Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A compatible HIPERFACE receiver or approved bench fixture can read status, position and the process channels with the matching tape. Verify exact linear head support, adapter, supply and profile before using a Mitchell tester. A rotary servo fixture has different mounting and reference requirements.
SICK TTK70-HXA0-K02 1037434 Linear HIPERFACE Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TTK70-HXA0-K02. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TTK70-HXA0-K02 · 1037434 | Linear readhead with male 8-pin M12 and separate magnetic tape. | HIPERFACE analogue and RS-485 data paths. Standard version. |
| TTK70-HXJ0-K02 · 1063567 | 0.5 m factory eight-wire cable instead of the M12 device connector. | Same HIPERFACE family. Check the exact cable map. |
| TTK70S-HXA0-K02 · 1099700 | Eight-pin M12 head in the safety variant family. | Use the exact safety device documentation and acceptance process. |
| TTK70-AXA0-K02 · 1038033 | Separate 12-pin M12 configuration. | SSI interface. Match the controller and connector map. |
Production and end-of-life status
SICK publishes an exact 1037434 data sheet and family ordering table. Confirm current production and any announced replacement with SICK.
Specifications
| Parameter | Value and scope |
|---|---|
| Power | 7–12 V DC, 8 V recommended. Up to 65 mA without load. SICK separately lists approximately 100 mA during adjustment. |
| Connection | 8-pin M12 male for 1037434. Verify both connector ends from the drawings. |
| Repeatability and accuracy | Repeatability less than 5 µm, system accuracy ±10 µm at +20 °C in the exact sheet. |
| Readhead and tape | 70 mm head length per drawing. Tape ordered separately. SICK specifies tape length as measurement path plus 80 mm. |
| Protection | IP67 with mating plug inserted, −30 to +80 °C in operation. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
Mount the head and matching magnetic tape in the orientation shown on the SICK drawing. Account for the cover strip when measuring the gap. Check lateral offset and gap along the full usable travel with the prescribed gauge or installation method. Keep the tape flat and inspect for mechanical damage and ferrous debris. A fault at one physical point often tracks to the tape, head bracket or cable carrier.
Interface and measuring method
HIPERFACE uses a serial parameter channel and analogue process signals. The controller reads the head's absolute position and uses the analogue sine and cosine channels for fine movement between position reads. One path may work while the other fails. Inspect the serial status and both process tracks to separate wiring and mounting problems.
Verified wiring
This table follows the 1037434 data sheet pins. Use the connector drawing for the encoder mating view. The manufacturer lists alternative wire colours on cable builds. Identify the contacts rather than relying on colour alone.
| Contacts | Functions |
|---|---|
| 1 / 2 | REFSIN / +SIN |
| 3 / 4 | REFCOS / +COS |
| 5 / 6 | Data+ / Data−, RS-485 parameter channel |
| 7 / 8 | GND / US supply |
| Housing | Shield connection in the SICK assignment |
Cables inside the motor and at the machine
Use the compatible eight-contact M12 mating connector and a shielded four-pair loom to the approved receiver. SICK documents a separately ordered 0.5 m cabled readhead 1063567 and a 1 m cabled head 1068879. Those are readhead variants. Order any external extension by receiver end, length and motion rating. The TTK70 manual identifies the matching tape series and lengths.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No serial position | Verify the supply and RS-485 parameter pair. Read the SICK status code and compare with the cable test. |
| Serial works, process position is noisy | Check each signal against its own reference. Check gap across travel and the mounting bracket. |
| Status 21h at one location | The exact sheet identifies excessive tape distance. Inspect local gap, tape and head bracket. |
| New head reads but machine position differs | Check tape orientation, machine zero, direction and OEM configuration before motion. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use this guide for the standard 1037434 head and matching linear tape. The separately marked TTK70S has its own safety documentation. See the SRS50 guide for the separate rotary HIPERFACE application.
Angle of alignment and commissioning
Set head-to-tape geometry with the documented gauge and verify it through full travel. Establish the machine datum after mounting. Record any supported encoder memory and receiver parameters before replacement, then restore data only under the approved OEM procedure. The relevant mechanical adjustments are readhead geometry and datum.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- SICK TTK70 HIPERFACE installation instructions. Use the gap and cover-strip figures and the applicable electrical connection.
- SICK TTK70 family ordering table. Distinguishes M12, fixed cable, safety and SSI versions.