Site visit or send-in evaluation
We can trace SSI clock and data to the receiver and check how the reported position and alarms change through the motor's usable travel. Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
Mitchell documents the 319-663 SSI profile with TI-5000JX and an external bench supply. Use the approved TI-5636 drawing and setup to confirm the supply, signal reference and supported clock/data connection. Bench checks can compare position, turns and alarm response. Verify TI-3000JX motor run support independently.
Unico 319-663 SSI Absolute Motor Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 319-663. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 319-663 | Unico label. Mitchell lists an MTS MPM application and 12-pin M23 test connection. | Mitchell describes 24-bit Gray position plus an alarm bit. Check the actual connector key and decoder setup. |
| Hengstler Type RA 58 | Mitchell's comparison family. The original Unico mechanical drawing and Hengstler order suffix are still needed. | SSI resemblance is a research lead. Establish fit and frame configuration for an exact replacement. |
Production and end-of-life status
Mitchell’s technical references identify the installed device. Confirm current Unico service availability or supersession from the complete OEM motor order.
Specifications
| Parameter | Value and scope |
|---|---|
| Interface | Synchronous Serial Interface (SSI), Mitchell’s 319-663 description |
| Position word | 24 Gray-coded bits, 12 for turns and 12 for angle within a turn, followed by an alarm bit |
| Supply | 10 to 30 V according to Mitchell’s test note. Confirm the motor/OEM specification. |
| Motor connection in the Mitchell index | MTS MPM, TI-5636, 12-pin M23 |
| Exact fit data to obtain | Shaft, locator, stator mounting, lead orientation and internal loom |
The table identifies the assembly each value applies to.
Mounting and fit
Record the exact MPM motor label, serial and feedback tag before disturbing the encoder. On an isolated assembly, document the coupling or shaft retention, housing mount and any adjustment marks. Look for signs of slip, excessive play or strain on the encoder cable.
The public test note does not give the 319-663 mating dimensions. Obtain the motor's feedback drawing before tightening a fastener or substituting a shaft or coupling.
Interface and measuring method
The controller issues the clock and the encoder shifts the Gray-coded position word back. Turn and within-turn bits travel in the same word, followed by a status bit in the documented Mitchell setup. Wrong bit count, Gray decoding or direction can create apparent jumps even when the wiring carries valid frames.
Verified wiring
The Mitchell connection section points to the TI-5636 diagram. It describes a 12-pin connector with a different pin rotation from the visually similar Indramat type. Match the key and numbered cavities to the supplied motor-side drawing and the plug view.
| Circuit | Purpose |
|---|---|
| Clock + / − | Receiver timing pair |
| Data + / − | Encoder response pair |
| Supply and signal return | Separate power input and reference, sized and connected per the motor and tester requirements. |
| Direction, shell and screen | Compare the drive and connector drawing before changing any bond or direction circuit. |
Cables inside the motor and at the machine
TI-5636 is the Mitchell test harness reference. The index lists it by number, while the support article carries an availability caveat. Obtain the current cable drawing and availability from Mitchell. Use the full MPM motor order and connector details to identify the internal loom and machine cable.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| Position jumps at a repeatable bit boundary | Check Gray coding, word length, alarm bit handling and receiver frame interpretation. |
| No reply or frequent read failures | Check loaded supply and return. Verify clock at the encoder and returned data at the drive with the approved interface. |
| Fault changes with cable position | Isolate the harness and test conductor pairs, crimp retention and intended shield bonds. |
| Angle error starts after disassembly | Check shaft or coupling retention and the documented drive reference or motor commutation procedure. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
Mitchell ties 319-663 to the MTS MPM family. Identify the exact MPM model and drive before assigning a cable or setup. The resemblance to the RA 58 family is a lead for further investigation.
Angle of alignment and commissioning
Record the original mechanical reference, counting direction and controller offsets. The SSI frame reports position and status. Obtain the motor's commutation and datum procedure for the installed encoder and drive before moving the mounting. After replacement, verify direction and reference with the machine in its approved commissioning condition.
Drawings, pin maps and manuals
- Mitchell Unico SSI service article. Model label, frame structure, supply and test cable guidance.
- Mitchell manufacturer cable index. MTS MPM / Unico 319-663 entry for TI-5636.
These references describe the application and test route. The OEM encoder datasheet is still needed.