What specialist testing can show
TI-5000JX bench. Identify the M2/S2 code and test the EnDat path separately from the spindle drive and harness.
TI-3000JX motor run. Mitchell excludes these asynchronous spindle motors from TI-3000JX run testing.
Starting lead. TI-5093 at the motor or TI-5079 for the documented direct branch Module TI-5104 with TI-5093.
Bosch Rexroth MAD/MAF M2/S2 EnDat 2.1 Spindle Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| M2 | Multiturn absolute EnDat 2.1 in Rexroth’s MAD/MAF planning manual. |
| S2 | Singleturn absolute EnDat 2.1 in the same manual. Verify the complete spindle order. |
| M0 / S0 | Legacy Indramat digital feedback variants. Mitchell gives a different test setup. |
| C0 | Incremental branch, with separate wiring and signal test. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| M2 and S2 interface | EnDat 2.1 with 2,048 analog signal periods per revolution, nominal 1 Vpp, in the Rexroth option table. |
| Documented encoder supply | 3.6–14 V at the M2/S2 encoder in the Rexroth table. Follow the actual motor pin map and test fixture. |
| Test access | TI-5093 with TI-5104 at the documented motor connector, or TI-5079 for the stated direct branch. |
Interface and measuring method
The drive reads absolute position over EnDat and can use the 1 Vpp incremental tracks in the documented M2/S2 options. Serial response can be valid while the analog tracks or connector fail during motion.
Mounting and fit
Identify the spindle order, frame and cooling version. Compare the encoder mount, rear seat and coupling against the Rexroth drawing for that order. Secure and isolate the spindle before inspection.
Wiring and connector scope
Use the Rexroth M2/S2 feedback drawing and Mitchell’s EnDat branch diagram. Compare the serial clock/data and analog pairs independently. Verify the connector view and module arrangement before testing.
Internal motor and machine cables
TI-5093 and TI-5079 are different tester access paths. Identify the machine-side feedback cable and motor-side internal lead by full spindle order and feedback option.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| No data on a recently changed spindle | Decode M2/S2 versus the other feedback options before choosing the test profile. |
| Serial count reads but drive feedback alarms during speed changes | Check the analog tracks and harness under the approved test conditions. Inspect mechanical fixing. |
| Feedback checks pass but the spindle faults | Use the drive and spindle service information to check the remaining machine cable, drive inputs and spindle condition. |
Angle of alignment and commissioning
Mitchell says these asynchronous spindles do not require the synchronous-servo commutation alignment covered in its other guides. Verify mechanical fit, reference and drive configuration by the Rexroth procedure.
Motor and drive applications
Rexroth MAD air-cooled and MAF liquid-cooled spindle motors
Distinguish EnDat M2/S2 from I²C and C0 builds. Confirm the fitted feedback label and document spindle-specific service scope.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MAD & MAF Asynchronous Motors. Motor Encoder and Connection. EnDat 2.1 options M2/S2 and separate legacy I²C options.
- Rexroth MAD/MAF project planning manual R911295781. Rexroth-authored manual hosted by a distributor. See the motor encoder option table and motor feedback connection.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation