What specialist testing can show
TI-5000JX bench. Mitchell documents TI-5000JX Indramat Stegmann servo and spindle profiles. Choose the correct ID, turn mode and TI-5021 connection.
TI-3000JX motor run. Confirm separate support for the exact MDD or 2AD motor and drive fixture.
Starting lead. TI-5021 on the documented Indramat serial connector.
Stegmann SCS70 Indramat MDD and 2AD Digital Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| SCS70 on Indramat MDD | Documented servo application. Read the full DSF marking and match the servo memory profile. |
| SCS70 on Indramat 2AD | Documented spindle application with less memory data. Use the spindle profile and actual ID. |
| SN-S and MN-S | Mitchell’s singleturn and multiturn Stegmann suffix clues. Verify the complete DSF number rather than selecting from SCS70 alone. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Feedback format | Indramat digital on the documented SCS70 variants. Match the motor and memory format. |
| Turn variants | Mitchell’s table lists separate singleturn and multiturn options for MDD and 2AD. |
| Test cable | TI-5021 on the supported Indramat serial connector branch. Verify the fitted plug. |
Interface and measuring method
Mitchell reports that these Stegmann devices need serial communication from the receiver to enable their incremental outputs. If data and incremental activity are both absent, start with the serial path and setup. A mismatch between servo and spindle memory maps can also cause test errors.
Mounting and fit
Match the exact MDD or 2AD assembly drawing and record the mounting seat, shaft connection and routing. Compare the fitted SCS70 marking and mechanical configuration before choosing a replacement.
Wiring and connector scope
Use the fitted Indramat connector drawing and TI-5021 view for the documented branch. Verify supply, return, data and incremental circuits separately. A service lead is not an internal harness drawing.
Internal motor and machine cables
Identify the internal lead from the exact motor order and the fitted SCS70 assembly. Use the appropriate MDD or 2AD machine cable and preserve the shield routing on any approved repair.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Many memory errors with a responding encoder | Confirm the MDD servo versus 2AD spindle profile and exact encoder ID before diagnosing memory damage. |
| No data and no incremental movement | Verify the Indramat serial path and receiver request. This Stegmann branch enables incremental outputs after serial communication. |
| Replacement reads but the drive refuses it | Compare full DSF label, turn mode, OEM data and recorded alignment. |
Angle of alignment and commissioning
Read and retain the original memory and observed alignment before disassembly. Confirm singleturn or multiturn, servo or spindle and exact part before writing data. Have a specialist verify the actual position and alignment after fitting.
Motor and drive applications
Indramat MDD servo and 2AD spindle with SCS70
Confirm the full DSF number, MDD or 2AD order, connector, fixture and memory format.
Related SpareFaber guides
Drawings, pin maps and manuals
- Indramat Digital Motors, Serial Encoders and Resolvers. Identification, SCS70 servo and spindle memory
- Mitchell Indramat supported types table. SCS70 servo and spindle rows, singleturn/multiturn options and TI-5021 note.
- Indramat MDD project planning manual. OEM-authored MDD motor scope and drawings. Obtain the separate 2AD manual for that branch.
- SICK legacy encoder support note. Manufacturer reference for SCS70 legacy product scope. Verify the exact OEM replacement with SICK and the motor maker.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation