What specialist testing can show
TI-5000JX bench. TI-5000JX resolver checks with the fitted connector, approved excitation and matching SEW fixture.
TI-3000JX motor run. Confirm motor poles, commutation reference and compatible run setup for the exact order.
Starting lead. Use TI-5908 only on the documented SEW 12-contact M23 resolver connection. Verify this CMP plug.
SEW-EURODRIVE CMP63M/BK/KY/RH1M/SB1 Resolver Motor Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| CMP63M/BK/KY/RH1M/SB1 | The complete case in Mitchell’s SEW alignment note. Use all fields on the label when choosing the connection drawing. |
| RH1M | SEW resolver designation in the CMP operating instructions. |
| HIPERFACE CMP options | CMP can have an encoder option in the same motor family. Confirm the fitted feedback before choosing a connector or fixture. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback | Passive resolver with an excitation circuit and two quadrature return circuits. |
| Connection scope | Use the CMP drawing and the complete SB1 order when identifying the motor plug and mating cable. |
| Service reference | Mitchell links an exact CMP63M resolver example with its commutation convention. |
Interface and measuring method
The drive applies AC excitation and derives angle from the sine and cosine returns. A missing excitation can suppress both returns. A reversed or exchanged pair can still produce a smooth but incorrect angle.
Mounting and fit
Use the CMP63 motor outline for flange, shaft and connector envelope. Record the original resolver rotor and stator reference before disturbing the rear assembly. Obtain the fitted drawing for internal geometry.
Wiring and connector scope
Select the CMP manual’s RH1M connection drawing and compare it to the actual motor plug. Keep the excitation, sine, cosine, thermal and brake paths separate as indicated. Confirm connector view and pin numbering before testing.
Internal motor and machine cables
Use the motor order, connector and drive model to identify the SEW machine feedback cable. TI-5908 applies to the verified 12-contact M23 resolver arrangement. Check that arrangement on the fitted CMP before using it.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
A resolver is passive. Check isolated winding continuity against the matching drawing. Use the specified AC excitation on the approved test fixture for a signal check.
| Symptom | What to verify |
|---|---|
| Both return signals are absent | Check the excitation source and isolated harness before judging the resolver. |
| Only one return is weak | Compare the affected winding and cable pair separately against the motor drawing. |
| Angle moves smoothly and torque is irregular | Review the resolver direction, pair assignment and original alignment. |
Angle of alignment and commissioning
Preserve the incoming reference. Mitchell’s case gives a documented alignment convention for this example. Confirm the polarity, motor setup and measured angle on the actual motor before a qualified alignment or commissioning check.
Motor and drive applications
SEW CMP63M with RH1M
Verify the fitted CMP connector, excitation data, cable order and internal resolver assembly drawing.
Drawings, pin maps and manuals
- SEW Standard Alignment. CMP63M/BK/KY/RH1M/SB1 resolver example
- SEW CMP synchronous servomotor operating instructions. Type-code table, dimensional data and resolver connection drawings.
- Mitchell CMP63M RH1M resolver case. Exact documented motor example and alignment convention.
- Mitchell SEW Servo Motors. Scope of TI-5908 and connector variants.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation