What specialist testing can show
TI-5000JX bench. Read the reported ID and verify a 17-bit incremental serial count with the fitted connection.
TI-3000JX motor run. Match the actual motor and phase reference to the supported Sigma run selection.
Starting lead. Select the Sigma-II or Sigma-III fixture by the complete motor order and connector.
Yaskawa UTTIH-B17 17-Bit Incremental Serial Encoder technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| UTTIH-B17 · ID C | 17-bit incremental serial. Select the fitted Sigma motor connection and tester profile. |
| UTSSH-B16 · ID B | 16-bit incremental serial. Separate profile and count width. |
| UTSAH-B17 · ID 2 or 5 | 17-bit absolute serial in Mitchell’s table. Verify the original controller and retention requirements. |
| UTTIH-B20 · ID D | 20-bit incremental serial, with its own supported family and profile. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| Position field | 17 bits, corresponding to 131,072 positions within a turn for the listed encoder profile. |
| Interface | Yaskawa incremental position carried by serial communication. |
| OEM motor families | Mitchell lists Sigma-II and Sigma-III. Match the full motor order for the connector and supported run setup. |
Interface and measuring method
The encoder exchanges position with the Yaskawa receiver over its serial link. Incremental here describes the device’s position/reference behavior. Diagnose this link as serial feedback even when the drive reports an incremental count.
Mounting and fit
Obtain the fitted motor service drawing. Record the encoder label, shaft reference, mounting seat and harness routing before disturbing the rear assembly. A Sigma series identifier alone leaves the rear assembly and connector open.
Wiring and connector scope
Use the actual Sigma-II or Sigma-III motor connector map and approved supply and return. Verify the pin view at both the motor and drive. Capture the tester ID after confirming a matched connection.
Internal motor and machine cables
Identify the machine encoder cable from the motor and SERVOPACK orders. Mitchell’s Sigma family lead lists cover several plugs. Select by the fitted connector and wiring and record a different factory loom separately.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| 17-bit reading with a configuration error | Check ID C versus the absolute ID and the actual drive feedback mode. |
| Serial data drops when the connector moves | Inspect lock, pins and cable strain then continuity-check the isolated harness. |
| Feedback stable but motor trips at enable | Compare motor phase reference, polarity and commissioning parameters. |
Angle of alignment and commissioning
Record direction and the motor electrical reference. Confirm the fitted motor procedure and any original configuration before replacement. Save the baseline and verify at a known mechanical position after fitting.
Motor and drive applications
Sigma-II and Sigma-III applications with fitted UTTIH-B17
Separate UTTIH-B17 ID C from UTSSH-B16 ID B and UTSAH-B17 absolute.
Related SpareFaber guides
Drawings, pin maps and manuals
- Yaskawa Serial Encoder Identification. Encoder identification table, ID C / 17 bit INC / UTTIH-B17
- Yaskawa Sigma-II SGM / SGDM user manual. Supplementary reference for the stated model or setup.
- Yaskawa Serial Encoder Testing. Reference for the fitted feedback or motor option.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation