Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Check HIPERFACE serial communication, position and status with a matched reader. Compare both sin/cos pairs under the documented supply and fixture conditions. Mitchell's HIPERFACE chapter covers general procedures. Confirm the exact SEK52 variant, profile and lead before using TI-5000JX or a complete-motor run setup.
SICK SEK52 HIPERFACE Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 1037368. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 1037368 · SEK52-HFA0-K02 | 12.7 mm tapered-shaft variant with the attachment pattern in the exact drawing. | Singleturn HIPERFACE, 16 sin/cos periods and axial 8-pin connector. |
| 1037369 · SEK52-H1A0-K02 | Hollow shaft with shoulder clamping. | Related singleturn SEK52. Use its own mounting drawing. |
| 1037370 · SEK52-HNA0-K02 | Hollow shaft. | Related singleturn SEK52. Match the shaft retention and loom. |
Production and end-of-life status
SICK support article KA-09965 records phase-out of SEK52/SEL52 on 20 December 2017. It names SEK37/SEL37 as an electrically compatible family with a different mounting interface. Confirm the motor maker's replacement plan. SICK lifecycle note.
Specifications
| Parameter | Value and scope |
|---|---|
| Measuring principle | Bearingless capacitive rotary feedback, singleturn. |
| Position data | 512 serial steps per revolution. 16 sine/cosine periods per turn on the process channels. |
| Supply | 7–12 V DC, 8 V DC recommended. Under 50 mA without load. |
| Speed | 12,000 rpm mechanical rating. SICK gives 6,000 rpm for reliable generation of the absolute position. |
| Fit and environment | 12.7 mm tapered shaft, axial 8-pin male connector, −40 to +115 °C operating range. |
| Memory | 1,792 bytes available. Confirm the OEM's data layout and approved access method. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Use the drawing for 1037368, including the taper, axial seating, shaft fastening and permitted attachment patterns. The drawing calls out an M4 × 20 DIN 912 fastener. The motor bearings and mating surfaces establish the encoder geometry. Check seating and movement before changing alignment, and use the OEM assembly instruction for screw torque.
Interface and measuring method
HIPERFACE carries the absolute starting position and parameter traffic on a bidirectional RS-485 pair. The drive separately tracks two analog sin/cos channels during motion. Compare each signal to its corresponding reference. Stable serial position with irregular sin/cos points to the analog path or mechanical fit before a serial fault.
Verified wiring
This map applies to the axial 8-pin encoder connector on 1037368. Read the contact numbers and orientation from the exact SICK connection figure. Wire colors below describe the cable connection, so match the installed OEM loom separately.
| Pin | Signal | Documented color |
|---|---|---|
| 1 | Us | Red |
| 2 | SIN | White |
| 3 | REFSIN | Brown |
| 4 | COS | Pink |
| 5 | REFCOS | Black |
| 6 | 0 V | Blue |
| 7 | Data + | Gray or yellow |
| 8 | Data − | Green or purple |
The encoder supply return is separate from the housing. Follow the motor and drive drawing for shield termination.
Cables inside the motor and at the machine
SICK lists DOL-0J08-G0M2XB6 (2031086), an 8-pin female JST to open leads, nominal 0.2 m and unshielded, and LTG-2708-MW (6028361), shielded bulk cable. These are separate components. Obtain the complete internal lead and motor bulkhead pinout from the motor maker before fabricating a loom.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Drive reports no serial feedback | Check the 7–12 V supply under the approved test conditions, connector seating and the Data pair end to end. |
| Serial position is stable but speed feedback is noisy | Compare SIN to REFSIN and COS to REFCOS, and check shaft seating, lead shielding and connector contamination. |
| Motor faults after a feedback swap | Verify singleturn vs multiturn configuration and match the motor reference or approved memory image. Check fit before applying motion. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
SICK documents SEK52 for servo motors and feeder axes. Verify the exact motor, connector and drive option. The replacement-family note is useful for electrical matching, while the taper and housing still require an application-specific mechanical review.
Angle of alignment and commissioning
First seat the taper and secure the stator using the motor and SICK drawings. Establish the motor commutation reference with the OEM commissioning procedure. Capture any documented motor-specific memory or drive offset before removal. Restore it only with the approved process for the same motor and validate feedback direction and alignment.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- SEK/SEL family catalogue. Variant drawings and the 2031086 encoder-end lead.
- Mitchell HIPERFACE chapter. Class-level testing and setup.