Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible HIPERFACE bench can check analog quality, serial position and multiturn count. Mitchell lists TI-5069 plus TI-5104 for applicable SRS/SRM setups. The exact adapter termination for 1037097 and any motor-run profile need separate verification.
SICK SRM50-HWV0-K21 1037097 HIPERFACE Multiturn Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 1037097. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| SRM50-HWV0-K21 · 1037097 | Ø10 mm solid shaft. Radial 1.5 m eight-wire cable. | HIPERFACE multiturn, 1,024 periods and 4,096 distinguishable turns. |
| SRS50-HWV0-K21 | Related solid-shaft order. Check its own drawing. | SRS denotes singleturn. Match turn-count requirements. |
| SRS50-HZA0-S21 · 1037395 | Separate integrated feedback order, different mounting configuration. | See its own guide for taper, connector and singleturn information. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Analog tracks | 1,024 sin/cos periods per revolution. |
| Multiturn | 4,096 revolutions. Binary absolute data. |
| Supply | 7–12 V DC. SICK recommends 8 V DC. Typical 80 mA unloaded in the exact sheet. |
| Mechanical | Ø10 f6 shaft, Ø36 f8 pilot shown in exact drawing. Observe the mounting and mating-plug condition. |
| Connection | Integral 1.5 m radial eight-wire cable. SICK drawing shows a 40 mm minimum bend radius. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the exact face, pilot and Ø10 f6 solid-shaft drawing. Align the mating coupling without imposing axial or radial load. Inspect the clamp, torque restraint and cable bend clearance. Support the encoder while loosening the coupling and keep the hub from dragging on the shaft.
Interface and measuring method
HIPERFACE uses analog sine and cosine tracks for interpolation and a digital communication channel for absolute position and data. Check steady position over a turn and turn count separately from amplitude and phase. The guide for singleturn SRS50 does not establish multiturn behavior.
Verified wiring
Use the 1037097 data sheet’s Anschlussbelegung / PIN assignment on page 4 for the integral leads. Identify the supply and return, digital pair, and each analog signal with its own reference. Verify a motor plug from its mating drawing if the leads have been terminated in a machine connector.
Cables inside the motor and at the machine
The 1037097 data sheet describes a radial cable. An M23 cable in the accessories list is a separate assembly, and its connector assignment must be matched to the installed machine.
Mitchell documents TI-5069 and TI-5104 in the SRS/SRM family. Check the device-side termination and the adapter drawing before selecting it for this flying-lead unit.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Analog position noisy but serial reads | Compare both track pairs under the specified load. Look for radial play or cable strain. |
| Single-turn position good but revolutions wrong | Check controller multiturn setup and fitted label. Read the absolute turn count using a supported setup. |
| Intermittent on vibration | Check the solid-shaft coupling, cable entry and strain relief. Trace the isolated machine harness to distinguish a break from an encoder fault. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this exact order for service on a machine or motor documented to fit the solid-shaft SRM50. The Mitchell MOOG discussion establishes a family test lead. Verify the motor nameplate and connector before transferring that example.
Angle of alignment and commissioning
Record the axis direction, zero and any OEM commutation reference before disturbing the coupling. Refit mechanically and validate the installed absolute-position reference with the machine or motor procedure. Reuse of memory or offset data requires a compatible replacement and supported workflow.
Drawings, pin maps and manuals
- Main technical PDF. Exact 1037097 data sheet with dimensional drawing and flying-lead assignment.
- Manufacturer reference. Match the exact order code or the identified motor option.
- Mitchell MOOG motor feedback guide. HIPERFACE family lead and module scope.
- SICK SRS/SRM50 family ordering. Compare mounting options and singleturn versus multiturn.