What specialist testing can show
TI-5000JX bench. Verify the exact AV1H connection before testing serial data and sine/cosine signals.
TI-3000JX motor run. Motor-specific run coverage remains open for the fitted SEW motor and drive.
Starting lead. Verify the AV1H connector and any direct HIPERFACE fixture. Confirm the fitted coupling.
SEW-EURODRIVE AV1H Coupling-Mounted HIPERFACE Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| AV1H | Listed with AV6H in the Mitchell-linked SEW coupling-mounted HIPERFACE row. Verify the exact fitted order. |
| AS1H / ES1H | Separate SEW option labels. The DFS/CFM instructions show a shared extension connection for the specified plug, with installation details for each. |
| AV1Y | SSI option in the SEW reference, with its own interface scope. Read the complete code. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | HIPERFACE multiturn with 1 V sine/cosine process signals in the cited SEW table. |
| Mounting | Add-on encoder with coupling in the documented AV1H/AV6H row. |
| Listed motor groups | SEW table identifies relevant DT/DV and CT/CV sizes. Verify the fitted motor code. |
| Cable choice | SEW documents separate fixed and cable-carrier extension types for the scoped DFS/CFM connection. |
Interface and measuring method
The drive reads absolute information via the parameter channel and movement from the sine/cosine pairs. A loose coupling can produce position error even when both electrical paths work.
Mounting and fit
Verify the coupling, shaft engagement, installed clearance and antirotation arrangement against the fitted motor outline. The SEW add-on and built-in variants have different fit requirements.
Wiring and connector scope
Use section 5.8.3 of the SEW DFS/CFM manual for the documented 12-contact extension cable. Read the drawing’s plug/socket views. The table below applies to that extension, and other motor connections require their own drawing.
| Contact or circuit | Documented scope |
|---|---|
| Contacts 3–6 | Cosine pair on 3/4 and sine pair on 5/6 in the stated extension drawing. |
| Contacts 7 and 8 | Data− and Data+ in the stated order. |
| Contacts 9 and 10 | Temperature circuits in the stated drawing. |
| Contacts 11 and 12 | GND and encoder supply. |
Internal motor and machine cables
For the DFS/CFM extension listed by SEW, 0199 5391 is the fixed-installation type and 0199 5405 is the cable-carrier type. Confirm the motor, plug and cable scope before using these numbers on another application.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Angle drifts after reversals | Check coupling movement, shaft engagement and any loose mounting before replacing the encoder. |
| Serial reads but analogue feedback is noisy | Inspect the sine/cosine pairs and the screen along the correct extension and drive connection. |
| Intermittent alarm at moving cable | Verify the specified carrier cable and connector engagement at both ends. |
Angle of alignment and commissioning
Preserve the coupling and original reference, then verify commutation, direction and any retained data with the exact motor/drive procedure.
Motor and drive applications
SEW DT/DV and CT/CV ranges listed for AV1H
Find the correct coupling and motor drawing for the AV1H add-on.
Related SpareFaber guides
Drawings, pin maps and manuals
- SEW Servo Motors. Attached Single-turn/multi-turn absolute encoder chart, AV1H/AV6H coupling row
- SICK Stegmann Hiperface Serial Encoders. Supplementary reference for the stated model or setup.
- SEW DFS/CFM operating instructions. Section 5.8.3 with the applicable AV1H extension drawing and fixed or cable-carrier numbers.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.