Site visit or send-in evaluation
Share the full feedback ID, machine or motor order code, drive or controller model and fault history. Send photos of the label, mating connectors and mounting. Tell us if the fault followed a repair, cable change or controller replacement. Request a UAE site visit or bench evaluation.
What specialist testing can show
With the matched cable and a compatible EnDat22 receiver, check position, direction, turn count and available diagnostic registers. HEIDENHAIN documents mounting diagnostics for modular inductive encoders. Confirm the exact Mitchell profile and adapter before bench work and the complete motor setup before any TI-3000JX run test.
HEIDENHAIN EQI 1131 EnDat Encoder technical reference
Find your part number
Use the full label and suffix. The main reference is 1164813-02. The related rows identify distinct configurations or label codes. Match the actual assembly before substituting.
| Exact ID or order code | Mechanical configuration | Electrical or service distinction |
|---|---|---|
| 1164813-02 | EQI 1131, 70F synchro flange with 2.30 mm centering collar and Ø6 × 4 mm blind bore. | EnDat22, 19-bit singleturn and 12-bit multiturn. D608296, straight axial 15-pin. |
| 1164811-02 | EQI 1131 functional-safety build with 1.7 mm collar and 2 × 180° axial clamping. | EnDat22, same listed position range. Separate safety and mating documentation. |
| 1164812-02 | ECI 1119 singleturn build with the listed 70F geometry. | EnDat22, 19 bits per turn. No multiturn range in the catalogue. |
| 1164815-02 | EQI 1130 with the listed 70F geometry. | EnDat01 plus 16 periods of 1 Vpp per turn. 4.75–10 V DC and 18-bit singleturn. |
Production and end-of-life status
The listed technical records identify this model. Confirm current production and orderability for the exact suffix with the manufacturer when sourcing a replacement.
Specifications
| Parameter | Value and scope |
|---|---|
| Position | 524,288 positions per turn and 4,096 turns. Absolute binary EnDat22. |
| Supply and load | 3.6–14 V DC at the encoder. 115 mA typical at 5 V, per the 70F EQI 1131 column. |
| Interface timing | Clock frequency up to 16 MHz and calculation time up to 5 µs per 1270494. Use the drive and cable limits for the installation. |
| Component limits | Up to 12,000 rpm mechanically for the listed 70F EQI 1131. −40 to +110 °C, IP00. |
| Mating features | Ø36.83 mm locating flange, collar 2.30 mm long. Ø6 mm blind hollow shaft, 4 mm deep. |
The values in this table apply to the reference build unless a row identifies another scope. Main technical PDF.
Mounting and fit
The motor bearings establish the rotor position. Clamp the encoder rotor axially on the mating shaft and secure the stator via the 70F flange. Check the shoulder, register, axial seating and cable clearance after bearing work. Document 1270494 identifies the M3 × 25 central screw kit 202264-86 and flange kits 1264352-01 and -02 for this geometry. Use the exact motor assembly drawing for tightening and gap checks.
Interface and measuring method
The drive issues commands on CLOCK and reads binary position and status on the bidirectional DATA pair. The 70F EQI 1131 sends multiturn position digitally and has no analog 1 Vpp output in this configuration. Compare the singleturn and turn count through one slow controlled revolution. Loss of serial communication calls for a supply, sense and pair check before a position or commutation diagnosis.
Verified wiring
This is the encoder-side D608296 PCB connector assignment in 1270494, PDF page 6. Use the mating drawing to identify numbered contacts. The M12 column is only for the documented HEIDENHAIN adapter and must be matched to the installed loom.
| Function | 15-pin PCB | 8-pin M12 adapter |
|---|---|---|
| Supply / return | 13 / 14 | 8 / 5 |
| Supply sense / return sense | 11 / 12 | 2 / 1 |
| DATA / inverted DATA | 7 / 8 | 3 / 4 |
| CLOCK / inverted CLOCK | 9 / 10 | 7 / 6 |
| External temperature sensor | 5 / 6 on applicable internal adapters | Separate leads where supplied |
Cables inside the motor and at the machine
For the 70F EnDat22 build HEIDENHAIN lists 804201-xx from 15-pin PCB to straight 8-pin M12 flange socket, 1119952-xx for that arrangement with temperature sensor leads, and 1119958-xx for open termination with sensor leads. These are encoder-side options. Check exact length, sensor routing and OEM bulkhead before ordering. Use the connector removal aid 1075573-01 where specified.
Fault checks
External checks. Record the exact label, alarm, drive status and when the fault occurs. Look for visible plug damage, contamination, cable strain and looseness without opening a live assembly.
Isolation before internal work. Follow your site’s lockout procedure. Secure the load against movement, isolate all motor, drive and separate feedback supplies, allow the specified discharge time and verify absence of voltage. A qualified technician should perform internal and electrical checks. Unplug or reconnect only with the applicable circuits safely de-energized.
Harness continuity. Check resistance only on a harness you can disconnect from both the device and the receiver. Compare with shorted meter leads, flex gently at strain reliefs, and test for unintended shorts between conductors and to the shield. Use the schematic to recognize intended bonds. Keep resistance and insulation testers away from connected electronics.
| Observation | What to verify |
|---|---|
| No EnDat response | Use the exact pin map to trace supply, return and the two pairs through the loom. Identify any sense links before measuring. |
| Position jumps after bearing work | Check mounting seating and the approved EnDat mounting diagnostics. Then compare with a known-good receiver or harness. |
| Position smooth, motor faults on enable | Check drive feedback selection and the motor-specific electrical reference. Hold the machine out of service until commissioning checks pass. |
Powered checks. A qualified technician can fit an approved breakout while de-energized, secure motion, and compare documented supply and return at both ends under the specified load. Use the approved receiver or instrument to observe data or signal pairs. Return to an isolated state before changing connections.
Motor and drive applications
The 70F modular family is specified for servo drives. Identify the actual OEM motor and drive option before applying connector, temperature-sensor or safety rules. The related ECI 1118 guide covers a different singleturn build. ECI 1118 guide.
Angle of alignment and commissioning
Verify rotor/stator fit and run the documented mounting diagnostics for the exact assembly. For the electrical reference, save the original motor's permitted encoder or drive data before removal. Restore and read back only per the OEM procedure on a compatible replacement for that motor. A valid EnDat response alone cannot establish commutation alignment.
Drawings, pin maps and manuals
- Main technical PDF. Start with the exact type or variant marked in the guide.
- Manufacturer or exact product reference. Use the order code and select the applicable downloads.
- 70F mounting and accessories. The assembly and hardware options.
- Related safety model. Compare the flange and approved safety documentation.
- Mitchell training index. See HEIDENHAIN serial encoders for general test setup.