Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use the applicable Netzer jig and receiver or converter after confirming the installed interface. Check configuration, data validity and repeatability before changing zero. Verify a suitable Mitchell adapter and exact profile separately if proposed.
Netzer DS-25-16-DF-SB Electric-Field Absolute Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is DS-25-16-DF-SB. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| DS-25-16-DF-SB | Legacy Netzer drawing identifies this assembly and a 4.5 mm ID. | Confirm the installed electrical option and cable before applying the family pinout. |
| Current DS-25 family | Check the specified rotor option, outer diameter and mounting against the exact drawing. | The current guide documents SSI and BiSS options. Read the full configuration. |
| DKIT-DS-25-IF-S0 | Manufacturer development kit with mounted encoder and rotary jig. | BiSS kit accessory for evaluation. Verify the installed production encoder separately. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Mechanical identity | Use DS-25-16-DF-SB-ICD for the legacy assembly. Drawing specifies 4.5 mm ID. |
| Measurement | Electric-field absolute angle measurement. Match the installed output option and data format. |
| Current family | Netzer's current DS-25 record and guide list their own cable, output and resolution keys. |
| Supply and limits | Read the actual label and electrical drawing before connecting supply, programming hardware or a receiver. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Compare the legacy drawing, shaft adapter and axial stack with the fitted assembly. The rotor and stator need stable concentricity and clearance throughout rotation. Inspect the clamps, seating surfaces and strain relief. Use the exact assembly drawing rather than borrowing dimensions from a current model with a similar name.
Interface and measuring method
Netzer describes an electric-field sensor that resolves absolute angle without contacting the rotating part. Depending on the installed build, the receiver may use a digital or analogue interface described in the applicable revision. An encoder that fits mechanically still needs the correct receiver type, framing and zero setup.
Verified wiring
The legacy DS-25-16-DF-SB reference verifies the mechanical drawing. Obtain the matching electrical drawing or manufacturer confirmation from the full label and lead before mapping power or signals. Current DS-25 SSI and BiSS family diagrams are useful for identification once the exact output is confirmed.
Trace a disconnected harness end to end and identify any intentional shield or case bonds from the machine schematic. Use the approved receiver and load for powered diagnostics.
Cables inside the motor and at the machine
Identify the fitted lead, housing, far-end connector and receiver. The current Netzer guide lists development kits and converter options. Confirm their applicability to the actual legacy output and connector before using them in service. Request an exact replacement assembly from the motor or machine manufacturer.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No position at the controller | Check exact output option, mating loom and supply before interpreting the controller alarm. |
| Angle changes near a repeated position | Check runout, clamp movement, axial spacing and cable movement at that position. |
| Count is stable but origin is wrong | Compare original zero and direction. Check the saved calibration or machine offset. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the exact DS-25 assembly only with the machine's documented interface and adapter fit. The current compact series covers multiple output configurations. The machine documentation governs suitability and commissioning.
Angle of alignment and commissioning
Set the geometry per the fitted drawing. Back up the installed configuration and zero with the supported Netzer tool or machine procedure. Keep the original configuration record and verify reported angle through known mechanical positions.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Current DS-25 family guide. Covers ordering and calibration for the documented configurations.
- Legacy DS-25 drawing. Find DS-25-16-DF-SB-ICD in the drawing section.