Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use an approved RS-422 counter, oscilloscope or RLS diagnostic method with the correct supply, load and scale. Check complementary signals, index periodicity and the LED along travel. Confirm the exact Mitchell adapter and profile if a specialist tester is proposed.
RLS LM13IC2D0CA10F00 Magnetic Incremental Readhead technical reference
Find your part number
Use the full label and suffix. The main reference is LM13IC2D0CA10F00. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| LM13IC2D0CA10F00 | RLS order example. F flying leads, 10 = 1 m with standard 00. Match the scale and fit drawing. | IC RS-422, 2D0 is 1 µm on the 2 mm scale, C periodic Z, A is 0.12 µs edge separation. |
| LM13 IC option 1D0 | Separate resolution option in the manufacturer order key. Match the complete order. | 2 µm on the 2 mm scale. Verify controller resolution and edge timing. |
| LM13IC10DBA10F00 | Published order example for an LM13 ring system. Confirm the matching ring. | Separate rotary configuration in the RLS ring document. Use the ring-specific count data. |
Production and end-of-life status
RLS lists the LM13 family and provides an order configurator. Confirm production and availability for the complete requested configuration.
Specifications
| Parameter | Value and scope |
|---|---|
| Code 2D0 | 2,000 interpolation increments per 2 mm magnetic pitch, 1 µm linear resolution. |
| Code C | Periodic reference pulse at the 2 mm pitch. Use a scale without a separate reference mark for this option. |
| Code A | 0.12 µs minimum edge separation (8 MHz option). Verify receiver capability even at low travel speed. |
| Supply | LM13IC data specify 4.7–7 V measured at the head and less than 35 mA unloaded. Account for cable drop and termination. |
| Connection | F flying lead, 1 m on this code. Differential A/B/Z and complementary signals. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Check the exact scale or ring, its mounting orientation and the head geometry. Use the LM13 and matching scale instructions for ride height, yaw, pitch and roll. Check the set-up LED along the full path. Account for the cover foil where specified. Local tape damage, magnetic contamination or a loose bracket can produce dropouts at the same location.
Interface and measuring method
The head reads alternating magnetic poles and interpolates the pattern into differential A and B edges. The controller counts those edges for movement and observes phase for direction. The C option provides a periodic Z pulse, so machine homing needs another documented way to identify a unique position. The receiver must handle the selected edge timing.
Verified wiring
Use LM13D01 page 8 option F for the factory flying leads. The D-sub columns apply only to the corresponding plug options.
| Function | Colour or pair |
|---|---|
| Vdd / GND | Brown / white |
| A+ / A− | Green / yellow |
| B+ / B− | Blue / red |
| Z+ / Z− | Pink / grey |
Follow the RLS drawing and receiver documentation for the inner and outer screens and line termination.
Cables inside the motor and at the machine
The reference order has a fixed 1 m lead. Confirm the shielded extension and receiver termination before adding length. The RLS 9-pin and 15-pin D-type order options have their own assignments. A replacement cable or adapter needs both end maps, especially if a cabinet already uses another D-sub standard.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Setup LED flags low signal | Check head orientation, power at the head, gap and scale condition. |
| Lost counts with acceptable setup | Verify the controller accepts the selected edge separation and inspect the differential pairs and termination. |
| Repeated reference pulses | The C option is periodic. Check controller homing and the scale order before replacing the head. |
| Fault occurs only along a section | Inspect local scale damage, cable carrier position and bracket movement. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this guide for the LM13IC order and the matching linear scale. RLS also documents axial and radial ring configurations. Confirm the actual scale type before interpreting counts per revolution or travel.
Angle of alignment and commissioning
Set the readhead and scale using the RLS geometry and LED procedure. After replacement, check resolution and count direction against measured travel and re-establish the machine reference. The C option supplies repeatable periodic marks and requires a machine datum to distinguish them.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- RLS LM13 option F lead map. Use the IC wiring and the F colour column.
- RLS LM13D01 order key. Includes LM13 IC 2D0 C A 10 F 00 and valid option combinations.
- RLS ring-system example. Separate rotary readhead and ring selection.