What specialist testing can show
TI-5000JX bench. TI-5000JX TS5667 serial and count checks using the verified TI-5066 branch or another exact matched lead.
TI-3000JX motor run. Mitchell lists TS5667 under Generic Tamagawa run additions. Confirm the exact motor and fixture.
Starting lead. TI-5066 on the documented Matsushita / Toshiba branch. Confirm the actual connector.
Tamagawa TS5667 17-Bit SmartABS Serial Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| TS5667 / SA48 | Mitchell’s 17-bit SmartABS row. Its supported-types chart associates TI-5066 with Matsushita / Toshiba. |
| TS5647 | 16-bit family covered by TCG198. Read the exact encoder identification before setting the position scale. |
| TS5669N221 | Mitchell reports matching electronics and ID for this comparison. Check physical fit and full OEM order separately. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Within-turn position | 17 bits, or 131,072 possible positions per revolution, on the TS5667. |
| Turn field | 16 bits in the documented format. Check the separate fields when the combined display reaches its limit. |
| Electrical path | Serial data, supply and retention on the documented SmartABS branch. Use the fitted connector drawing. |
Interface and measuring method
SmartABS returns the position and status digitally. A healthy within-turn count can coexist with a problem in retained turns. Check the encoder ID and data fields before interpreting a large combined number.
Mounting and fit
Record the fitted TS5667 suffix, stator restraint, shaft engagement and cable exit. The same electrical selection can appear in a different package. Use the exact drawing for fit and fasteners.
Wiring and connector scope
Trace supply, return, serial data and retention by the actual connector view. TI-5066 is documented for the cited motor branch. The Mitchell cable index also names a separate 17-contact MS TS5667 connection. Verify which plug is fitted.
Internal motor and machine cables
Use the complete motor and controller orders for the machine cable. Record the internal harness separately and retain its connector orientation, latch and shield path.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Angle reads and turn data is wrong | Check the separate turn field and retention circuit before judging the encoder. |
| Data looks clipped at large positions | Check the tester’s combined-count display limit and compare the separate fields. |
| Encoder ID matches and the replacement will not fit | Verify the full suffix, motor order, shaft interface and actual connector. |
Angle of alignment and commissioning
Save the incoming absolute reference and turn data before removal. Use the fitted motor procedure for recommissioning and verify rollover, direction and commutation as applicable.
Motor and drive applications
Matsushita / Toshiba reference in the supported-types table
Obtain full fitted suffix, motor order, mechanical drawing, correct lead and original retention information.
Related SpareFaber guides
Drawings, pin maps and manuals
- Tamagawa Serial Encoders. TS5667 and supported-types table
- Mitchell Tamagawa supported-types table. TS5667 row, 17-bit count, TI-5066 and motor references.
- Mitchell test cable index. Check the exact TS5667 connector and cable listing.
- Mitchell Athena new features. Generic Tamagawa run support scope.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.