Site visit or send-in evaluation
Share the feedback label, complete motor or machine order, drive model and alarm. Include both connector faces and note whether the issue followed a cable change, replacement or mechanical work.
What specialist testing can show
TI-5000JX bench. Mitchell names AG100 on MAC and lists TI-5061 for the 12-pin M23 branch. Confirm the exact connector and SSI settings.
TI-3000JX motor run. Exact motor run setup open
Stegmann AG100 SSI Encoder for Indramat MAC technical reference
Find your part number
Use the full fitted label. A motor order identifies the assembly and should be recorded separately from an encoder part number.
| ID or order code | Identification and scope |
|---|---|
| AG100 | Stegmann SSI encoder named in Mitchell’s Indramat MAC application. |
| AG661 | A separately named SSI model used on Siemens 1FT5. Keep the full fitted ID and mechanical dimensions separate. |
Production and end-of-life status
Confirm current orderability and any successor for the exact ID with the manufacturer or motor OEM. The dated documentation identifies the configuration.
Specifications
| Parameter | Verified scope |
|---|---|
| Interface | Absolute SSI clock/data in Mitchell’s Stegmann training chapter. |
| Motor branch | Indramat MAC application. Check the motor and fitted feedback option. |
| Test lead | TI-5061 for the Mitchell catalogue’s 12-pin M23 SSI arrangement. |
Mounting and fit
Record the MAC order and feedback option, then read the Stegmann label before lifting the cover. Match the original shaft, coupling and attachment. Verify the fitted arrangement if an encoder has been replaced in the field.
Interface and measuring method
SSI sends an absolute position word on a clocked link. The named Stegmann SSI arrangement has no incremental channels. Some MAC motors use Hall signals for commutation separately from encoder position.
Wiring and connector scope
Use the exact 12-pin M23 drawing if fitted, then match clock, data, supply and shield by function. Compare the same connector face at both ends. Position SSI and motor commutation wiring are separate checks.
Cables inside the motor and at the machine
Mitchell lists TI-5061 for the Indramat MAC / Stegmann SSI arrangement. Confirm the exact motor bulkhead and its pin assignment before use. The OEM internal loom number remains open.
Fault checks
Before inspection. Follow the site’s isolation and lockout procedure. Secure any load against movement, allow the specified discharge time and have a qualified technician verify isolation. Check resistance on a disconnected harness at both ends. Use the documented shield and return connections.
| Observation | What to verify |
|---|---|
| SSI count remains constant during verified movement | Check clock and data at the correct receiver and verify the encoder coupling. |
| Position is plausible but the motor has a commutation fault | Check the separate commutation path in the fitted MAC configuration. |
| Replacement starts but reports an offset | Verify the SSI format, direction and machine reference before altering the encoder. |
Motor and drive applications
Indramat MAC. Full order open. Check the exact ID, drive and connector before applying an installation or test procedure.
Verify the SSI word format and motor-side connector. Locate the full AG100 label and MAC order.
Angle of alignment and commissioning
Identify whether the motor uses independent Hall commutation as in the Mitchell examples. Record the machine reference and verify the position after service. Follow the OEM alignment procedure for the installed MAC feedback configuration.
Drawings, pin maps and manuals
- Stegmann training chapter. Overview. AG100 on Indramat MAC, separate from AG661 on Siemens 1FT5.
- Mitchell test cable index. TI-5061 in the Indramat MAC and Stegmann sections.