Site visit or send-in evaluation
Send the full motor nameplate and serial, /AK8Z and DI.E… codes if present, inverter type and firmware, cable labels and alarm history. Note whether the drive reads the motor nameplate at start-up and whether the fault follows cable motion. Use the enquiry form to share the details.
What specialist testing can show
Check the DDI device state, motor nameplate readout and position in the compatible SEW inverter or engineering software. Compare a known-good approved cable where the machine procedure permits. Do not connect a generic encoder supply or pulse tester to the DDI link. Exact Mitchell TI-5000JX and TI-3000JX support for AK8Z was not verified. SEW reserves work on the DDI communication unit for its service team. SEW communication-unit service instruction · SEW MOVILINK DDI motor instructions (PDF)
SEW-EURODRIVE AK8Z MOVILINK DDI Encoder technical reference
Find your part number
Look for /AK8Z on the complete motor type designation, then record the serial, size, DDI code and connector option. SEW treats /AK8Z as a motor feedback option. The orderable service assembly depends on the exact motor build.
| Motor option | Feedback | Identification detail |
|---|---|---|
| /AK8Z | MOVILINK DDI multiturn absolute | Add-on encoder. Match motor type, inverter and DDI option. |
| /EK8Z | MOVILINK DDI add-on encoder | DRN catalogue describes incremental and singleturn. Use the drive-specific option table. |
| /EK9Z | MOVILINK DDI singleturn absolute in the MOVIMOT advanced table | Different position range and motor applicability. |
| /AK8H | HIPERFACE option in the AC motor instructions | Different feedback interface. Match the full suffix. |
SEW DRN ordering options · SEW AC motor option and service instructions (PDF) · MOVIMOT advanced option table
Production and end-of-life status
SEW lists /AK8Z in the DRN gearmotor documentation and MOVIMOT advanced feedback data. Confirm exact motor option orderability and service replacement by serial number. Reviewed 7 November 2026. SEW DRN option catalogue · SEW MOVIMOT advanced encoder options
Specifications
| Parameter | Documented value or scope |
|---|---|
| Interface | MOVILINK DDI digital motor integration via coax on the documented SEW combination |
| DRN option catalogue | SEW describes /AK8Z as 18 bit incremental and 16 bit multiturn in the add-on encoder list. |
| MOVIMOT advanced receiver data | The applicable MOVIMOT advanced option table gives 16-bit singleturn and 16-bit multiturn for /AK8Z. |
| Supply and nameplate | MOVIMOT advanced table describes integrated 24 V DDI and ET2000 electronic nameplate. Use the matched SEW link. |
| Operating scope | MOVIMOT advanced option table lists IP66 and maximum 6000 min⁻¹. Use the actual motor and drive limits. |
Compare the published value for the exact motor/drive combination with what the inverter reports. The catalogue and application table describe different scopes, and the reported resolution should be checked on the actual system. DRN option list · MOVIMOT advanced application data
Mounting and fit
SEW groups AK8Z with its conical add-on encoders. The motor and encoder shafts couple internally, and the cover or adapter supports the assembly. The applicable motor drawing defines fit, insulation parts and fasteners. On the documented DR2C construction, disturbing the insulation coupling can change the synchronization between motor and encoder.
Check external cover seating, damage, cable strain and evidence of recent work. Follow SEW’s restriction on work at the DDI communication unit. Use the motor serial number to request the correct service assembly and alignment procedure. SEW conical encoder and DDI service instructions · DRN/DR2C motor instructions (PDF)
Interface and measuring method
MOVILINK DDI uses the documented coax link between motor and inverter to carry digital motor information and feedback. The inverter reads the electronic nameplate and receives position and applicable diagnostics. The DDI coax is a separate circuit from the motor and brake conductors even when they share one hybrid cable.
A loss of both nameplate and position suggests checking the common DDI path first. A valid nameplate with implausible position calls for checking the configured feedback, mechanical condition and OEM commissioning.
Verified wiring
| Connection | What to verify |
|---|---|
| DDI signal path | Match the keyed FAKRA coax connection to the applicable inverter and motor connection. Keep the center conductor and screen intact. |
| M23 or M40 hybrid connector | Power, brake and DDI functions depend on the motor option. Match the connector and the exact assembly drawing in the SEW addendum. |
| AK8Z internal connections | Identify the original harness and service assembly by motor serial. Internal DDI communication-unit work goes through SEW service. |
There is no general A/B or clock/data pinout for the coax path. Use the exact connector scheme and approved cable. For motor phases, brake and PE use the wiring diagram that belongs to the full motor type. SEW AC motor connection diagrams (PDF)
Cables inside the motor and at the machine
| Part number | Application from the cable table |
|---|---|
| 28123808 | Fixed installation, SD1/KD1 motor M23 to open inverter side with FAKRA DDI. 4 × 1.5 mm² + 4 × 1 mm² + coax. |
| 28123905 | Fixed installation, SD1/KD1 M23 to M23 hybrid. 4 × 1.5 mm² + 4 × 1 mm² + coax. |
| 28123832 | Fixed installation, SDB/KDB motor M40 to open inverter side with FAKRA DDI. 4 × 6 mm² + 4 × 1.5 mm² + coax. |
Match the exact motor connection, brake and inverter, current rating, length and movement class. These numbers are external assemblies. For the internal encoder-to-connector lead, request the serial-specific assembly from SEW. SEW cable selection tables (PDF) · SEW current cable selection reference
Fault checks
Before opening the hybrid connector. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized. Verify the motor, brake, DC bus and DDI energy sources separately under the SEW procedure.
- Inspect. Check the exact connector coding and latch, backed-out contacts, damaged coax, contamination, crush marks and excessive bend or flex near the entry.
- Check a fully disconnected cable. Only where the SEW procedure permits, a qualified technician can verify coax center-to-center and shield-to-shield continuity, and isolation between center and shield where the harness drawing calls for it. Keep all equipment and power conductors disconnected during these checks.
- Read the drive diagnostics. Check DDI connection state and electronic nameplate on the specified drive. If a cable swap is allowed, use a known-good approved assembly of the same connection type. Verify any control supply at the documented inverter test points rather than probing the live hybrid connector.
- Escalate internal or synchronization faults. If communication returns with the spare cable, inspect the original. If a known-good path still fails, or position faults began after motor work, take the fault log and serial to SEW service.
Motor and drive applications
SEW’s DRN option catalogue lists /AK8Z in the stated DRN size range. The MOVIMOT advanced documentation specifies compatible communication options and lists DFC and DSI in the cited encoder data. Match the motor and inverter documentation before applying the example. DRN gearmotor options · MOVIMOT advanced compatibility
Angle of alignment and commissioning
Record the motor type, DDI code, electronic nameplate and current inverter settings before replacement. The conical mounting and motor-to-encoder synchronization belong to the exact motor. SEW’s instructions direct work on the DDI communication unit to SEW service. Use the resulting approved commissioning process to verify direction, machine reference and any required motor angle before enabling torque.
Drawings, pin maps and manuals
- SEW AC motors operating instructions, 33090874 (PDF). Encoder options, construction and motor-specific service sections.
- SEW 31973426 AC motors with MOVILINK DDI (PDF). Connection diagrams and external cable part numbers.
- SEW conical encoder service instructions. Read the AK8Z communication-unit service restriction.
- SEW MOVIMOT advanced feedback data. Use the exact inverter and communication variant.