Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A qualified test on the correct supply and load can verify 1,024 A-channel periods per turn, A/B phase, Z and output levels. Follow the datasheet for circuit limits. Confirm exact Mitchell test profile and adapter if considering that equipment.
OMRON E6C3-CWZ5GH 1024 P/R Complementary Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is E6C3-CWZ5GH 1024P/R 1M. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| E6C3-CWZ5GH 1024P/R 1M | Ø50 mm body, 8 mm shaft, 1 m integral shielded lead. | 1,024 P/R, 12–24 V DC nominal, complementary A/B/Z outputs. |
| E6C3-CWZ5GH 1024P/R 2M | Same family fit with 2 m cable. | Same output and resolution. Verify the actual installed lead length. |
| E6C3-CWZ3XH family | Similar family body. Read the exact resolution and lead on the label. | RS-422A line-driver version. Separate signal and supply requirements. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Supply | Nominal 12–24 V DC. Datasheet limits 12 V −10% to 24 V +15%. Check ripple limit in the ratings table. |
| Signals | A/B quadrature and Z index, complementary output circuit. 1,024 pulses per revolution. |
| Frequency | 125 kHz maximum response frequency, 65 kHz when using phase Z reset, as specified in the data sheet. |
| Mounting / speed | Ø50 mm body, Ø8 mm shaft, 5,000 rpm mechanical maximum. Apply the lower electrical or mechanical limit for the application. |
| Lead | 1 m integral shielded cable. The 2M order code uses a 2 m lead. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the E6C3-C family drawing for the pilot, shaft projection, shaft flat and mounting hole positions. OMRON lists E69-C08B as an optional coupling. Check shaft alignment, loads and clearance before assembly. OMRON's phase Z figure shows its relation to the shaft flat for the specified mounting view.
Interface and measuring method
The optical encoder outputs A and B pulses with a relative phase shift, plus a Z index. The CWZ5GH has a complementary output circuit that actively drives one wire per channel. The CWZ3XH line-driver family uses a different electrical circuit and extra complementary signal wires. Set the receiver for the actual CWZ5GH levels and input mode.
Verified wiring
Use page 3, Complementary Output Model, for the CWZ5GH integral lead. These are encoder wire colours. Verify the assignment at any machine connector against the OEM schematic.
| Wire | Function |
|---|---|
| Brown | Supply +Vcc |
| Blue | 0 V common |
| Black | A |
| White | B |
| Orange | Z |
| Screen | Follow the machine drawing. OMRON states the cable screen is isolated from internals and case. |
Cables inside the motor and at the machine
The order suffix specifies the integral cable length. Use 1M or 2M according to the application. For an external extension, verify the wire map, receiver thresholds, shielding and permitted cable length before connecting. Obtain the machine connector part number from the equipment drawing.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| All signals missing | Check loaded voltage and the common reference. Inspect the coupling for slip or a stationary encoder shaft. |
| One phase missing or count becomes erratic at speed | Compare A and B with the correct input load. Check lead strain and interference, then compare pulse frequency with the receiving input limits. |
| Z unavailable when homing | Check the orange wire and actual Z pulses during a controlled turn. Confirm that the configured reset mode respects the specified frequency. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use with a suitable incremental counter, drive or PLC input on machinery. Confirm complementary output compatibility, pulse count mode and the shaft/coupling fit. Keep machine safety interlocks independent of this diagnostic procedure.
Angle of alignment and commissioning
Set the mechanical alignment, then confirm count direction and home position. A reference pulse aids repeatable homing after restart. The standalone encoder does not define a generic servo commutation setting.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Ratings and phase Z orientation. Compare the CWZ5GH column and shaft view.
- CWZ5GH output diagram. Use the complementary output model.
- Mating dimensions and coupling. Shows the main encoder and E69-C08B.