Identify the fitted part
| Guide scope | SEW-EURODRIVE CMP40 AK0H — Motor application |
|---|---|
| Feedback identity | AK0H |
| MPN / full suffix | AK0H is the scoped designation. Retain all additional order characters and manufacturer IDs. |
| OEM service ID / motor order | Exact fitted-unit service number and motor order are not established; record them separately. |
| Interface | HIPERFACE multiturn |
| Starting connection | TI-5650 + TI-5104 only when the actual 12-pin M23 wiring matches |
| Configuration distinction | TCG228 is CMP63 resolver. AK0H differs from spread-shaft AS1H and conical AK1H with 1,024 periods. |
Specialist testing: connection before conclusion
| TI-5000JX bench scope | Conditional TI-5000JX bench scope: Identify AK0H on CMP40, conical-shaft mounting and 128-period tracks; save the original SEW motor data before replacement. Match the fitted drawing and enabled test profile. |
|---|---|
| Starting lead / fixture | TI-5650 + TI-5104 only when the actual 12-pin M23 wiring matches |
| Profile / module | Match exact profile, supply, connector and installed software; named cable evidence is not a complete setup. |
| TI-3000JX motor-run scope | Motor-run setup remains conditional: verify exact motor, poles, power/brake wiring, direction, alignment and installed TI-3000JX profile. |
The admission evidence is SEW Servo Motors — Linked synchronous-motor encoder table: AK0H, CMP40, conical shaft. Verify installed tester software, the actual sensor option and the fixture before connection. A bench result describes the tested configuration; it does not by itself clear the complete drive, brake, machine cable or loaded axis.
Production and replacement status
Current exact-order availability and an approved successor have not been confirmed. The linked technical references identify a configuration, not stock or universal replacement compatibility. Compare full labels, mechanics, interface, connector and motor data before ordering.
Specifications and interface
| CMP40 / AK0H | HIPERFACE multiturn with 128 sin/cos periods and 7–12 V supply in SEW’s encoder-system table; conical-shaft mounting. |
|---|---|
| Exact fitted order | Full suffix/ID, contact drawing, supply and receiver must match the actual assembly. Family specifications do not establish every unit. |
| Dimensions, fasteners and torque | Use the matching manufacturer drawing and revision. Unverified dimensions, air gap, torque and pin assignments remain open. |
Classic HIPERFACE combines analogue sine/cosine feedback with serial position, identity and device data. Evaluate those paths separately. Readable serial data does not prove healthy analogue tracks or correct motor memory. This scope does not extend to HIPERFACE DSL.
Mechanical fit and retention
Photograph the incoming shaft reference, locating seat, restraint, fasteners and cable exit before removal. After isolation, inspect accessible looseness, contamination, bearing roughness and rubbing. The actual drawing determines whether the unit has integral bearings, a clamped shaft or motor-supported sensing. Do not force a sensing assembly or substitute a torque from a similar model.
AK0H on CMP40 is the conical-shaft HIPERFACE multiturn option with 128 analogue periods. It is different from spread-shaft AS1H and the 1,024-period AK1H option. Preserve the original SEW electronic nameplate and verify the fitted connector before selecting TI-5650 with TI-5104.
Wiring and connector boundaries
Record the sensor plug, internal motor loom, motor bulkhead, external machine cable and drive/tester end as separate interfaces. Confirm gender, keying, contact numbering and mating-versus-termination view. Keep feedback, temperature, brake, motor power and shield contacts identified individually. A named test lead is not a pin map for an unverified adapter.
Starting connection for this guide: TI-5650 + TI-5104 only when the actual 12-pin M23 wiring matches. Use the source below for its named scope. Any unverified pin assignment remains open until the correct drawing is available.
Internal loom and machine cables
No internal OEM loom number or universal extension has been established for the exact fitted unit. Obtain its motor assembly drawing and both loom-end photographs. Select fixed or cable-carrier cable according to the actual installation, shielding and flex requirements. Mitchell lead numbers describe test fixtures and are not OEM replacement harness numbers.
Practical fault checks
Isolation and measurement conditions
Secure moving loads, isolate and lock out the relevant energy sources, follow the specified discharge time and have a qualified technician verify isolation before physical inspection or resistance checks. Disconnect both cable ends before continuity/short testing. Powered supply measurements, rotation, retention work and alignment require the approved fixture and procedure.
| Configuration to establish first | AK0H on CMP40 is the conical-shaft HIPERFACE multiturn option with 128 analogue periods. It is different from spread-shaft AS1H and the 1,024-period AK1H option. Preserve the original SEW electronic nameplate and verify the fitted connector before selecting TI-5650 with TI-5104. |
|---|---|
| Intermittent fault when the cable moves | With power isolated and both cable ends disconnected, inspect flex points, repairs, engagement and contamination. Check continuity and unwanted shorts using the correct contact drawing, allowing for intentional shield bonds. |
| No signal or communication | Confirm the fitted order and approved fixture before a qualified technician measures the specified supply using the OEM procedure. Compare source and load at the appropriate breakout; a connector shell does not specify voltage. |
| Position moves but the drive still rejects feedback | Record identity, position, alarms and direction. Check the supported signal paths, retention and motor pairing separately; do not reset or overwrite data as a first diagnostic step. |
| Serial reads but analogue quality is poor | Use the correct measurement fixture to assess both analogue channels and their relationship. Check supply, cable and mounting before condemning the sensor. |
Alignment, reference and memory
Record the incoming mechanical datum, direction and motor phase convention before disturbing feedback. Preserve recoverable identity, offsets and parameters where the exact interface and equipment support reading. There is no universal angle or memory image for this family. A specialist replacement requires the fitted motor procedure, supported fixture and verified hardware/data compatibility. Preserve the SEW electronic nameplate. The cited SEW description does not establish a universal individual offset-write instruction for this assembly.
Motor and drive applications
CMP40 AK0H. TCG228 is CMP63 resolver. AK0H differs from spread-shaft AS1H and conical AK1H with 1,024 periods.
A matching maker, connector shell or protocol name is not a complete compatibility chain. Keep motor order → feedback option → internal loom → bulkhead → machine cable → drive configuration recorded separately. No unverified alternate part is offered by this guide.
Drawings, manuals and evidence
- SEW Servo Motors — Linked synchronous-motor encoder table: AK0H, CMP40, conical shaft
- SEW Drive Engineering – Encoder Systems, 16742028 — Use the stated family, option and document revision only
Exact fitted order, internal loom, contact view, fixture, supply and motor-specific setup remain to verify. The linked family PDF is not an exact-unit identity or interchangeability approval.
Common questions
What should accompany a CMP40 AK0H enquiry?
Send clear photographs of the motor and feedback labels, every suffix/ID, both connector faces, drive model, exact alarm and the circumstances of the fault. Include recent wiring, bearing, encoder or parameter work.
Can the listed Mitchell lead be used as a replacement machine cable?
The lead is documented for the stated test connection. OEM internal looms and machine extensions require their own part numbers, pin maps and mechanical ratings.
Does a successful feedback bench test prove that the motor can be run?
Motor-run setup remains conditional: verify exact motor, poles, power/brake wiring, direction, alignment and installed TI-3000JX profile. A complete run assessment also checks motor power, brake, protection and mechanical conditions.
When does a site visit or send-in evaluation make sense?
A site visit can help when the fault depends on the drive, installation or moving cable. Send-in evaluation can isolate a removable feedback assembly or supported motor configuration. Agree scope, packing, availability and turnaround with SpareFaber after identification.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.