What specialist testing can show
TI-5000JX bench. MSK memory workflow can read the motor-specific data and alignment with the documented setup.
TI-3000JX motor run. Exact motor-run setup open.
Starting lead. TI-5093 for the documented MSK motor connection Module TI-5104.
SICK SKS36-HFA0-S01 HIPERFACE Encoder for Rexroth MSK technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SKS36-HFA0-S01 | OEM singleturn HIPERFACE version named by Mitchell for Rexroth MSK. Record the complete encoder label and controller firmware. |
| SKS36-HFA0-K01 / K02 | Mitchell reports that these stock versions can be used on the documented MSK branch below MPx-V20. At MPx-V20 and above it specifies the OEM S01. Verify the exact controller and service part. |
| SKM36-HFA0-S01 | Multiturn OEM counterpart. Match the motor order and feedback architecture. |
| MSK060C-0300-NN-S1-UG0-NNNN | Mitchell’s SKS-equipped motor example. The complete encoder suffix still comes from the fitted label. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| MSK S1 feedback code | Rexroth’s planning manual lists optical, singleturn HIPERFACE with 128 signal periods for the S1 option. |
| Position and diagnostics | Check serial identity and absolute position separately from sine/cosine quality. |
| Connector path | TI-5093 and TI-5104 cover the documented MSK motor-side arrangement. Confirm the actual feedback socket. |
Interface and measuring method
The drive uses HIPERFACE serial data to read absolute position and memory. Sine and cosine signals update position during motion. The controller also checks the device it sees, so good analog channels alone do not establish replacement acceptance.
Mounting and fit
Identify the rear seat, shaft engagement, anti-rotation arrangement and connector exit from the fitted assembly. Use the MSK frame drawing for the motor envelope. Obtain the exact encoder assembly drawing for dimensions or fastener settings before a replacement.
Wiring and connector scope
Use the Rexroth motor connector diagram for the specified MSK option. At the isolated connector compare the shield, supply/return, analog pairs and serial pair with the drawing. Confirm plug view and orientation before tracing an internal harness.
Internal motor and machine cables
TI-5093 is the tester lead for the documented MSK bulkhead. Identify the OEM machine cable and any internal encoder loom from the full order and connector revision.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Rejected immediately after replacement | Compare the suffix, singleturn/multiturn mode, controller firmware and memory. Start with the S01 versus K01/K02 check. |
| Serial identity reads but position jitters | Inspect cable strain relief and check analog pair balance using the supported fixture. Also check the mechanical seat. |
| Bench result is good but the drive alarms | Check the complete machine cable, connector keying and drive alarm details. The bench fixture covers a shorter signal path. |
Angle of alignment and commissioning
Read the incoming MSK memory and retain the original data and alignment report before disassembly. Match the motor and encoder before transferring data. Have the qualified technician verify actual commutation after installation.
Motor and drive applications
Rexroth MSK
Compare the OEM S01 with stock K01/K02. Verify the installed controller and firmware before replacement.
Related SpareFaber guides
Drawings, pin maps and manuals
- Rexroth MSK support. Standard connection and Notes about Proprietary Replacement Encoders. S01 and controller firmware.
- Rexroth MSK project planning manual R911296289. Rexroth-authored manual hosted by a distributor. See Type Code and motor encoder connections.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.