What specialist testing can show
TI-5000JX bench. Check the singleturn serial profile and analogue channels on the fitted suffix.
TI-3000JX motor run. Verify the complete motor and supported setup before a run.
Starting lead. Verify the exact radial encoder connector and choose the compatible classic HIPERFACE fixture.
SICK Stegmann SEK34-HFB0K02 Singleturn HIPERFACE Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SEK34-HFB0K02 / 1053402 | Capacitive singleturn HIPERFACE, tapered shaft, radial eight-contact plug. |
| SEL34-HFB0K02 / 1053403 | Related multiturn model. Check the complete encoder and motor order before any substitution. |
| Kollmorgen AKM GP | Kollmorgen lists SEK34 on the documented AKM1 GP branch. Verify the fitted SICK and motor labels. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Analogue process data | 16 sine/cosine periods per revolution for 1053402. |
| Encoder supply | 7–12 V DC. The SICK data sheet recommends 8 V DC and lists up to 50 mA. |
| Mechanical | Tapered shaft and 33.8 mm nominal housing feature in the dimension drawing. Read the full tolerance and mating detail. |
| Environment | −40 to +115 °C and IP20 for the built-on, connected and closed encoder as stated by SICK. |
Interface and measuring method
The encoder uses capacitive measurement. The RS-485 parameter channel and analogue movement signals serve different functions. Check both when identity is readable but position quality degrades.
Mounting and fit
Use the 1053402 drawing for the tapered shaft, stator location and installed stack height. Check the locating and seating surfaces for contamination. Preserve the received reference and cable orientation before moving the encoder.
Wiring and connector scope
These assignments apply to the eight-contact plug-in face in the 1053402 data sheet. Use the illustrated keying. Confirm the motor bulkhead drawing separately.
| Contact or circuit | Documented scope |
|---|---|
| 1 / 6 | Encoder supply / ground. |
| 2 / 3 | Sine / reference sine. |
| 4 / 5 | Cosine / reference cosine. |
| 7 / 8 | RS-485 data +/−. |
Internal motor and machine cables
Identify the short radial connector harness from the fitted motor build. Match the other end at the motor bulkhead and trace the drive cable separately. SICK lists connector accessories in its data sheet. Confirm the compatible finished loom with the motor maker.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Reads model but faults when moving | Check both sine/cosine paths and references at the approved breakout. |
| Expected turns are missing | Read the exact 1053402 or 1053403 label and compare the drive configuration. |
| Offset changes after mounting | Verify taper seating and stator support against the fitted assembly. |
Angle of alignment and commissioning
Record the incoming motor reference and any OEM motor data stored in HIPERFACE. Fit the taper and stator to the exact drawing, then have a specialist verify the actual motor’s alignment before reuse.
Motor and drive applications
Kollmorgen AKM GC/GP and other documented fitted cases
Match the exact singleturn part, taper and pin view, and compare with the SEL34 multiturn version.
Drawings, pin maps and manuals
- Kollmorgen AKM support. Mitchell-linked AKM Feedback Description, GC and GP SEK34 rows
- SICK SEK34/SEL34 product information, SEK34 item 1053402. Manufacturer reference for the indicated motor or feedback option. Check the fitted revision.
- Mitchell-linked AKM Feedback Description. Reference for the fitted feedback or motor option.
- SICK SEK34-HFB0K02 item 1053402 data sheet. Exact dimensions, ratings and radial eight-contact plug-in face.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.