What specialist testing can show
TI-5000JX bench. Mitchell documents the M2L SRM branch and TI-5064 motor-side checks. Verify the fitted supply and connector.
TI-3000JX motor run. Confirm the exact motor, drive and supported run setup before operation.
Starting lead. TI-5064 for the documented high-resolution 1326AB motor-side arrangement. Module TI-5104 on the verified HIPERFACE setup.
Allen-Bradley 1326AB M2L Stegmann SRM50/60 Multiturn HIPERFACE Feedback technical reference
Find your part number
Compare the fitted feedback label, complete motor order and connector. A motor order and an encoder MPN identify different items.
| ID or order | How to identify it |
|---|---|
| 1326AB-B…-M2L | Multiturn SRM50/60 HIPERFACE option in Mitchell’s order table. Confirm the fitted encoder label. |
| 1326AB-B…-S2L | Separate singleturn SRS50/60 option. Match the full motor order and encoder suffix. |
| 1326AB-B…-21 | Resolver branch in the same table. Verify the feedback family before wiring. |
Production and end-of-life status
Confirm orderability and any replacement with the manufacturer against the full fitted ID. The linked documents identify the documented setup.
Specifications
| Parameter | Verified scope |
|---|---|
| M2L format | Multiturn classic HIPERFACE on the documented SRM50/60 setup. |
| Test point | TI-5064 at the verified motor connector, with the cover and its restraint in place. |
| Motor memory | Mitchell documents Allen-Bradley motor data and alignment values in the applicable encoder memory. |
Interface and measuring method
The drive gets absolute position and motor data over the serial path and reads sine and cosine for movement. A serial reply and a sound analogue signal provide separate evidence. Verify the installed cover and motor-side harness during the final check.
Mounting and fit
Record the actual cover, stator restraint and encoder seat. Mitchell warns that removing the cover can leave the encoder body free to move on this motor arrangement. Use the OEM fitting instructions and verify the final position with the cover secured.
Wiring and connector scope
Use the high-resolution 1326AB motor connection in the Rockwell manual. Verify TI-5064 at the motor-side plug and identify power, analogue, data and temperature paths by function.
Internal motor and machine cables
Use the actual 1326AB and 1394 order codes for the machine cable. Confirm the internal encoder lead and cover routing separately. TI-5064 tests through the motor harness on the documented connector.
Fault checks
Use the site’s isolation procedure before opening a connector or checking resistance. Secure the load against motion, lock out relevant energy sources, wait the specified discharge time and have a qualified technician verify isolation. Follow the OEM procedure for any retention battery.
What can I check on the machine?
Disconnect the harness at both ends. Check end-to-end continuity against the exact drawing, then check for unintended shorts between conductors and to the shell or shield. Compare against the documented shield bonds. Inspect pins, keying, debris, moisture and latch engagement. Check clamps or fasteners only where accessible under the approved procedure.
Use only the OEM-approved powered check and a suitable breakout. A qualified technician can compare the voltage across the specified supply and return with the model’s limits under the stated test conditions. A multimeter can check supply health. Signal integrity and communications require the appropriate signal test.
| Symptom | What to verify |
|---|---|
| Alignment changes when the cover is fitted | Recheck the body restraint and verify the final angle through the motor plug. |
| Direct feedback works and motor-side testing fails | Trace the internal loom and connector before replacing the encoder. |
| Drive rejects the replacement | Confirm M2L turn mode, exact SRM suffix and matching motor data. |
Angle of alignment and commissioning
Record incoming memory and measured reference. After fitting and securing the cover, have a qualified specialist verify the actual alignment and position from the motor side.
Motor and drive applications
Allen-Bradley 1326AB-B…-M2L
Obtain full 1326AB order, fitted SRM suffix, exact cover and internal cable details.
Related SpareFaber guides
Drawings, pin maps and manuals
- Allen Bradley (Reliance, Electrocraft) Motors. 1326AB order-code table and motor-side testing
- Rockwell 1394 SERCOS installation manual 1394-IN024. M2L/S2L high-resolution 1326AB connection and system drawings.
- Mitchell 1326AB feedback code table. Resolver, singleturn and multiturn order options.
Questions
Can I use a similar label as a replacement?
Compare the interface, mechanical fit, connector, data or commutation requirements and OEM option before choosing a substitute. The ID table gives the useful distinctions for this guide.
What information helps with a diagnosis?
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.
Site visit or send-in evaluation
Send the encoder and motor labels, drive model, alarm history and both connector views. Say whether the problem began after cable work, encoder replacement or a drive change. We can confirm visit scope or send-in evaluation and timing from those details.