Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A DeviceNet scanner or approved interface can verify node startup and the count in a controlled fixture. Check the exact model configuration and network health before attributing a communication fault to the encoder. Mitchell support is unverified for this exact part.
Pepperl+Fuchs DVM58N DeviceNet Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is DVM58N-011AGR0BY-1213. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| DVM58N-011AGR0BY-1213 | 10 mm × 20 mm solid shaft and clamp flange. Removable radial terminal cover. | DeviceNet with binary output, 12-bit turns and 13-bit angle. Y marks customized parameter settings. |
| DVM58N-011AGR0BN-1213 | Related Ø10 × 20 mm clamping-flange DeviceNet build. | The family ordering table calls N the unexpanded option. The BY version specifies customized settings. Compare the delivered parameters. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Shaft and flange | Ø10 × 20 mm solid shaft, clamping flange. Drawing 308150, page 1. |
| Position capacity | 13 bits per turn and 12 bits for turn count, 25 bits total. Scaling may alter the engineering units. |
| Supply | 10–30 V DC. No-load maximum 230 mA at 10 V or 100 mA at 24 V. |
| Bus and enclosure | DeviceNet up to 500 kbit/s, galvanically isolated interface. IP65 with correctly assembled cover. |
| Published mechanical limits | Maximum 12,000 rpm. Shaft load limits 40 N axial and 110 N radial. Check combined load and application life separately. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the shaft, locating spigot and clamping flange dimensions on page 1. Couple to the machine with a correctly sized coupling. Verify alignment and avoid transferring machine thrust through the encoder. Preserve the original terminal cover settings and gasket condition before separating the cover.
Interface and measuring method
The optical absolute sensing system tracks angle and turns. A DeviceNet host requests or maps the position using the device's profile. Polled operation and position scaling are described in the exact datasheet. The receiver must interpret the encoder's configured direction, resolution and preset before converting the position to machine units.
Verified wiring
Use the labels in the removable housing cover, page 3. Compare with the wiring and shield drawing on page 5. Take an isolated photograph of the terminals and switch positions before removing a conductor.
| Mark | Function |
|---|---|
| + / − | Encoder supply / return |
| Ground symbol | Power supply ground connection shown in drawing |
| CG | CAN reference, on bus in and bus out |
| CL / CH | CAN low / CAN high, repeated for both bus connections |
| T | Switch for internal 121 Ω end termination |
Cables inside the motor and at the machine
Use the DeviceNet bus cable and gland specified by the machine designer. Confirm DeviceNet shield routing and whether the head is at the physical end of the trunk. The radial cover uses terminals and does not require a generic M23 loom. Document bus in and out before transferring them.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Both LEDs off | Check the power terminals and supply. Isolate the harness to check conductor continuity and unwanted bonds. |
| Supply present but no usable position | Confirm the configured unique node address, 125/250/500 kbit/s switch setting, trunk termination and scanner configuration. |
| Stable data but wrong machine value | Compare raw position with known motion. Inspect coupling slip, configured code sequence, scaling and preset. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use on a DeviceNet-controlled machine axis with a matching scanner or gateway. Confirm exact EDS and scanner I/O mapping with the installed PLC project. The datasheet documents the encoder and configuration attributes.
Angle of alignment and commissioning
Back up address, baud, count direction, resolution, total range and preset before replacing the Y-code encoder. At the OEM machine reference position, restore and verify its preset and count direction. The feedback encoder is a standalone measuring device. Establish servo commutation using the motor and drive procedure when the machine has a separate motor encoder.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- Connection and configuration, page 3. Terminal diagram, address, baud, termination and LEDs.
- Ordering code and position attributes, page 4. Decodes the shaft, output, resolution and Y option.
- DVM family ordering table for the N option. See page 7 for the unexpanded option and mounting codes.
- Related DVM58N-011AGR0BN-1213 listing. Compare the configuration before choosing this part.