Identify the fitted motor and feedback
| Configuration | EZ404U / S2 / no brake |
|---|---|
| Order-number scope | Convection-cooled U motor size, encoder code and no-brake configuration; separate EnDat 2.2 connection. Complete winding/KEM, shaft and connection order must be verified. |
| Feedback interface | EQI1131 EnDat 2.2 multiturn |
| Service scope | Motor feedback assessment; this listing is not an offer of a stocked replacement motor or encoder. |
Photograph the complete motor label, encoder label, connectors and mounting arrangement. Record the drive model and actual alarm text. The guide identifier describes the selected configuration; the received assembly must still match it, especially after an earlier repair.
Specialist testing: confirm the connection first
| TI-5000JX scope | Supported EnDat 2.2 identification, position and diagnostic evaluation at the separate feedback connection; no functional-safety certification. |
|---|---|
| Cable / fixture boundary | TI-5713 for the matching separate 12-contact M17 STÖBER EZ EnDat 2.2 feedback connector; verify actual wiring and fitted encoder. |
| TI-3000JX run scope | A motor-run assessment is conditional on the exact supported selection, successful prior feedback checks, winding data, power fixture and the tester current/voltage limits. Catalogue speed or size does not promise full-speed or full-load testing. |
Confirm the installed software selection, actual feedback option and fixture before applying power. Named family support establishes a route for evaluation, not automatic acceptance of every winding or repaired sensor combination. Record what the test actually covered and any excluded functions.
Production and replacement status
The linked manufacturer document identifies this catalogue configuration. Current production, availability and any approved successor require confirmation against the complete fitted order. A downloadable manual does not prove present stock. Compare voltage, winding, mounting, shaft, brake, feedback, connector and stored motor-data requirements before accepting a replacement.
Specifications and interface
| Motor / cooling | EZ404U / convection cooled |
|---|---|
| Encoder option | S2 — EQI1131 |
| Position resolution | 19 bits per turn; 4096 turns |
| Brake | None |
| Square flange / pilot | 98 mm / 95 mm |
| Shaft / projection | 19 mm diameter / 40 mm projection |
| Axial dimension q0 | 193.5 mm; no brake, inductive encoder; shaft projection separate |
| Feedback connection | Separate con.17 (M17) encoder plug; not One Cable Solution |
| OEM reference | 442437 EN, dimensions page 577, encoder options page 584, connection section pages 593–595 |
The selected C5/S2 options are inductive EnDat 2.2 encoders. S2 uses EQI1131 with multiturn position; its safety-related design does not turn an ordinary feedback check into a safety validation. The generic EZ family name also covers other encoder and connection systems. This guide admits only the stated separate EnDat 2.2 arrangement.
Mechanical fit and retention
The q0 dimension is for the no-brake motor. The optical-encoder x0 addition does not apply to these inductive C5/S2 options. Use the complete outline for flange pilot, shaft tolerances, plug rotation and bend space. Winding/KEM data and rated speed must come from the complete motor order.
Record the shaft datum, coupling position, pilot fit and feedback retention before disassembly. Inspect bearing play, shaft damage, contamination and moisture. Motor flange and shaft dimensions do not define the encoder coupling or its tightening torque. Use the actual assembly drawing for fasteners, retention and sealing, and record any previous modifications.
Wiring and connector boundaries
The EZ4–EZ8 separate encoder plug is con.17. The motor power connector is a different interface and its size varies by frame. Do not connect a One Cable Solution or EnDat 3 build using this M17 EnDat 2.2 guide. Verify the sensor-specific pin map in the OEM connection section.
Separate motor power, protective earth, low-voltage feedback and temperature circuits. Verify contact numbering, gender, keying and mating-face versus wire-side view. A connector that mates mechanically does not prove electrical compatibility. Check the permitted sensor supply or resolver excitation from its own documentation; the motor voltage rating is a different quantity.
This configuration has no holding brake. Arrange independent load restraint and verify the machine holding system before uncoupling or movement.
Internal loom and machine cables
Record the internal encoder-to-motor loom separately from the external machine cable and bench fixture. The internal loom part number is not established by the frame or interface alone. Obtain both connector faces, the assembly diagram and the correct contact view. Match cable length, shielding, temperature rating and fixed or flexing duty to the installation. A Mitchell test lead identifies a test connection; it is not an OEM replacement machine cable.
Fault checks and useful observations
| No feedback communication | Confirm the exact interface, fixture, supply and contact orientation. Check the selected connection boundary before concluding that the sensor is defective. |
|---|---|
| Position jumps or intermittent alarms | Record direction, movement range, cable position and temperature. Compare a stationary cable check with controlled movement where the supported setup permits it. |
| Fault after encoder or bearing work | Compare the incoming memory/reference record, fitted sensor identity, mechanical retention and phase relationship. A stable position display does not establish correct commutation. |
| Bench result differs from the machine | Check which loom, connector, drive interface and operating conditions the bench bypassed. Reproduce the actual symptom before recommending a component change. |
| Motor motion or holding issue | This configuration has no holding brake. Arrange independent load restraint and verify the machine holding system before uncoupling or movement. |
Keep each observation separate from the conclusion. State whether a fault is repeatable, which connection was tested and what changed after cleaning or adjustment. Avoid replacing an encoder solely because the drive reports a feedback alarm; a damaged cable, incorrect parameter or mechanical problem can produce a similar report.
Alignment, reference and stored data
Record encoder identity, position, alarms and available motor/drive parameter records before removal. Use the exact fitted alignment and commissioning procedure. No universal STÖBER memory-copy or automatic offset recovery is promised. Machine zero and any safety function need their own validation.
Preserve original records before any permitted change. An alignment operation concerns the motor/feedback relationship; machine home, travel limits and process offsets remain separate. Check the fitted procedure and document the measured result after reassembly.
Motor, drive and replacement matching
Match the complete chain: motor order, feedback option, internal loom, motor bulkhead, external cable and drive configuration. Similar frame size, speed or interface wording does not establish interchangeability. Confirm shaft and flange fit, brake requirements, thermal sensor, winding and stored-data requirements before approving a substitute.
A motor-run assessment is conditional on the exact supported selection, successful prior feedback checks, winding data, power fixture and the tester current/voltage limits. Catalogue speed or size does not promise full-speed or full-load testing.
Drawings, manuals and supporting evidence
- Mitchell STÖBER EZ / EnDat 2.2 / M17 cable entry
- STÖBER EZ motor documentation
- STÖBER 442437 EN catalogue, pages 577, 584 and 593–595
Source review: 21 November 2026. The linked OEM drawing identifies the stated catalogue/configuration scope. Confirm the document revision and complete fitted nameplate before extending wiring, replacement or motor-run claims. Legacy OEM manuals may be hosted by an independent document archive.
Common service questions
Is this a complete replacement order number?
Convection-cooled U motor size, encoder code and no-brake configuration; separate EnDat 2.2 connection. Complete winding/KEM, shaft and connection order must be verified.
Does a good position reading clear the whole axis?
No. Feedback, motor power, drive behaviour, machine cable, holding arrangements and loaded performance are separate evaluation boundaries.
Can the original encoder be replaced by another with the same interface?
Only after the mechanical fit, electrical connection, exact sensor/profile, stored data and alignment requirements have been checked for this motor.
What should accompany a service enquiry?
Send clear motor and feedback labels, connector photographs, drive model, alarm text and fault history. Describe recent repair work and whether the problem appears at startup, during motion or after warming up.
What the service record should contain
Record the received model, serial or service ID, fitted feedback, mechanical condition and original fault before work begins. Include the test profile, connection boundary, fixture and supply/excitation used. Preserve readable original memory or parameter reports where relevant. Record evidence before and after each adjustment so an intermittent condition is not reported as a confirmed cure without a repeatable check.
The assessment should distinguish a confirmed defect, a proposed repair and any unresolved condition. State tests that need the machine, a missing drawing or a different fixture. Replacement availability, service timing and the final repair scope are confirmed after inspection.
Request a scoped service evaluation
Use the existing encoder enquiry form with the labels, alarm and connection photographs. Specify whether you need UAE field diagnosis, installation/alignment assessment or send-in testing. Turnaround and repair scope are confirmed after review of the fitted configuration.