Site visit or send-in evaluation
CNC scale diagnosis, Slider alignment, Installation. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible receiver or Magnescale setup can verify position and alarms at multiple travel points. Confirm supported adapters, resolution and CNC protocol before substituting test hardware.
Magnescale SR87 FANUC α Absolute Linear Scale technical reference
Find your part number
Use the full label and suffix. The main reference is SR87. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Scope is the SR87 family with the FANUC α (protocol A) option. Read the installed length and all suffix fields before ordering.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| SR87 · FANUC α option | Scale and slider ordered by effective length, cable direction, accuracy and reference information. | Protocol A in the SR87 catalogue specifies FANUC α, four-wire. |
| SR87 with another protocol code | Same family outline can include other control variants. | The catalogue lists Mitsubishi, Panasonic and Yaskawa options. Match the CNC interface separately. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measurement | Robust absolute linear feedback for machine tools. |
| FANUC option | Four-wire FANUC α, protocol A in the catalogue. |
| Family capability | Catalogue maximum resolution 0.01 µm and response speed 200 m/min. Installed resolution and operating limits depend on order and receiver. |
| Measuring length | Read the complete code and match the effective travel and total outline separately. |
| Cable and protection | CH33 family cable. IP65 in the cited catalogue under specified installation conditions. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the SR87 manual to plan datum, parallelism, slider alignment, support and clearance. Verify travel stops and cable exit before loosening either assembly. Check contamination, seals and any required air or lubrication arrangements from the exact manual.
Interface and measuring method
The scale sends an absolute position over the selected CNC protocol. The controller must match protocol, resolution and direction. A communication fault and a geometrically wrong position call for different checks.
Verified wiring
Use the SR87/CH33 manual sections for the exact cable suffix and the CNC connector drawing. The manual distinguishes connector and unterminated versions. Match the four-wire FANUC configuration before assigning contacts or making an adapter.
Cables inside the motor and at the machine
Magnescale lists CH33-xxCP, -xxCE, -xxNP and -xxNE in the SR87 instructions. Match scale outlet, termination, length and the CNC side. Capture the fitted cable suffix from the label.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No scale communication | Identify the actual protocol code, inspect CH33 terminations and use the OEM diagnostic method. |
| Alarm at a repeatable travel point | Inspect slider support, parallelism, scale damage, contamination and the flex loop at that position. |
| Stable feedback with wrong displayed travel | Compare CNC resolution, direction, reference position and offset to the commissioned record. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Scope this page to a FANUC α control with the corresponding SR87 configuration. The exact CNC option and full SR87 nameplate still need confirmation for each machine.
Angle of alignment and commissioning
Use the scale installation drawings and machine builder’s alignment procedure. Confirm direction, usable travel and the CNC reference against a known machine datum before production. There is no rotor commutation step for this scale.
Drawings, pin maps and manuals
- Main technical PDF. Official SR87 and CH33 installation instructions. Read mounting, cable and connector sections together with the selected control version.
- Manufacturer reference. Magnescale SR87 product data. Use the linked official catalogue and instructions for SR87 and CH33.
- Magnescale feedback scale catalogue. SR87 order fields and FANUC α protocol A reference.