Use the exact M12 connector diagram in the Lika documents. Identify the power and Ethernet ports separately before applying power or using a cordset. Keep the signal contact and mating views explicit in the machine record.
Cables inside the motor and at the machine
Use the specified power and industrial Ethernet cables for the installed M12 coding and port. Record the switch or PLC side, length and flex requirements. The machine cordset selection depends on both ends.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Network link exists but reads time out | Check the configured IP/subnet, connection target, function and documented register address. |
| Value changes but looks too large or reverses | Read raw words at known positions and compare word order, scaling and count direction. |
| Position offset after exchange | Compare saved preset and mechanical coupling reference with the controller configuration before writing parameters. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on a Modbus TCP machine position axis with compatible cabling and controller configuration. Record the exact device and firmware, PLC project and commissioned scale.
Angle of alignment and commissioning
Restore the mechanical datum, then verify direction, preset and turn behavior with the machine reference. Keep writes controlled and verify results over a known movement.
Drawings, pin maps and manuals
- Main technical PDF. Lika-authored Modbus TCP manual, AutomationDirect mirror. Match the exact AM58S order and manual revision.
- Manufacturer reference. Authorized distributor’s exact Lika item record with official cut sheet and manuals.
- Exact model cut sheet. Supply, mechanics and drawing links.
- Exact mounting drawing. Use the 3/8-inch shaft and port outline for fit.