Site visit or send-in evaluation
Tape and reader diagnosis, Installation, Commissioning support. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A bench can check ordinary read quality, power and network response with the correct tape and host. Safe function and stop behavior require validation on the configured machine.
Pepperl+Fuchs PXV100A-F200-B28-V1D safePXV PROFIsafe Read Head technical reference
Find your part number
Use the full label and suffix. The main reference is PXV100A-F200-B28-V1D. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| PXV100A-F200-B28-V1D | Fixed optical read head. Use the exact outline and compatible Data Matrix tape. | PROFINET and PROFIsafe. Check approved safety configuration and device revision. |
| PXV100A-F200-B28-V1D-6011 | Separately documented suffix with its own instructions. | Use the correct manual and approved configuration for the device label. |
| PXV100AQ-F200-B28-V1D | Separate AQ order in the safePXV manual. | Confirm its exact connection and application before any exchange. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring method | Incident-light optical reading of position from Data Matrix code tape. |
| Network | PROFINET standard communication and PROFIsafe safety channel. |
| Power connector | Separate 8-contact M12 Main plug. |
| Optical geometry | Use the exact datasheet working distance, reading window and mounting limits. |
| Machine variant | Keep the head, tape type, controller configuration and safety project together. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Check bracket stability, working distance and field of view from the Pepperl+Fuchs drawing. Inspect tape continuity, orientation, contrast and contamination along the travel. Protect the lens and observe the tape installation limits at joints.
Interface and measuring method
The head reads Data Matrix patterns and sends position to the PLC. A safety controller evaluates the PROFIsafe channel and data-valid indications. Standard network connection and valid safe position are separate diagnostic stages.
Verified wiring
On the exact model manual’s Main 8-contact M12 connector, use its mating view. Network connections use their own port drawings.
| Contact or group | Function |
|---|---|
| Main contact 2 | +UB. |
| Main contact 7 | GND. |
| Main contacts 1, 3, 4, 5, 6 and 8 | Not connected in the cited Main power figure. |
Cables inside the motor and at the machine
Use the manual’s V19 cable guidance for the Main connector and the specified industrial network cordsets for PROFINET. Record the two ends, key and actual PLC or switch port. Match the cable and tape orders to the installation.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Position invalid in one part of the track | Inspect tape condition, head spacing and angle through that segment. Compare with status at a clean segment. |
| No connection at the PLC | Verify supply and network link, device name and station setup. |
| Ordinary position valid but safe validity false | Review the exact PROFIsafe diagnostics, address and controlled safety project. Keep safety validation with the responsible engineer. |
Motor and drive applications
Use the model on equipment with the specified safePXV tape and supported PROFINET/PROFIsafe control. Record the head revision and tape type. Apply only the exact manual revision to installation and safety checks.
Angle of alignment and commissioning
Verify head-to-tape alignment and coverage along the usable travel. Document scaling, direction, offsets and safety validation using the installed project and Pepperl+Fuchs manual.
Drawings, pin maps and manuals
- Main technical PDF. English datasheet for PXV100A-F200-B28-V1D. See the dimensional and connection drawings.
- Manufacturer reference. Pepperl+Fuchs CAD catalogue entry for the exact read head.
- Pepperl+Fuchs safePXV operating manual. Exact V1D and AQ versions, Main power pins and network commissioning.