What specialist testing can show
TI-5000JX bench. Separate resolver excitation and returns at the documented fitted connector.
TI-3000JX motor run. Generic Resolver is a setup path after confirming actual poles, phase order, alignment and ratings.
Starting lead. Match the fitted FAS N resolver connector variant to a verified fixture.
MOOG Fastact FAS N Servo Motor Resolver Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| FAS N standard | MOOG specifies a resolver on this motor branch. The standard catalogue table lists a six-pole resolver. |
| FAS N0/N1/N7 and N2/N3 option | The MOOG resolver table also lists optional two-pole configurations for these frame groups. Confirm the complete order. |
| FAE N | MOOG identifies this branch with incremental encoder feedback and its own drive and connection scope. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Passive resolver. MOOG distinguishes standard six-pole and optional two-pole resolver configurations. |
| Motor versions | 230 V AC and 400/460 V AC family versions in the MOOG catalogue. Use the nameplate for the specific motor. |
| Connection choices | The MOOG and Mitchell tables identify separate screw, bayonet and IP67 arrangements. |
| Electrical limits | Use the resolver table row for the fitted option when specifying excitation, frequency and transformation ratio. |
Interface and measuring method
The drive excites the resolver and derives rotor angle from two modulated returns. Resolver pole count affects how often the electrical angle repeats over one mechanical turn. Match the actual option when interpreting a trace.
Mounting and fit
Use the MOOG frame outline for the flange and shaft envelope. Record the rotor/stator reference and fit of the rear assembly during service. Choose the resolver outline and connector arrangement from the complete order.
Wiring and connector scope
Match the signal connector identified in the MOOG FAS N table. Keep resolver excitation, sine and cosine pairs and thermal circuits separate. Check both connector views and the exact winding data before using the fixture.
Internal motor and machine cables
Identify the motor-side connector variant and drive receiver before ordering the machine cable. Record shield termination and the pin-to-winding map for the fitted installation. Request the exact internal loom by motor order.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both outputs absent | Verify excitation and the shared connector or harness before evaluating the resolver. |
| Angle repeats at an unexpected rate | Confirm the two-pole or six-pole resolver option and the drive setting. |
| One return changes with cable movement | Inspect the affected return circuit, plug latch and strain relief on the isolated harness. |
Angle of alignment and commissioning
Preserve the incoming resolver position and pole convention. Use the OEM procedure for the actual winding and resolver configuration when confirming alignment. Check the angle pattern against a complete mechanical turn under the approved method.
Motor and drive applications
MOOG Fastact FAS N
Identify which of the FAS N resolver connectors is fitted and choose its wiring drawing.
Related SpareFaber guides
Drawings, pin maps and manuals
- MOOG Motors. FAS N / FAE N, FAS N resolver and listed connection options
- Generic Resolvers. Supplementary reference for the stated model or setup.
- MOOG Fastact N servo motor catalogue. Read the FAS N resolver table, ordering information and frame-specific signal connector diagrams.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.