Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Use a supported HIPERFACE DSL master for identity, position, link errors and available condition data. The Mitchell TI-5743 and TI-5106 family references require exact 1067124 confirmation. Confirm the TI-3000JX motor-run setup independently with the complete motor order.
SICK EEM37-2KF0A015A 1067124 HIPERFACE DSL Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is EEM37-2KF0A015A. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| EEM37-2KF0A015A · 1067124 | Tapered shaft and 4-pin connector. Match motor mating drawing. | 15-bit per turn, 4096 absolute turns, HIPERFACE DSL. |
| EEM37-2KF0A017A · 1067125 | Related tapered-shaft item in family ordering table. | 17-bit variant. Check device identity and supported configuration. |
| EES37-2KF0A015A | Separate EES family. Compare drawing and item number. | Single-turn configuration rather than the EEM multiturn position format. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 15-bit per revolution and 4096 absolute turns for item 1067124. |
| Interface | HIPERFACE DSL over a combined supply and communications pair. |
| Supply | 7 to 12 V per item datasheet. Current up to 150 mA with the stated SICK integration circuit. |
| Mechanical | Tapered shaft. Verify the motor taper, stator connection and installed movement from SICK 8021265. |
| Connection | 4-pin DSL connector. Thermistor connection uses its separate documented path. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the SICK dimension sheet and 8021265 assembly drawing to check the taper and stator retention. Inspect the contact surfaces for contamination or damage, the fastener and the cable routing. Follow the mounting sequence and fastener specification for this exact safety-capable model and the motor.
Verify shaft seating and motor cover clearance with the system isolated. Correct installation, a suitable drive and validation of the complete application are required for a safety-related function.
Interface and measuring method
A compatible drive supplies DC and exchanges digital position data on the same pair. The physical cable, routing and termination affect whether packets arrive intact. A voltage reading verifies supply under the measured condition. Use the drive diagnostics or a suitable DSL master to check data quality, identity and errors.
Verified wiring
This is the encoder-side mapping in SICK product information. Match the drawing and JST GHR-04V-S mating housing. Separate temperature sensor pins use the temperature connection drawing.
| Contact or group | Function |
|---|---|
| 2 | +US / DSL+ |
| 3 | GND / DSL− |
| 1 and 4 | Unused on the DSL connector |
Cables inside the motor and at the machine
Use the SICK ordering table for the connector outlet and OEM motor drawing for the connection to the drive. Compare a hybrid motor cable’s DSL pair and shields with the approved motor/drive combination. TI-5743 is a direct DSL family lead in the Mitchell index. Confirm the exact item, mating connector and module before using it.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No feedback on power-up | Read the drive diagnostic and measure documented loaded supply using an approved setup. Inspect the DSL pair and latch. |
| Link errors when the inverter switches | Compare cable routing, shielding and termination with the OEM hybrid-cable drawing. Read DSL errors at controlled conditions. |
| Drive sees the device but refuses a replacement | Compare complete type, resolution, parameter memory and the machine’s safety validation requirements. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Match 1067124 to the motor OEM parts list and drive's HIPERFACE DSL feedback option. The OEM motor and hybrid harness order are application-specific.
Check a different DSL generation by item number. EDS35 technical guide.
Angle of alignment and commissioning
Before removal, capture the installed reference and the motor’s relevant data if the OEM procedure supports reading them. Follow the motor and drive commissioning process after fitting, then validate feedback and any safety function. Record which data were restored and the source for the approved procedure.
Drawings, pin maps and manuals
- Main technical PDF. Exact SICK 1067124 data sheet. Use the connection and mechanical drawings together with 8021265.
- Manufacturer reference. Match the exact order code or the identified motor option.
- SICK 8021265 operating instructions. Mounting, interface connection and commissioning for the safety-capable EES/EEM37 types.
- SICK 8017595 master integration manual. DSL physical link and receiver diagnostics.
- Mitchell cable index. TI-5743 family entry and connector scope.