Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell describes comparing N110 serial and A/B counts using the supported Tamagawa profile. Confirm the exact harness and tester configuration before using TI-5000JX. Match any TI-3000JX setup to the full motor and actual feedback type independently.
Tamagawa TS5643N110 Serial and ABZ Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is TS5643N110. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| TS5643N110 | Ø35 mm class. Use the Tamagawa motor-journal drawing for the N110. | Serial absolute and separate 2048-period A/B with a Z index. |
| TS5643N164 | Matsushita variant discussed by Mitchell. Check the label and loom. | Mitchell identifies an application without Z. Confirm the specific build. |
| TS5643N151 | Denso variant discussed by Mitchell. Match full model. | Check serial and incremental outputs on the applicable drawing. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Absolute data | 11 bits within a turn and 13 bits of turn count (8192 turns) in the Tamagawa catalogue. |
| Incremental | 2048 periods/revolution with two phase outputs and one Z event per turn for N110. |
| Power | 5 V DC ±5% on N110 in the Tamagawa specification. |
| Mechanics | Ø35 mm reference class. The catalogue gives the recommended motor shaft and joint recess. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Use the N110 drawing to check the motor-journal and joint-recess dimensions, locating diameter, axial fit and space for the lead. Compare the position of the stator attachment and cable routing before changing the motor reference. Keep the encoder cover and connector clear of the rotor.
Interface and measuring method
The serial receiver reads binary absolute position and a turn word. The A/B tracks provide motion feedback separately, and Z indicates one reference per turn. Comparing the two paths across the same movement can identify a fault confined to the serial or incremental side. Check the configured edge-count convention before comparing numbers.
Verified wiring
Use the connection and system diagrams in the Tamagawa catalogue for N110. Confirm the fitted motor’s contact view and compare its labels with the catalogue conductors before probing.
| Contact or group | Function |
|---|---|
| Operating supply and return | 5 V supply and corresponding 0 V from the N110 connection table |
| RX pair | Serial data path. Read the complement symbols in the original diagram. |
| A/B and Z | Separate phase and reference outputs |
| Backup and reset | Apply the machine OEM preservation and recovery procedure. |
Cables inside the motor and at the machine
The Mitchell index lists TI-5703 with a 12-pin JST for a Matsushita/Tamagawa TS5643 branch. The N110 compatibility still needs the exact connector drawing. Trace the device pigtail and any PCB connector through to the motor outlet using the OEM harness part number.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Serial word changes and index never appears | Verify N110 label and continuity of the Z path. Compare with the applicable receiver input and the no-Z variant scope. |
| ABZ is clean but absolute turn count is lost | Inspect the backup path and serial status with the approved machine procedure. |
| Both signal paths drop under load | Check supply at the encoder, cable contact resistance and motor-end connector retention. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the exact motor order and N110 label to match the application. Mitchell documents TS5643-family feedback in several motor brands. The published Matsushita cable branch is useful when its connector and fitted encoder agree with the drawing.
Angle of alignment and commissioning
Capture the original motor and machine reference, backup status and applicable encoder data before removal. After mounting, confirm count direction, index behavior and the OEM alignment or reference routine. Recheck both paths before returning the axis to operation.
Drawings, pin maps and manuals
- Main technical PDF. Tamagawa T12-1228N57, manufacturer catalogue mirror. TS5643N110 dimensions, specification and connection table around printed pages 39–41.
- Manufacturer reference. Manufacturer regional multiturn encoder catalogue. N110-specific information is in the technical PDF.
- Mitchell Tamagawa serial guide. TS5643N110 ABZ and serial behavior and related variants.
- Mitchell Matsushita motors. Motor and encoder label identification.
- Mitchell cable index PDF. TI-5703 TS5643-family lead.