Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a suitable J1939 interface and machine diagnostics to check physical communication, source address, position and scaling. Confirm any exact Mitchell support before using a fixture. TI-3000JX is a motor-run platform and does not serve as the J1939 receiver for this application.
POSITAL UCD-C901B-1213-Y10S-PRR SAE J1939 Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is UCD-C901B-1213-Y10S-PRR. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| UCD-C901B-1213-Y10S-PRR · 1644723 | 58 mm synchro flange, Ø10 mm solid shaft, radial M23. | SAE J1939, 13-bit within turn and 12-bit turns. |
| IXARC UCD CANopen variants | Compare flange, shaft and connector against the exact item. | Different receiver protocol and configuration. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 13-bit single-turn and 12-bit multiturn. Magnetic sensing and self-powered turn count. |
| Supply | 9 to 30 V DC. The manufacturer lists up to 50 mA at 24 V DC. |
| Shaft | Ø10 mm × 20 mm solid shaft, 58 mm synchro flange in item 1644723 record. |
| Connector | Radial male M23, 12 contacts, CW/right layout. Confirm mating-view orientation. |
| Configuration | Resolution, preset, direction, node ID and baud rate are programmable per POSITAL. |
The table identifies the assembly each value applies to.
Mounting and fit
Check the flange pilot, shaft size and coupling engagement against the exact 2D drawing. Correct misalignment before tightening so the shaft and bearings do not carry avoidable radial or axial load. Inspect the radial connector for strain and leave room to secure the mating ring.
Interface and measuring method
The encoder sends absolute position in J1939 messages on a CAN bus. A controller can have an electrically active bus and still miss the right message because of a source address, baud rate or parameter mismatch. Check the physical bus and the message interpretation separately.
Verified wiring
Use the manufacturer’s connection-plan drawing for the male CW/right device connector. The mating female connector view is mirrored. Check the documented return and CAN reference individually.
| Contact or group | Function |
|---|---|
| 12 / 10 | Power supply / supply GND |
| 7 / 2 | CAN High / CAN Low |
| 3 | CAN GND |
Cables inside the motor and at the machine
POSITAL lists mating connector 10025698, M23 12-pin female CCW, in this product's accessories. Use the connection plan and the actual machine cable to verify the pin map, shield and bus topology. A stock M23 cable may need a different wiring arrangement.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No messages and bus errors are present | Check loaded supply, polarity, the CAN pair and machine-specified termination with the network in a safe test state. |
| Messages are present and position is ignored | Verify the source address, expected J1939 message and controller configuration. |
| Position tracks but has a fixed offset | Check the configured preset and direction, then compare the shaft reference and coupling. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this external rotary feedback device in a machine with a compatible J1939 controller. Verify item 1644723, shaft, flange and J1939 host configuration as a set.
For a different IXARC network family, compare the exact order code. POSITAL CANopen technical guide.
Angle of alignment and commissioning
Save the network settings and machine datum before removal. Set direction and preset by the approved machine commissioning procedure. Verify the actual position at known points and confirm that the controller still receives the expected messages.
Drawings, pin maps and manuals
- Manufacturer reference. POSITAL item 1644723. Exact datasheet, connection plan, drawing and accessory links.