What Our Engineer can Test During the Visit with Encoder Testing Equipment,
Choose an on-site visit when the alarm occurs in the machine or the drive and feedback cable need to be checked together. If the motor or encoder is already out, include the complete SICK part number, motor order code and drive alarm when requesting a bench evaluation. Ask for packing instructions before sending an assembly.
What Our Engineer can Test During the Visit with Encoder Testing Equipment,
Mitchell’s TI-5000JX training manual covers SKM36 under SICK Stegmann HIPERFACE feedback. A matching fixture can check the device identity and status, the absolute position and turn count, and the analog sine/cosine track. Mitchell documents the TI-5104 adapter for compatible HIPERFACE setups. Select the bench harness and supply for the actual encoder and motor. Mitchell HIPERFACE test guide
A serial position that reads correctly confirms one feedback path. A specialist checks the two analog signals separately, especially if the drive alarms while moving. For motors that store a commutation offset in encoder memory, capture the original data using the applicable OEM method before replacement.
SICK SKM36 technical reference
Find the type and part number on your label
Record both the SICK type code and the seven-digit part number. The full suffix matters. These examples show how a similar name can identify a different shaft, connection or position range.
| SICK part no. and type | Shaft and mounting | Connection | Position |
|---|---|---|---|
| 1034094 · SKM36-HFA0-K02 | Tapered shaft, spring mounting plate | 8-pin radial integration connector | Multiturn |
| 1035601 · SKM36-HVA0-K02 | 6 mm solid shaft, standalone flange | 8-pin M12 radial connector | Multiturn |
| 1035602 · SKM36-HVV0-K02 | 6 mm solid shaft, standalone flange | 1.5 m integral cable | Multiturn |
| 1036558 · SKM36S-HFA0-K02 | Tapered shaft, spring mounting plate | 8-pin radial integration connector | Multiturn safety variant |
| 1034095 · SKS36-HFA0-K02 | Tapered shaft, spring mounting plate | 8-pin radial integration connector | Singleturn |
Production and end-of-life status
SICK publishes a data sheet for standard part 1034094. Confirm current orderability by full part number. SICK lists the special SKM36-HFA0-S02, part 1034601, as no longer sellable. Its service note describes special shielding and screws. Use the motor maker’s approved replacement, especially for a safety variant or an OEM-programmed unit. Checked 7 November 2026. SICK family overview (PDF) · SICK special variant service note
Specifications for SKM36-HFA0-K02
The values below apply to SICK part 1034094, the standard tapered-shaft multiturn version.
| Parameter | Manufacturer specification |
|---|---|
| Interface | HIPERFACE with analog sine/cosine and a serial parameter channel |
| Analog scale | 128 sine/cosine periods per mechanical turn |
| Absolute position range | 4,096 steps per turn across 4,096 turns, 16,777,216 steps total |
| System accuracy | ±120 arcseconds |
| Sine/cosine signal levels | 0.8–1.1 Vpp relative to their references. Reference offsets 2.2–2.8 V. |
| DC supply | 7–12 V at the device. SICK recommends 8 V. |
| Current draw | 60 mA without load |
| Operating speed | Up to 9,000 rpm for reliable absolute position formation |
| Connector | 8-pin radial male connector. See the device-side pin table. |
| Operating temperature | −20 to +110 °C |
| Enclosure rating | IP50 with the mating plug inserted and cover closed |
How the tapered version mounts
On 1034094, the 1:3 taper locates the encoder shaft concentrically in the motor shaft. The M4 threaded shaft connection retains it. The spring mounting plate attaches to the motor flange at two M3 fixing points and keeps the housing from turning with the shaft. SICK’s drawing shows the mating taper, hole pattern and allowed movement. The solid-shaft versions use their own flange and coupling arrangement.
With the drive isolated and the load and motor shaft secured, inspect the spring plate, seating and wire routing if the OEM allows access. Use the specified SICK tool and the manufacturer’s mounting procedure for removal, reseating and fasteners. Record the original fit and encoder settings before disturbing the assembly. Dimensional and mating drawings, pp. 4–5 (PDF) · SICK tapered-shaft mounting and removal, §3.4 (PDF)
Interface · How HIPERFACE supplies position
Measuring method: absolute multiturn, with incremental analog feedback for motion. The drive reads the encoder’s position and turn count over the bidirectional RS-485 HIPERFACE parameter channel. It can also read device identity, status and stored parameters. At startup the drive uses the absolute position as its reference, then tracks motion between serial reads from the analog sine and cosine signals.
Each analog channel has its own reference, SIN to REFSIN and COS to REFCOS. The drive interpolates their phase to estimate position within each of the 128 periods. The analog track and the serial channel can fail separately, so verify both when diagnosing a feedback alarm. SICK HIPERFACE interface description, §4.1 (PDF)
Verified device-side wiring for 1034094
Use SICK’s connector view in Figure 5 to identify pin numbers on the 8-pin integration connector. The standalone M12 connector uses the separate Table 2 assignment. Use the motor and drive makers’ drawings for the external harness.
| Pin | Signal | Function |
|---|---|---|
| 1 | US | DC supply |
| 2 | +SIN | Sine signal |
| 3 | REFSIN | Sine signal reference |
| 4 | +COS | Cosine signal |
| 5 | REFCOS | Cosine signal reference |
| 6 | GND | Supply return |
| 7 | Data+ | Positive serial data line |
| 8 | Data− | Negative serial data line |
SICK connector views and pin assignments, pp. 19–20 (PDF)
Cables inside the motor
Start with the encoder end, then match the motor-body connector by the full motor order code. The SKM36-HFA0-K02 (1034094) uses the small white 8-pin JST integration lead. M23 describes the connector family. The motor maker specifies the insert, keying, pin assignments, supply and any separate temperature wires.
| Applies to | Part number or connector | What to match |
|---|---|---|
| SICK SKS/SKM36 built-in JST versions | 2031086 · DOL-0J08-G0M2XB6 | 200 mm, 8-pin female JST to eight flying leads. SICK lists it as an unshielded lead for installation in the motor. Lead data sheet (PDF) |
| Rockwell MPF models in MP-IN004D | AEDC227NN00000012000 · Intercontec 17-pin M23 feedback connector | Motor-side connector reference. The drawings use different supply and return pins for the 5 V and 9 V motor groups. Match the original feedback option and supply. Rockwell connector data, pp. 15–16 (PDF) |
| SEW CM3C63–100 with AK0H, AK1H or EK1H | Intercontec 623 series · SEW insert · 12-pin M23 SpeedTec | Motor-side connector family. Order the harness or connector for the exact motor serial number and use the contact-end view in §5.6.4. SEW motor connector drawing (PDF) |
When making or repairing the loom. Use the SICK device pin table and the exact motor-end drawing together. Match the specified contacts, wire gauge, shielding, shell bond and strain relief. With the harness disconnected at both ends and separated from sensors and electronics, check each intended connection and check for shorts to adjacent conductors, shield and shell before reconnecting.
Bench cable. SICK 2071327 (DSL-2317-G01MJB6) goes from an 8-pin JST to a 17-pin M23 on the PGT-11-S programming setup. Use the motor maker’s harness or drawing for the installed loom. Bench cable data sheet (PDF) · SICK PGT-11-S cable assignments (PDF)
Checks before replacing the encoder
- Inspect the plug and mounting. Isolate the drive and all feedback supplies, follow the OEM discharge and verification procedure, and secure the motor and load. Inspect the connector for pushed-back pins, debris or a failed latch. Check the harness strain relief and accessible mounting hardware for movement.
- Check the isolated harness. Disconnect both ends and separate any sensor or inline electronics. Compare continuity end to end with the wiring diagram. Check for shorts between conductors that should be separate and between signal wires and the shield. A cable shield bonded to a connector shell can be intentional.
- Check supply under load. A qualified technician can use an OEM-approved breakout installed while isolated, then use the approved feedback-only test state with motor motion prevented. Check for 7–12 V DC between device pins 1 and 6 on 1034094. If the encoder-end voltage is low, compare it with the drive-end supply at the specified test point. Isolate again before removing the breakout.
- Separate the two feedback paths. If the drive cannot read the device, check supply and Data+/Data− continuity first. If identification works but the position or speed fails during motion, check the SIN/COS channels, their reference wires, shielding and coupling. A known-good compatible harness or a secured bench test helps distinguish a cable or drive fault from a fault inside the encoder.
Motor applications
Mitchell describes some Allen-Bradley MPL-A1xx motors with OEM feedback tested using the SKM36 selection. Match the motor order code and encoder label before selecting any supply, harness or replacement. Mitchell also documents Rexroth MSK applications with OEM SKS36 or SKM36 S01 feedback. For those builds, Mitchell reports that controller firmware MPx-V20 and later requires the S01 version. Check the controller and feedback option before selecting a replacement. Mitchell HIPERFACE guide · Rexroth MSK replacement guidance
Angle of alignment and encoder memory
For the Allen-Bradley MPL, MPF and 1326 HIPERFACE builds and Rexroth MSK HIPERFACE builds documented by Mitchell, the stored commutation offset belongs to the individual motor. The tester uses that offset to calculate electrical lockup angles for the motor. Match the motor and drive first, since other applications can use a motor-family reference or hold the offset in the drive.
- Read and save the original. On the appropriate secured bench fixture, select the actual encoder and motor memory profile. Record the motor model and serial, encoder type, and firmware where available. Confirm the read matches the motor label and that checksums pass. Save the original motor data file and record the derived +U/−V and +U/−W electrical angles when the software reports them.
- Restore the same motor’s data. Use the documented memory program function with a replacement approved for that motor and controller. Keep the original data file as a backup. Follow the OEM procedure for encoder calibration and safety variants. If the original cannot be read reliably, obtain the OEM data or use the motor maker’s commissioning procedure.
- Verify the assembled motor. Read back the programmed data, confirm its integrity and compare the recorded electrical targets with the assembled motor on the approved fixture. Verify the feedback direction, pole count and motor-specific alignment before returning the axis to service.
Mitchell Allen-Bradley memory and derived angles · Mitchell Rexroth memory and alignment · Mitchell memory read and program workflow
Drawings and manuals
- SICK 1034094 data sheet (PDF) for ratings, dimensions, signals and diagnostic status codes.
- SICK SKS/SKM36 operating instructions 8013452 (PDF) for installation, removal and wiring.
- SICK SKS/SKM36 family overview (PDF) to match the full variant.