Site visit or send-in evaluation
Feedback diagnosis, Installation, Alignment. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
A resolver fixture can check winding integrity, transformation ratio, symmetry, phase and repeatability with approved excitation and load. Determine whether the exact resolver, wiring and excitation fit the chosen tester before assigning a Mitchell lead or run procedure.
TE Connectivity V23401-S1001-B101 2-1393047-5 Size-15 Hollow-Shaft Resolver technical reference
Find your part number
Use the full label and suffix. The main reference is 2-1393047-5. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
Manufacturer device order code
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 2-1393047-5 · V23401-S1001-B101 | Size-15 hollow-shaft resolver. Match the dimensioned rotor, stator and lead exit. | One pole pair, passive excitation and two secondary windings. |
| 2367254-1 · V23401-T2715-B101 | Different size-21 resolver assembly. | Separate two-pole-pair guide. Match mechanical and electrical requirements individually. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Resolver type | Size 15, one pole pair, TE item 2-1393047-5. |
| Reference test | TE sheet specifies 7.0 V RMS input, 10 kHz typical. Use the approved receiver and specified test conditions. |
| Transformation ratio | Nominal 0.50 in the exact data sheet. |
| Output | Two AC secondary voltages whose amplitudes depend on rotor angle. |
| Mechanical fit | See the exact revision D2 customer drawing for bore, stator pilot and mounting. |
The table identifies the assembly each value applies to. Main technical PDF.
Mounting and fit
Measure the motor shaft and resolver seating features from the exact D2 drawing. Protect the windings and keep the rotor and stator from touching. Compare cable exit, axial position and original witness marks before making adjustments.
Interface and measuring method
The drive supplies an AC excitation to the primary. The two secondaries return carrier signals scaled by rotor angle. A resolver-to-digital converter uses their ratio and phase to calculate position. One pole pair gives one electrical cycle per mechanical revolution.
Verified wiring
The following winding names are from the TE data sheet for V23401-S1001-B101. Use the customer drawing and equipment wiring for lead identification.
| Contact or group | Function |
|---|---|
| R1–R2 | Excitation winding. |
| S1–S3 | Cosine secondary under TE’s stated viewing and polarity convention. |
| S2–S4 | Sine secondary under the same convention. |
Cables inside the motor and at the machine
Use the fitted equipment drawing to identify winding pairs, polarity, shield and any machine connector. The TE drawing covers the resolver assembly. It does not establish a specific motor loom or tester cable.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No usable output from either secondary | Check whether the approved receiver is supplying excitation. Inspect the disconnected harness and compare primary and secondary winding resistance with a known reference for this exact part. |
| Only one track is low or distorted | Check the corresponding winding, pair wiring, load and rotor/stator seating. Compare both tracks with controlled rotation on a suitable fixture. |
| Angle reads but commutation is wrong | Verify phase convention, polarity and rotor-to-motor alignment against the OEM procedure. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare the documented supply or excitation under the specified load. Use the approved receiver or instrument to observe the appropriate data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Use the exact TE item for assemblies whose drawing specifies this rotor and stator. The public data sheet does not identify a universal motor or drive. Record the machine, motor and resolver receiver model for service.
Angle of alignment and commissioning
TE defines an electrical zero by the S2–S4 null and S1–S3 phase relationship in the exact sheet. The installed motor commutation offset still comes from the motor builder’s procedure. Record the original reference before removing the resolver.
Drawings, pin maps and manuals
- Main technical PDF. Exact TE electrical data sheet with winding functions, test conditions and reference convention. Use the separate drawing for fit.
- Manufacturer reference. Match the exact order code or the identified motor option.
- TE dimensioned customer drawing D2. Check rotor, stator, mounting and lead details for item 2-1393047-5.
- TE size-21 comparison. Related technology with different size and pole count.