Site visit or bench evaluation
Request a site visit if the fault appears with the motor connected to the machine or changes with load, heat or cable position. For a send-in evaluation, include the resolver label, motor order code, drive model and fault history. Keep the original rotor and stator identified with the motor and ask for packing instructions before dispatch.
What a resolver bench test can show
Mitchell’s TI-5000JX manual covers generic resolver feedback on J12 and the TI-3011 breakout for waveform inspection. With verified winding connections, a compatible test setup can check that the indicated angle moves smoothly through one full cycle per revolution, both output envelopes vary correctly, and the signal level stays consistent as the shaft turns.
Mitchell lists a generic excitation range of 1–20 kHz and up to 8 V peak. Tamagawa’s 7 V RMS sine rating is about 9.9 V peak across the excitation pair. Use the generic setup for functional checks within its documented range and a rated excitation fixture for verification at the Tamagawa rating. Mitchell Generic Resolvers training chapter
Tamagawa TS2640N321E64 technical reference
Find the complete resolver part number
Look for TS2640N321E64 on the resolver label or the motor’s parts list. This is Tamagawa’s built-in size 21 Smartsyn with a separate rotor and stator. Record the whole type code and the motor order code before ordering either part.
| Model | Construction | Excitation | Rated speed |
|---|---|---|---|
| TS2640N321E64 | Frameless, separate rotor and stator | 7 V RMS AC, 10 kHz | 10,000 rpm |
| TS2641N11E64 | Hollow-shaft assembly with set-screw attachment | 7 V RMS AC, 10 kHz | 5,000 rpm |
Production and end-of-life status
Tamagawa lists TS2640N321E64 in its built-in Smartsyn range. Current production, lead time and end-of-life status require confirmation from Tamagawa or the motor maker. Checked 7 November 2026. Tamagawa model listing
TS2640N321E64 specifications
These figures apply to the TS2640N321E64. Confirm the allowable speed and operating conditions of the complete motor assembly separately.
| Parameter | Manufacturer specification |
|---|---|
| Construction | Size 21 built-in brushless resolver, 1X-BRX |
| Primary excitation | 7 V RMS AC at 10 kHz across R1–R2 |
| Winding outputs | Cosine on S1–S3, sine on S2–S4, Tamagawa +type convention |
| Transformation ratio | 0.5 ±5% |
| Electrical angle error | ±10 arcminutes maximum |
| Residual voltage | 20 mV RMS maximum |
| Signal phase shift | −5° ±10° |
| Primary AC impedance (Zro) | 100 + j140 Ω, ±15%. Use winding continuity for an isolated DC meter check. |
| Allowable speed | 10,000 rpm |
| Operating temperature | −55 to +150 °C in Tamagawa’s online model table |
| Mass | 0.22 ±0.10 kg |
Tamagawa built-in model specifications · Smartsyn catalogue 1507N9EJ (PDF)
How the rotor and stator fit the motor
The rotor locates on the motor shaft and the stationary resolver case seats in the motor housing. For this part, the drawing shows a Ø12.7 mm rotor bore, a Ø52.4 mm case diameter and a 1.1 ±0.25 mm axial mounting dimension between the indicated case and rotor faces. Use the drawing for fits and datum faces, and use the motor maker’s instructions for retention, fasteners and extraction.
With the machine isolated and the load secured, record the original seating, rotor-to-case orientation and lead route before disassembly. Inspect for rub marks, shifted seating, damaged leads or looseness. If either half moved, verify the mounting and commutation reference on the assembled motor. Tamagawa size 21 outline and mounting dimension, p. 8 (PDF)
Interface · How the resolver sends angle to the drive
The 1X brushless resolver measures absolute angle within one mechanical turn. The drive or feedback card sends an AC carrier to R1–R2. The rotor position changes how much of that carrier returns on the sine and cosine winding pairs. The receiver demodulates both returns, using their amplitudes and polarities to calculate the angle and quadrant, even at standstill.
One turn of the rotor produces one full cycle of the angle. With a 7 V RMS carrier and a nominal 0.5 ratio, the larger return can reach about 3.5 V RMS at its peak shaft position under the specified conditions. A low reading on one return at a single angle can be normal. Observe both channels over a controlled turn before diagnosing a missing output. Tamagawa resolver principle and winding diagrams, pp. 5–6 (PDF)
Verified winding leads and PG-RT3 terminals
These are Tamagawa’s resolver-side lead colors and the matching terminals on the Yaskawa PG-RT3 option card TB2. Motor-body plugs can have their own colors and pin numbering. Check the exact motor-end drawing before terminating the cable.
| Function | Resolver leads and colors | PG-RT3 TB2 |
|---|---|---|
| Excitation | R1 red/white · R2 yellow/white | R1 · R2 |
| Cosine return | S1 red · S3 black | S1 · S3 |
| Sine return | S2 yellow · S4 blue | S2 · S4 |
Tamagawa winding colors, Figure 1 (PDF) · Yaskawa PG-RT3 Figure 19 and Table 5, pp. 29–31 (PDF)
Cables inside the motor
Tamagawa’s outline shows factory flying leads, 26 AWG and at least 400 mm long. The motor manufacturer specifies the internal termination, connector and replacement harness. A universal motor-side cable part number is unconfirmed. Use the motor serial number and feedback option to order the correct loom. For PG-RT3 installations, follow Yaskawa’s shielded twisted-pair wiring and shield termination in Figure 19. Factory lead details in the outline (PDF)
Fault checks before replacing the resolver
- Isolate the machine first. Lock out motor power and the feedback supply, follow the drive’s discharge and verification procedure, and secure the shaft and load. Inspect the motor connector, lead exit and stator seating for damage or movement.
- Check the disconnected harness. Separate both ends from the resolver, drive and any sensor or electronics. Check continuity of every intended conductor and verify isolation between pairs and to shield or shell where the drawing shows no bond. Gently flex the isolated harness to find intermittent opens.
- Check the isolated windings. Use a low-energy ohmmeter to check R1–R2, S1–S3 and S2–S4. Compare the sine and cosine readings and look for an open pair, a short between pairs or a short to the frame. Tamagawa’s AC impedance is a different measurement from winding DC resistance. Use OEM resistance limits or a known-good identical resolver for comparison.
- Check excitation and both outputs. A qualified technician can use the approved fixture or drive test setup with motion controlled. Measure the AC carrier across R1–R2 with suitable bandwidth at 10 kHz. If the carrier is healthy, examine both return waveforms across their pairs. Missing excitation points first toward the option, harness or supply. An angle that jumps with a known-good harness calls for checking the winding signals, fit and drive receiver.
Documented application · Yaskawa PG-RT3
Yaskawa names TS2640N321E64 as a compatible resolver for the PG-RT3 motor feedback option. The installation manual lists compatible drive families including A1000, U1000, GA700 and GA800. Use the manual for the actual drive, option revision and control mode. Yaskawa PG-RT3 application and manual
Angle of alignment and where it is stored
The resolver’s mechanical zero is the reference of its sine/cosine pair. Commutation requires the motor’s rotor electrical reference as well. On this passive resolver the offset belongs to the motor and drive setup. Record the motor nameplate, original mounting orientation, feedback direction and the drive’s parameter backup before replacement.
For the documented Yaskawa PG-RT3 application, the manual identifies the motor nameplate Δθ as the reference for drive parameter E5-11 and directs technicians to the drive’s offset-tuning procedure when the resolver is replaced or rotation is changed. Use the exact drive and motor commissioning instructions. A qualified technician should verify phase order, feedback direction and electrical alignment on a secured assembly before enabling motion. Yaskawa PG-RT3 offset guidance in Table 7 (PDF) · Mitchell resolver alignment and bench reference
Drawings and manuals
- Tamagawa Smartsyn catalogue 1507N9EJ (PDF) for winding diagrams, ratings and the size 21 mounting outline.
- Yaskawa PG-RT3 installation manual TOBP C730600 87C (PDF) for option wiring and drive-side diagnostics.
- Mitchell TI-5000JX training manual for bench testing and commutation checks.