Site visit or send-in evaluation
Share the complete code, HEIDENHAIN ID, motor and drive models, original phase reference, observed count and photos of the shaft, bore, cable and label. Keep the original hardware available when alignment must be established. Use the enquiry form to share the details.
What specialist testing can show
An appropriate differential receiver can compare A/B and index at the correct count scale and check U/V/W through a measured shaft turn. A qualified specialist can verify motor phase relationship on a suitable fixture. Mitchell documents certain older RENCO OEM models and differing wiring. Confirm exact R35i adapter, TI-5000JX and TI-3000JX compatibility before using a generic selection. RENCO differential signals and electronic alignment reference (PDF) · Mitchell notes on other RENCO assemblies
RENCO R35i 1188619-34 Commutation Encoder technical reference
Find your part number
Read 1188619-34 and R35i-8000/2-1/4-LD/LD-5V-1-R-C-U. RENCO's code identifies 8000 incremental periods and two commutation periods per turn, the nominal quarter-inch bore, two line-driver outputs groups, 5 V supply, reference type 1, radial connector, closed housing C and UNC mounting screw option U. Match every field when replacing a unit.
| ID | Incremental / commutation periods | Bore, reference and fit differences |
|---|---|---|
| 1188619-34 | 8000 / 2, LD/LD | ¼ in nominal (6.345 mm exact catalogue), A and B high gated 90° electrical index, closed housing, UNC screws. |
| 1188619-41 | 2500 / 2, LD/LD | 8 mm bore, A and B high gated 90° index, closed housing, metric screws. |
| 1188619-57 | 1000 / 3, LD/LD | ¼+ in (6.353 mm exact catalogue), high gated 90° index, closed housing, UNC screws. |
| 1188619-03 | 2000 / 2, LD/LD | ¼+ in (6.353 mm), A and B low gated 90° index, housing with central hole, metric screws. |
1188619-34 exact record · 1188619-41 · 1188619-57 · 1188619-03 · RENCO order code and reference gate (PDF)
Production and end-of-life status
HEIDENHAIN publishes an exact 1188619-34 catalogue record and RENCO family data. Confirm current production, repair and compatible replacements for the full ID. A catalogue record alone does not establish current supply. HEIDENHAIN exact ID record
Specifications
| Parameter | Value / scope |
|---|---|
| Measurement | Optical modular incremental rotary encoder without integral bearing. 8000 signal periods per turn. |
| Commutation | Two commutation periods per turn. Match the motor pole pairs and approved phase reference. |
| Output and supply | LD/LD differential line drivers for incremental and commutation. 5 V DC ±10%. Output frequency 1.83 MHz in the catalogue. |
| Mechanical | Radially fastened hollow through shaft, 6.345 mm as specified. Closed C housing, radial 15-contact connector, UNC screw build. |
| Environment | IP30 and −30 to +115 °C in the exact record. Fit and protection in the complete motor depend on the motor construction. |
Exact HEIDENHAIN electrical and mechanical data · RENCO ratings and mounting dimensions (PDF)
Mounting and fit
The encoder relies on the motor bearings and shaft for position. The stator mounts to the motor end housing, and the rotor fastens radially to the shaft. Match the bore tolerance and flange drawing. The C housing uses the closed flange with Ø32.5 mm screw circle in the RENCO ordering guide. Check shaft play and positioning, mounting tool, connector clearance and original assembly reference. Use the exact RENCO instructions and motor service dimensions for setting and fasteners. RENCO measuring fit, flange and mounting accessories (PDF) · Exact ID mounting and dimensions download titles
Interface and measuring method
A/B differential square waves measure relative position and direction. A gated reference pulse establishes an index. U/V/W supply repeating motor electrical sectors to the compatible receiver. With x4 edge counting, 8000 periods per revolution can yield 32,000 counts per turn. That count scale and the two commutation cycles per turn describe different tracks. Check their timing relationship to the actual motor and drive. RENCO RS-422, index and commutation timing (PDF)
Verified wiring
The exact catalogue specifies LD/LD, double-row 15-pin and drawing D730584. The following uses the R35i 15-pin LD/LD column in RENCO's brochure. Identify contact numbering by the drawing and verify any motor-side adapter separately.
| Contact | Function |
|---|---|
| 1 / 2 | A / inverse A |
| 3 / 4 | B / inverse B |
| 5 / 6 | Index / inverse index |
| 7 / 8 | U / inverse U |
| 9 / 10 | V / inverse V |
| 11 / 12 | W / inverse W |
| 13 / 14 | UP 5 V / 0 V |
| 15 | Vacant. Leave unassigned. |
The PP and R35iL wiring tables are different. Route the shield and complementary pairs using the matching cable drawing. RENCO R35i pin layout and interface (PDF) · ID 1188619-34 and D730584 designation
Cables inside the motor and at the machine
RENCO lists LD/LD 15-pin open-ended leads 1231752-N5 (0.5 m) and 1231752-01 (1 m) in the without-shield-connection table. It lists 1273058-01 (1 m) with shield connection. The factory cable data are separate from the motor bulkhead and drive pinout. Use the motor's own drawing to terminate the far end and verify shield and strain relief. RENCO output cable order numbers and wire colours (PDF)
Fault checks
Isolate motor, load and feedback supply before touching the encoder. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
- Inspect and capture. Record exact ID, installed index gate and drive fault. Check rotor clamp, bearing play, flange rigidity and the 15-pin connector for debris or backed-out contacts while safely isolated.
- Check the detached lead. With the harness isolated from the encoder and receiver at both ends, use resistance mode. First short the meter probes to establish lead resistance. Check each conductor end to end and flex the cable gently at the strain relief. Check between unrelated wires and from signal wires to shield or shell. Expect open only where the drawing calls for isolation. Compare any intentional sense links or shield bonds with the equipment drawing. Keep insulation testers away from connected electronics. Confirm all complementary pairs and the motor-end termination, not only supply.
- Check supply and signals. A qualified technician can install a documented breakout while off and compare pin 13 relative to 14 under load in an approved test. Use differential equipment to verify A/B, index and U/V/W against known shaft movement.
- Separate issues. Correct incremental count with the wrong index gate or phase can cause a commissioning fault. Missing signals only at the drive point to the harness/input. Repeatable count changes associated with end play or rotor slip warrant a mechanical inspection.
Motor and drive applications
This R35i build is a modular brushless motor feedback option where the drive uses differential quadrature and commutation channels. Verify motor pole count, phase convention, receiver bandwidth and the exact OEM installation. Mitchell's documented older RENCO connector variants use their own drawings. RENCO R35i motor and drive integration (PDF) · Mitchell older RENCO application examples
Angle of alignment and commissioning
Preserve the measured motor-specific relation between shaft reference, index, U/V/W and motor phases before disturbing the rotor. The RENCO brochure describes an electronic observation and mechanical setting method. Follow the actual motor OEM's reference and qualified service procedure. After fitting, verify the direction, count and phase relationship in a controlled test. A drive-stored offset, where applicable, is a separate commissioning value. RENCO commutation setting and verification (PDF)
Drawings, pin maps and manuals
- HEIDENHAIN 1188619-34 exact record. Full ordering code, shaft, pin layout designation and mounting document titles.
- RENCO R35i / R35iL brochure 1319497-21 (PDF). Exact interface class, selection guide, cable IDs and service geometry.
- HEIDENHAIN 1188619-41 exact comparison. 8 mm, 2500-line example.
- HEIDENHAIN 1188619-57 exact comparison. Quarter-inch plus and three commutation periods.
- HEIDENHAIN 1188619-03 exact comparison. Alternate 90° index gate and housing.