Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Evaluate setup indication across travel and compare differential outputs on a qualified scope with the documented load. A spare Ti alone cannot establish readhead condition without the compatible scale and geometry. Confirm Mitchell support with the complete readhead and interface codes before selecting a tester.
Renishaw TONiC T1030-15A Optical Linear Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is T1030-15A. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| T1030-15A | Optical readhead for the compatible RTLC20/RTLC20-S or RKLC20-S scale system. 1.5 m integral lead. | Interboard connection to compatible TONiC interface. Customer-selectable reference mark. |
| Ti0000A00A | Separate analogue interface between the readhead lead and controller. | 15-way D-type analogue 1 Vpp output. An accessory to the readhead. |
| Ti0004–Ti20KD | Digital Ti interface family. Read the exact code on the installed interface. | Digital differential output. Resolution and clocking depend on the interface code. Different D-type assignment from Ti0000. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Readhead body / lead | 35 × 13.5 × 10 mm TONiC body. T1030-15A has a 1.5 m interboard lead. |
| Scale / principle | Compatible TONiC 20 µm optical scale and reference selector system. |
| Analogue example | T1030-15A with Ti0000A00A. Nominal 1 Vpp differential sine/cosine. Supply 5 V ±10%, <100 mA for readhead with Ti0000. |
| Control resolution | Determined by the interpolation in the receiver or by the selected digital interface. Capture both codes on a service call. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Read the scale label before choosing the installation guide. On RTLC20-S, keep the readhead bracket flat, stiff and adjustable. Compare the drawing's optical centre line, ride height, yaw, pitch and roll against the actual carriage. Set clearance with the specified setup aid and confirm the setup LED over full travel. The scale, optic window and mounting faces need to be clean.
Interface and measuring method
The optical readhead produces periodic incremental signals as it passes the scale. With Ti0000A00A, the controller interpolates the two differential sinusoids and counts full scale periods. The separately selected reference mark lets the controller establish a machine origin after power-up. A digital Ti interface performs interpolation before sending pulses to the controller.
Verified wiring
This map applies at the Ti0000 analogue 15-way D-type output. Use the connector face diagram in the datasheet. The integral readhead cable's interboard plug and digital Ti variants have separate assignments.
| Function | Pin numbers |
|---|---|
| +5 V / 0 V | 4 and 5 / 12 and 13 |
| Cosine V1 + / − | 9 / 1 |
| Sine V2 + / − | 10 / 2 |
| Reference V0 + / − | 3 / 11 |
| Limit Vp / Vq | 7 / 8 |
| Setup Vx / CAL | 6 / 14 |
| Outer screen | D-type case |
Follow the data sheet's grounding drawing for the inner shield. Preserve the verified OEM screening arrangement at the machine.
Cables inside the motor and at the machine
The -15A assembly includes its readhead lead. Ti0000A00A is the confirmed analogue interface option. For the D-type-to-controller cable, verify the controller's sine/cosine input pins, screen routing and signal pair terminations in its manual. The finished machine loom is OEM-specific.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Setup LED degrades at a repeatable point | Check local dirt, scale damage, bracket flex and ride height through the same part of travel. |
| Good setup LED, lost counts | Compare signals at the Ti output and controller input. Confirm analogue versus digital receiver and cable pin assignment. |
| Counts move correctly, homing fails | Check the reference selector's location, the reference output and the controller's homing configuration. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Typical applications include precision linear stages and machine axes. Confirm whether the controller receives direct analogue signals or the digital Ti interface outputs before changing the scale, readhead or interface.
Angle of alignment and commissioning
Use the appropriate scale installation guide to set geometry and run its calibration sequence. On the machine, re-establish the reference and verify the count direction and origin. The reference selector and controller offset determine the homing result. Servo motor commutation uses separate feedback.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- T1x3x RTLC20-S installation guide. Use the mounting, calibration and output connections sections.
- T1x3x RKLC20-S installation guide. Use when the installed scale is RKLC20-S.
- Renishaw TONiC downloads. Family manuals and selection documents.