What specialist testing can show
TI-5000JX bench. Use the matching singleturn profile and check analogue and serial paths with the correct connector.
TI-3000JX motor run. Confirm the fitted motor order and supported profile before assigning TI-3000JX scope.
Starting lead. TI-5650 on Mitchell’s documented AS1H/ES1H connection.
SEW-EURODRIVE ES1H Singleturn HIPERFACE Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| ES1H | SEW singleturn HIPERFACE option covered by the DFS/CFM connection tables. |
| AS1H | Multiturn variant covered in the AS1H guide. A shared plug drawing does not establish position or memory equivalence. |
| 12-contact ASTA 021 FR | Motor cable View X in SEW section 5.8.2. The CFM terminal box has a separate pin map. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position | Absolute within one turn on the ES1H option. |
| Interface | Classic HIPERFACE data pair and analogue sine/cosine pairs. |
| DFS/CFM manual | The 12-contact View X includes encoder supply and return, differential position channels and a thermal pair. |
| Connector style | SEW shows connector, extension and terminal-box arrangements separately in section 5.8. |
Interface and measuring method
The drive uses serial information for the within-turn position and analogue tracks for movement between serial reads. A valid identity with a position-quality alarm is a reason to check the sine/cosine path and cable separately.
Mounting and fit
Use the exact DFS or CFM rear assembly drawing. Preserve the motor reference, coupling orientation, seating and cable routing. Compare the shaft or coupling in the fitted order before ordering an encoder.
Wiring and connector scope
This pin table is for the 12-contact motor cable View X in SEW section 5.8.2. Use the OEM view to locate pin 1 and confirm keying. The terminal-box numbering differs.
| Contact or circuit | Documented scope |
|---|---|
| 3 / 4 and 5 / 6 | Cosine +/− and sine +/− respectively. |
| 7 / 8 | Data −/+ respectively. |
| 11 / 12 | Ground and encoder supply respectively. |
| 9 / 10 | Thermal pair TF/KTY +/− on the stated motor cable. |
Internal motor and machine cables
For the cited 12-contact DFS/CFM connection, SEW lists 1332 4535 for fixed installation and 1332 4551 for a cable carrier. Extensions 0199 5391 and 0199 5405 are the corresponding fixed and carrier references in section 5.8.3. Match the actual motor plug and drive end. Obtain the internal harness by motor order.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Drive reads the encoder ID but faults on movement | Check the sine/cosine pairs and shielding through the actual cable. |
| No identification at all | Check approved supply and data-pair continuity at the matched plug. |
| Fault began after fitting a terminal-box cable | Confirm the separate terminal numbering against the correct SEW drawing. |
Angle of alignment and commissioning
Record the incoming electrical reference and any motor-specific feedback settings before removing the encoder. Use the applicable DFS/CFM procedure to verify feedback direction and alignment on the installed assembly.
Motor and drive applications
SEW motor with fitted ES1H option
Identify the singleturn ES1H, fitted spread-shaft assembly and applicable motor-side cable.
Related SpareFaber guides
Drawings, pin maps and manuals
- SEW Servo Motors. AS1H/ES1H HIPERFACE test cable section
- SEW DFS/CFM operating instructions. Section 5.8, printed pages 48–51. Motor plug, extension and terminal-box circuits and cable orders.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.