Site visit or send-in evaluation
We can isolate a harness or drive fault in the HC-PQ system before any work on the motor's built-in feedback assembly. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents the TI-5637 cable relationship. Confirm the exact OBE102 test profile, module, supply and pinout with Mitchell before a TI-5000JX test. Obtain separate TI-3000JX motor run confirmation. Use the MR-C manufacturer's diagnostic procedure for the fitted drive.
Mitsubishi Electric OBE102 HC-PQ Servo Feedback Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is OBE102. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| OBE102 | Mitchell lists this device with HC-PQ and a 20-pin Honda test connection. Verify the label and motor build. | HC-PQ feedback with TI-5637 test lead. Obtain the exact electrical specification for the fitted unit. |
| OSA18 / 191247 | Separate Mitsubishi encoder used on applicable HF-SP builds. | Different encoder and connection. Identify by full motor order and PCB label. |
Production and end-of-life status
Mitsubishi identifies the MR-C/HC-PQ platform as legacy and documents migration options. Confirm OBE102's exact service availability separately.
Specifications
| Parameter | Value and scope |
|---|---|
| Exact device designation | OBE102 in Mitchell's HC-PQ cable listing |
| Test connection | TI-5637, 20-pin Honda |
| OEM motor platform | Mitsubishi Electric HC-PQ with MR-C, per the OEM legacy and renewal records |
| Examples from OEM combination table | HC-PQ033(B), HC-PQ053(B), HC-PQ13(B), HC-PQ23(B) and HC-PQ43(B). The encoder suffix still needs verification for the exact motor. |
| OBE102 detail still needed | Serial format, supply limits, PCB pin map, encoder geometry and internal loom |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
The service starting point is the fitted motor and its built-in feedback assembly. Photograph the rear cover, encoder support, shaft retention and wiring before disassembly. On an isolated motor, inspect for rubbing, trapped wires or movement of the retention. Obtain the exact OBE102 mechanical drawing and motor procedure before adjusting the assembly.
Interface and measuring method
The motor feedback reaches the MR-C system through its encoder lead. Confirm the serial signal format and differential connection on the motor drawing and drive interface before interpreting a data fault. Mitsubishi’s other servo families use different serial connections. A matching connector alone is insufficient to set the tester.
Verified wiring
The Mitchell catalogue identifies a 20-pin Honda plug for the HC-PQ / OBE102 test setup. Read the correct cavity numbers and view from the TI-5637 sheet and Mitsubishi motor drawing. Determine the operating supply, return, data and shield paths before any live checks. Keep the encoder PCB, motor harness and amplifier connector maps separate.
Cables inside the motor and at the machine
Use the exact HC-PQ order, including brake, shaft or gearbox suffixes, to identify the in-motor lead and cable to the amplifier. TI-5637 is the Mitchell fixture. Mitsubishi's MR-C renewal table separately identifies cable changes for motor and amplifier upgrades.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Encoder alarm after cable or amplifier replacement | Compare the original and replacement motor/drive combination, cable and connector key against the Mitsubishi table. |
| Intermittent alarm when cable moves | Inspect the Honda contacts, latch and strain relief. Check the isolated harness conductors and specified shield bonds. |
| Feedback is present but position changes after motor repair | Compare the rotor-to-encoder seating and original reference before commissioning. |
| No response at the controller | Verify the exact Mitsubishi serial option and the documented loaded supply at both ends before replacing the device. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Mitsubishi lists HC-PQ as an MR-C motor platform. Mitchell cross-references OBE102 for HC-PQ. The OEM list names the compatible motor and amplifier combinations. Use the fitted label to determine which OBE102 revision is present. For the separate HF-SP family, see the OSA18 guide.
Angle of alignment and commissioning
Preserve the encoder's installed orientation and the drive settings. The motor OEM must supply the procedure for rotor reference, initial offset and any stored settings. Match the motor and encoder before moving the feedback assembly or restoring data.
Drawings, pin maps and manuals
- Main technical PDF. Mitsubishi MR-C renewal table. Lists the supported motor and amplifier combinations and migration scope. Obtain a separate OBE102 encoder drawing for fit and pinout.
- Manufacturer reference. Mitsubishi's MR-C legacy product record names the HC-PQ and HC-KQ motor families.
- Mitchell manufacturer cable index. HC-PQ and OBE102 with the TI-5637 fixture.
- Mitchell Mitsubishi serial connection note. Connection families differ. Use the exact OBE102 drawing for service.